首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   19篇
  免费   0篇
  国内免费   4篇
废物处理   1篇
环保管理   1篇
综合类   5篇
基础理论   4篇
污染及防治   4篇
评价与监测   6篇
社会与环境   2篇
  2022年   1篇
  2020年   1篇
  2018年   1篇
  2017年   3篇
  2016年   1篇
  2015年   2篇
  2014年   1篇
  2013年   2篇
  2012年   2篇
  2010年   2篇
  2009年   1篇
  2008年   3篇
  2006年   1篇
  2005年   1篇
  2002年   1篇
排序方式: 共有23条查询结果,搜索用时 453 毫秒
11.
To examine the state of pollution of Bizerte Lagoon which is exposed to intense anthropogenic pressure, two sediment cores were taken at two sites, one undergoes the dual effects of both marine waters arriving from the Mediterranean Sea through the Channel, and also of freshwater from the Tinja River; the other core is located at the center of the lagoon where water depth is maximal (12 m). Heavy metal concentrations in the two cores were assessed, with calculated enrichment factors and geo-accumulation indexes. Core sediments were also studied for chemical speciation and their monosulfide contents were measured. Results from enrichment factors and geo-accumulation indexes show an accumulation of Cd, Zn, Cr, and Pb, while chemical speciation revealed a risk only from Cd and Mn. Comparison of sequential extraction values with those of acid volatile sulfides revealed that non-toxic effects may be caused by any of the studied metals in the sediment.  相似文献   
12.
Yassaa N  Cecinato A 《Chemosphere》2005,60(11):1660-1666
The absolute contents and relative distributions of organic aerosols [n-alkanes, n-alkanoic and n-alkenoic acids, n-alkan-2-ones and polycyclic aromatic hydrocarbons (PAH)] were determined in torched gases emitted during the crude oil extraction and in the free atmosphere of the Hassi-Messaoud city (Algeria). Monocarboxylic acids, both saturated and monounsaturated (from 9802 to 20 057 ng m−3), accounted for the major fraction of the total particulate organic matter identified both in torch exhaust and atmospheric particulate. n-Alkanes were also abundant both in the direct emission (from 460 to 632 ng m−3) and city atmosphere (462 ng m−3) and displayed a peculiar fingerprint characterised by the presence of a set of branched congeners around even carbon-numbered homologues and a strong even-to-odd predominance along the whole carbon number range (C16–C34). Whilst n-alkan-2-ones were absent in the city and poor in smokes emitted from the torches (from 31 to 42 ng m−3), PAH were present at low extents in all sites (from 18 to 65 ng m−3). The incomplete thermal combustion of torched crude oil was very likely the main source of these particle-bound organic constituents in the city and its surrounding region.  相似文献   
13.
Lower carbonyls and n-alkanals from C5 to C10 were measured from late autumn 2000 to summer 2001 in two urban areas in the Algerian territory: Algiers and Ouargla. They were collected on silica cartridges coated with dinitrophenylhydrazine (DNPH) and pentafluorophenylhydrazine (PFPH), which were analysed by HPLC-UV and high-resolution GC-MS. respectively. The two methods were used in parallel samplings in a suburban Algiers site and provided consistent results for semi-volatile congeners, as differences in the concentration data did not exceed 21% on average for individual carbonyl levels ranging from 0.0 to 0.5-2.6 microg m(-3). Concentrations of formaldehyde up to 27 and 5 microg m(-3) were monitored during 10 h samplings in the daytime in Algiers and Ouargla, respectively; acetaldehyde reached values of 13 and 5 microg m(-3), whilst acetone was the most abundant ketone with peak levels of 14 and 4 microg m(-3), respectively. High night-time levels of lower carbonyls were also measured at both locations. Among the semi-volatile alkanals, the highest levels were observed in suburban Algiers for hexanal and nonanal (2.2 microg m(-3)) and in downtown Algiers for valeraldehyde (2.6 microg m(-3)), whilst in Ouargla only hexanal and nonanal levels within the C5-C10 fraction exceeded 1 microg m(-3). Moreover, benzaldehyde concentrations as high as 5 microg m(-3) were measured in the centre of Algiers. Algiers data are comparable with those found in photochemically polluted urban areas of Europe and the USA. Strong correlations between formaldehyde and acetaldehyde and between formaldehyde and benzaldehyde were observed; by contrast, acetone did not show any correlation with the lower aldehydes, suggesting the existence of carbonyl sources other than vehicular traffic. Diurnal variations of almost all carbonyls suggested that motor vehicles were the most important source in the winter, whereas photochemical production appeared to predominate during the summer.  相似文献   
14.
15.
16.
The wintertime concentrations and diel cycles of n-alkanes and polycyclic aromatic hydrocarbons (PAHs) associated to atmospheric particulate matter with aerodynamic diameter lesser than 10 μm were determined at the biggest student residence in Algeria located in Bab-Ezzouar, 15 km southeast from Algiers city area. Samplings were carried out from December 2009 to March 2010, and organic compounds were characterized using gas chromatography coupled with mass spectrometric detection. Volatile PAHs were also monitored inside some student residence rooms in order to evaluate the impact of indoor air pollution to student health. For the sake of comparison, aerial concentrations of n-alkanes and PAHs were determined in parallel in the Oued Smar industrial zone and two suburban areas, all located in Algiers. Total concentrations recorded in CUB1 student residence ranged from 101 to 204 ng?m?3 for n-alkanes and from 8 to 87 ng?m?3 for PAHs. Diel cycles have shown that, while concentrations of n-alkanes peaked at morning and afternoon–evening and dropped at night, those of PAHs exhibited higher levels at morning and night and lower levels at afternoon–evening, likely due to the reactivity of some PAHs. As expected, the indoor levels of PAHs were larger than in the outdoor of the student residence and were of serious health concern. Overall, the concentrations of n-alkanes and PAHs were as high as those observed in the industrial zone and higher than the two suburban sites.  相似文献   
17.
Three natural clayey soils from Tunisia were studied to assess their suitability for use as a liner for an acid waste disposal site. An investigation of the effect of the mineral composition and mechanical compaction on the hydraulic conductivity and fluoride and phosphate removal of three different soils is presented. The hydraulic conductivity of these three natural soils are 8.5 × 10?10, 2.08 × 10?9 and 6.8 × 10?10 m/s for soil-1, soil-2 and soil-3, respectively. Soil specimens were compacted under various compaction strains in order to obtain three wet densities (1850, 1950 and 2050 kg/m3). In this condition, the hydraulic conductivity (k) was reduced with increasing density of sample for all soils. The test results of hydraulic conductivity at long-term (>200 days) using acidic waste solution (pH = 2.7, charged with fluoride and phosphate ions) shows a decrease in k with time only for natural soil-1 and soil-2. However, the specimens of soil-2 compressed to the two highest densities (1950 and 2050 kg/m3) are cracked after 60 and 20 days, respectively, of hydraulic conductivity testing. This damage is the result of a continued increase in the internal stress due to the swelling and to the effect of aggressive wastewater. The analysis of anions shows that the retention of fluoride is higher compared to phosphate and soil-1 has the highest sorption capacity.  相似文献   
18.
To understand acute toxicity and oxidative stress of perfluorinated compounds in the freshwater ecosystems, we exposed freshwater mussels (Unio ravoisieri) to perfluorooctane sulfonate (PFOS), over a range of concentrations from 10 to 100?mg/L, in a laboratory experiment. Lethal concentration (LC50) was of about 65.9?mg/L after 96?h of exposure. The oxidative stress was assessed in gill and digestive gland of the freshwater mussels after 7 days of exposure to different nominal PFOS concentrations (C1=?2?mg/L, C2?=?6?mg/L and C3=?10?mg/L). C1 and C2 increased significantly (p?<?.05) the superoxide dismutase activity in both tissues compared, while the highest C3 decreased the enzyme activity. This implements an unfavourable response that highlights the excess of reactive oxygen species produced after contamination. The Catalase activity was also increased by about 40.05% and 66.63%, respectively, in gill and digestive gland after exposure to C3. The Malondialdehyde (MDA) level was increased in both gill and digestive gland in a concentration-dependent pattern. In contrast, the contamination of U. ravoisieri by PFOS did not affect the acetylcholinesterase activity in both organs (p?>?.005). These results provided information on potential biomarkers that could be effectively applied for the monitoring of freshwater ecosystem using indicator species such as U. ravoisieri.  相似文献   
19.
The suitable design is the most important key to a cost-effective solar air heater. Although there are many techniques that have been proposed to improve the solar air heaters’ performance by means of different turbulence promoters, they cannot ensure a compromise between the cost and the effectiveness. The aim of this study is to find simple and tolerable solution to get rid of the inconvenience resulting from the widely adopted heat-transfer-enhancement techniques by providing an optimized solar air heater design. The proposed design consists of a slightly curved smooth flow channel with an absorber plate of convex shape. A prototype of a curved solar air heater of 1.28 m2 collector area was built and tested under summer outdoor conditions in Biskra (Algeria). The performance was evaluated in terms of thermal and effective efficiency for mass flow rates of 0.0172, 0.029, and 0.0472 kg/sm2. It is observed that the overall efficiency of this solar air heater is considerably higher in comparison with the efficiency range of the conventional smooth flat plate heaters reported in the literature for similar operating conditions.  相似文献   
20.
Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号