首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   24篇
  免费   3篇
安全科学   7篇
综合类   3篇
基础理论   8篇
污染及防治   6篇
评价与监测   3篇
  2020年   1篇
  2019年   2篇
  2018年   2篇
  2016年   1篇
  2014年   3篇
  2013年   4篇
  2012年   3篇
  2009年   2篇
  2008年   3篇
  2003年   1篇
  2001年   1篇
  2000年   1篇
  1989年   1篇
  1985年   1篇
  1977年   1篇
排序方式: 共有27条查询结果,搜索用时 15 毫秒
21.
ABSTRACT

Airborne measurements were made of gaseous and particulate species in the plume of a large coal-fired power plant after flue gas desulfurization (FGD) controls were installed. These measurements were compared with measurements made before the controls were installed. The light scattering and number and volume distributions of plume excess particles were determined by nephelometry and optical particle counting techniques. The plume impact based on optical techniques was much lower than that observed in earlier measurements. Indeed, plume excess volumes as a function of particle size were of the same magnitude as the variability of the background volume distribution. In situ excess plume scattering actually decreased with distance from the source, in contrast to pre-FGD conditions. The upper limit for the dry rate of SO2-to-SO4 2- conversion was estimated from plume excess volume measurements to be about 4% lir1. This is slightly greater than the upper limit, 3.5% lir1, estimated by earlier researchers, but the same as that estimated using the present technique with the earlier data. The cross-plume profile of volume suggests SO2-to-SO4 2- conversion is highest at the plume edges. The greatest benefit of SO2 reduction on plume excess volume and visibility appears to occur far downwind of the source.  相似文献   
22.
ABSTRACT

The rate of conversion of SO2 to SO4 2- was re-estimated from measurements made in the plume of the Cumberland power plant, located on the Cumberland River in north-central Tennessee, after installation of flue gas desulfurization (FGD) scrubbers for SO2 removal in 1994. The ratio of SO2 to NOy emissions into the plume has been reduced to ~0.1, compared with a prescrubber value of ~2. To determine whether the SO2 emissions reduction has correspondingly reduced plume-generated particulate SO4 2- production, we have compared the rates of conversion before and after scrubber installation. The prescrubber estimates were developed from measurements made during the Tennessee Plume Study conducted in the late 1970s. The post-scrubber estimates are based upon two series of research flights in the summers of 1998 and 1999. During two of these flights, the Cumberland plume did not mix with adjacent power plant plumes, enabling rate constants for conversion to be estimated from samples taken in the plume at three downwind distances. Dry deposition losses and the fact the fact that SO2 is no longer in large excess compared with SO4 2- have been taken into account, and an upper limit for the conversion rate constant was re-estimated based on plume excess aerosol volume. The estimated upper limit values are 0.069 hr-1 and 0.034 hr-1 for the 1998 and 1999 data, respectively. The 1999 rate is comparable with earlier values for nonscrubbed plumes, and although the 1998 upper limit value is higher than expected, these estimates do not provide strong evidence for deviation from a linear relationship between SO2 emissions and SO4 2- formation.  相似文献   
23.
Systematic reviews are an increasingly popular decision‐making tool that provides an unbiased summary of evidence to support conservation action. These reviews bridge the gap between researchers and managers by presenting a comprehensive overview of all studies relating to a particular topic and identify specifically where and under which conditions an effect is present. However, several technical challenges can severely hinder the feasibility and applicability of systematic reviews, for example, homonyms (terms that share spelling but differ in meaning). Homonyms add noise to search results and cannot be easily identified or removed. We developed a semiautomated approach that can aid in the classification of homonyms among narratives. We used a combination of automated content analysis and artificial neural networks to quickly and accurately sift through large corpora of academic texts and classify them to distinct topics. As an example, we explored the use of the word reintroduction in academic texts. Reintroduction is used within the conservation context to indicate the release of organisms to their former native habitat; however, a Web of Science search for this word returned thousands of publications in which the term has other meanings and contexts. Using our method, we automatically classified a sample of 3000 of these publications with over 99% accuracy, relative to a manual classification. Our approach can be used easily with other homonyms and can greatly facilitate systematic reviews or similar work in which homonyms hinder the harnessing of large text corpora. Beyond homonyms we see great promise in combining automated content analysis and machine‐learning methods to handle and screen big data for relevant information in conservation science.  相似文献   
24.
25.
Airborne measurements were made of gaseous and particulate species in the plume of a large coal-fired power plant after flue gas desulfurization (FGD) controls were installed. These measurements were compared with measurements made before the controls were installed. The light scattering and number and volume distributions of plume excess particles were determined by nephelometry and optical particle counting techniques. The plume impact based on optical techniques was much lower than that observed in earlier measurements. Indeed, plume excess volumes as a function of particle size were of the same magnitude as the variability of the background volume distribution. In situ excess plume scattering actually decreased with distance from the source, in contrast to pre-FGD conditions. The upper limit for the dry rate of SO2-to-SO4(2-) conversion was estimated from plume excess volume measurements to be about 4% hr-1. This is slightly greater than the upper limit, 3.5% hr-1, estimated by earlier researchers, but the same as that estimated using the present technique with the earlier data. The cross-plume profile of volume suggests SO2-to-SO4(2-) conversion is highest at the plume edges. The greatest benefit of SO2 reduction on plume excess volume and visibility appears to occur far down-wind of the source.  相似文献   
26.
Samples of Jerusalem limestones were exposed to high levels of common air pollutants (SO2, NO) in the presence and absence of hydrocarbon, water vapor and ultra-violet light. After exposure, the outer layers were shaved off and analyzed for sulfate and nitrate. The results revealed that even after one day of exposure significant concentrations of CaSO4 and Ca(NO3)2 could be detected in the external 40 m layers. Sulfate formation was found to relate very strongly to relative humidity with nearly undetectable production at humidities below 10%. Nitrate formation was found to relate to UV light and to a limited extent to the presence of hydrocarbon but was unchanged at different humidities. Surface samples were taken from different sites of the old city wall and were also analyzed for the same substances. The data showed that the concentrations of especially CaSO4, and to a limited extend Ca(NO3)2, measured at various points along the city walls were higher than the expected values extrapolated from laboratory simulations. The elevated pollution content may be explained in part due to the deposition of transported ions, especially sulfate, onto the stone surface. It was concluded that although air pollution may not cause any structural damage in the foreseeable future it definitely deteriorates the fine details of the ancient monument.  相似文献   
27.
The rate of conversion of SO2 to SO4(2-) was re-estimated from measurements made in the plume of the Cumberland power plant, located on the Cumberland River in north-central Tennessee, after installation of flue gas desulfurization (FGD) scrubbers for SO2 removal in 1994. The ratio of SO2 to NOy emissions into the plume has been reduced to approximately 0.1, compared with a prescrubber value of approximately 2. To determine whether the SO2 emissions reduction has correspondingly reduced plume-generated particulate SO4(2-) production, we have compared the rates of conversion before and after scrubber installation. The prescrubber estimates were developed from measurements made during the Tennessee Plume Study conducted in the late 1970s. The postscrubber estimates are based upon two series of research flights in the summers of 1998 and 1999. During two of these flights, the Cumberland plume did not mix with adjacent power plant plumes, enabling rate constants for conversion to be estimated from samples taken in the plume at three downwind distances. Dry deposition losses and the fact the fact that SO2 is no longer in large excess compared with SO4(2-) have been taken into account, and an upper limit for the conversion rate constant was re-estimated based on plume excess aerosol volume. The estimated upper limit values are 0.069 hr(-1) and 0.034 hr(-1) for the 1998 and 1999 data, respectively. The 1999 rate is comparable with earlier values for nonscrubbed plumes, and although the 1998 upper limit value is higher than expected, these estimates do not provide strong evidence for deviation from a linear relationship between SO2 emissions and SO4(2-) formation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号