As indoor smoking bans have become widely adopted, some U.S. communities are considering restricting smoking outdoors, creating a need for measurements of air pollution near smokers outdoors. Personal exposure experiments were conducted with four to five participants at six sidewalk bus stops located 1.5–3.3 m from the curb of two heavily traveled California arterial highways with 3300–5100 vehicles per hour. At each bus stop, a smoker in the group smoked a cigarette. Gravimetrically calibrated continuous monitors were used to measure fine particle concentrations (aerodynamic diameter ≤2.5 µm; PM2.5) in the breathing zones (within 0.2 m from the nose and mouth) of each participant. At each bus stop, ultrafine particles (UFP), wind speed, temperature, relative humidity, and traffic counts were also measured. For 13 cigarette experiments, the mean PM2.5 personal exposure of the nonsmoker seated 0.5 m from the smoker during a 5-min cigarette ranged from 15 to 153 µg/m3. Of four persons seated on the bench, the smoker received the highest PM2.5 breathing-zone exposure of 192 µg/m3. There was a strong proximity effect: nonsmokers at distances 0.5, 1.0, and 1.5 m from the smoker received mean PM2.5 personal exposures of 59, 40, and 28 µg/m3, respectively, compared with a background level of 1.7 µg/m3. Like the PM2.5 concentrations, UFP concentrations measured 0.5 m from the smoker increased abruptly when a cigarette started and decreased when the cigarette ended, averaging 44,500 particles/cm3 compared with the background level of 7200 particles/cm3. During nonsmoking periods, the UFP background concentrations showed occasional peaks due to traffic, whereas PM2.5 background concentrations were extremely low. The results indicate that a single cigarette smoked outdoors at a bus stop can cause PM2.5 and UFP concentrations near the smoker that are 16–35 and 6.2 times, respectively, higher than the background concentrations due to cars and trucks on an adjacent arterial highway.
Implications: Rules banning smoking indoors have been widely adopted in the United States and in many countries. Some communities are considering smoking bans that would apply to outdoor locations. Although many measurements are available of pollutant concentrations from secondhand smoke at indoor locations, few measurements are available of exposure to secondhand smoke outdoors. This study provides new data on exposure to fine and ultrafine particles from secondhand smoke near a smoker outdoors. The levels are compared with the exposure measured next to a highway. The findings are important for policies that might be developed for reducing exposure to secondhand smoke outdoors.相似文献
Summary. Benzoic acid is a known stimulant of olfactory receptor cells in trichoid sensilla on the antennae of adult females of Bombyx mori. Exposure of freshly excised antennae, from B. mori females and males, to vapours of [14C]-benzoic acid revealed that the adsorbed acid is rapidly metabolized (15% conversion in 10 s), suggesting the presence of
a highly active enzymatic system. The major product could be identified as N-benzoylserine by use of [2H5]-benzoic acid, and mass spectrometry linked to a gas chromatograph (GC-MS) or a liquid chromatograph (LC-MS), for analysis
of the metabolites. The conjugation of benzoic acid with an amino acid apparently represents a novel mode for the rapid deactivation
of odorant molecules.
Received 26 March 2001. 相似文献
Personal exposure to air pollutants can be substantially higher in close proximity to an active source due to non-instantaneous mixing of emissions. The research presented in this paper quantifies this proximity effect for a non-buoyant source in 2 naturally ventilated homes in Northern California (CA), assessing its spatial and temporal variation and the influence of factors such as ventilation rate on its magnitude. To quantify how proximity to residential sources of indoor air pollutants affects human exposure, we performed 16 separate monitoring experiments in the living rooms of two detached single-family homes. CO (as a tracer gas) was released from a point source in the center of the room at a controlled emission rate for 5-12 h per experiment, while an array of 30-37 real-time monitors simultaneously measured CO concentrations with 15 s time resolution at radial distances ranging from 0.25-5 m under a range of ventilation conditions. Concentrations measured in close proximity (within 1 m) to the source were highly variable, with 5 min averages that typically varied by >100-fold. This variability was due to short-duration (<1 min) pollutant concentration peaks ("microplumes") that were frequently recorded in close proximity to the source. We decomposed the random microplume component from the total concentrations by subtracting predicted concentrations that assumed uniform, instantaneous mixing within the room and found that these microplumes can be modeled using a 3-parameter lognormal distribution. Average concentrations measured within 0.25 m of the source were 6-20 times as high as the predicted well-mixed concentrations. 相似文献
The Fourth International Conference on Fluidized Bed Combustion (FBC) was held at The MITRE Corporation in McLean, VA, December 9 to 11, 1975. With attendees from Great Britain, West Germany, Japan, Canada, and Sweden, the conference apparently fulfilled its international scope and intent. The objectives of the conference were to review the current state of technology in FBC, to promote technical information exchange on FBC and related areas, and to generate a useful technical information base for further FBC development. Throughout the conference, the goal of commercialization was repeatedly emphasized. Sponsored by the U.S. Energy Research and Development Administration (ERDA) and coordinated by MITRE, this meeting was the most comprehensive event in the seven year series of conferences on this subject according to attendees. ERDA, the government’s lead agency in FBC technology development, is the principal sponsor and coordinator of the National Fluidized Bed Combustion Program with the goal of advancing the commercialization time frame for FBC. Prior conferences in this series were hosted by the Environmental Protection Agency (EPA) at about two year intervals at Hueston Woods, Ohio. The last EPA conference was held in October 1972. 相似文献
Residential interior door positions influence the pollutant concentrations that result from short-term indoor sources, such as cigarettes, candles, and incense. To elucidate this influence, we reviewed past studies and conducted new experiments in three residences: a single-story 714 m3 ranch-style house, a 510 m3 two-story split-level house, and a 200 m3 two-story house. During the experiments, we released sulfur hexafluoride or carbon monoxide tracer gas over short periods (≤30 min) and measured concentrations in the source room and at least one other (receptor) room for various interior door opening positions. We found that closing a door between rooms effectively prevented transport of air pollutants, reducing the average concentration in the receptor room relative to the source room by 57–100% over exposure periods of 1–8 h. When intervening doors were partially or fully open, the reduction in average concentrations ranged from 3% to 99%, varying as a function of door opening width and the distance between source and receptor rooms. 相似文献
This study examines: (1) the impact of two methods of giving screening results on health behaviour and beliefs, evaluated in a randomized controlled trial. (2) The association between uptake of screening and health risk behaviours and beliefs. Two methods of feedback of screening results were given: simple informational feedback, and more extensive feedback, including target-setting and a written contract. At six month follow-up, those who received simple informational feedback had lost less weight and had increased their exercise less than those who received more extensive feedback. Attenders believed more strongly in the relationship between lifestyle and health, perceived themselves as less healthy than others and scored higher on the GHQ than staff who did not attend for screening. These results suggest that belief in the effectiveness of lifestyle change in promoting health, and anxiety about health, can influence uptake of screening. Second, the method of presenting screening results can influence the impact of screening on subsequent behaviour change. 相似文献
Safety climate, the objective measurement of attitudes and perceptions toward Occupational Health & Safety (OH&S) issues, has been largely ignored and measures such as lost time and frequency rate have been used to determine the efficacy of OH&S programs. Yet, it is clear that measuring the precursors of accidents identified in a safety climate analysis provides a powerful proactive management tool. This paper reports on safety climate factors found in clerical and service organizations in Australia. Concurrent validity studies are reported. In contradistinction to published studies, it is argued that safety climate factors are not stable across organizations. The significance of this for planning and assessing the efficacy of OH&S programs is discussed. It is concluded that although safety climate factors are not stable, the safety climate factor pattern identified in organizations provides a powerful management tool for designing OH&S programs. 相似文献
The environmental impact of loss of natural stream and riparian habitat is of concern throughout the United States and Europe.
Environmental impacts related to such activities as channelization of and levee construction along streams and rivers are
particularly apparent in the Midwestern United States. The objective of the research presented here was to delineate the extent,
relative degree of impact, and implications for management of channelization and levee construction along watercourses located
in the state of Illinois. According to records maintained through the Illinois Streams Information System data base (Illinois
Department of Conservation), nearly 25% of surface water resources in the state have been modified directly by channelization
and/or levee construction. Reviews of agency records, elaboration of case histories, interviews with agency personnel, and
inspections of impacted sites indicated that these alterations have occurred without the benefit of effective mitigation.
Although permit records may provide suggestions for mitigation to be incorporated in the design of a particular project, permits
issued generally do not require even minimal instream habitat and bank stabilization efforts in conjunction with channel alteration.
Information derived from policy and case study analyses suggests that institutional constraints, rather than lack of particular
understanding about mitigation, provide major barriers to protecting the state's surface water resources in terms of regulatory
review, policy interpretation and implementation, and project evaluation. Recommendations for environmental management efforts
regarding these and similar channel alterations are elaborated from these findings. 相似文献