首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   45篇
  免费   3篇
废物处理   3篇
环保管理   3篇
综合类   5篇
基础理论   17篇
污染及防治   18篇
评价与监测   2篇
  2021年   4篇
  2020年   1篇
  2018年   2篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2014年   1篇
  2013年   6篇
  2012年   3篇
  2011年   1篇
  2010年   1篇
  2009年   3篇
  2007年   3篇
  2006年   1篇
  2005年   2篇
  2003年   1篇
  2002年   2篇
  2001年   1篇
  2000年   3篇
  1995年   3篇
  1994年   2篇
  1991年   1篇
  1987年   1篇
  1984年   1篇
  1983年   1篇
  1982年   1篇
排序方式: 共有48条查询结果,搜索用时 46 毫秒
31.
Hot water recirculation systems (HWRS) in hotels and nursing homes, which are common in countries such as Spain, have been related to outbreaks of legionellosis. To establish the relationships of microbial and physicochemical parameters, especially protozoa, with the occurrence of Legionella in HWRS, 231 samples from hotels and nursing homes were analysed for Legionella, protozoa, heterotrophic plate counts (HPC) at 22 and 37 °C, Pseudomonas, metals, temperature and others. Legionella pneumophila was the dominant species isolated, and 22 % were sg. 1. The sampling method became particularly important in order to define which factors were involved on the occurrence of Legionella. Results showed that the bacteria and the accompanying microbiota were more abundant in the first flush water whose temperature was lower. The bacteria occurred in those samples with high HPC and were inversely correlated with high temperatures. Multivariate regression showed that a concentration above 1?×?105?CFU/100 mL of HPC at 37 °C, Fe above 0.095 ppm and the presence of protozoa increased significantly the risk of Legionella colonization, while univariant regression showed that the presence of Cu above 0.76 ppm and temperature above 55 °C diminished it. Therefore, to reduce the risk associated with Legionella occurrence in HWRS these parameters should be taken into consideration.  相似文献   
32.
Abstract

Sources and concentrations of indoor nitrogen dioxide (NO2) were examined in Barcelona, Spain, during 1996– 1999. A total of 340 dwellings of infants participating in a hospital-based cohort study were selected from different areas of the city. Passive filter badges were used for indoor NO2 measurement over 7–30 days. Dwelling inhabitants completed a questionnaire on housing characteristics and smoking habits. Data on outdoor NO2 concentrations were available for the entire period of the study in the areas of the city where indoor concentrations were determined. Bivariate analysis was performed to investigate relationships between indoor NO2 concentrations on one hand and outdoor NO2 concentrations, housing, and occupant characteristics on the other. Stepwise multiple linear regression was performed with variables that were 1996 and 27.02 ppb in 1999, with the highest yearly value of 27.82 ppb in 1997. In the same time period, mean outdoor NO2 concentration ranged between 25.26 and 25.78 ppb with a peak of 30.5 ppb in 1998. Multiple regression analysis showed that principal sources of indoor NO2 concentrations were the use of a gas cooker, the absence of an extractor fan when cooking, and cigarette smoking. The absence of central heating was also associated with higher NO2 concentrations. Finally, each ppb increase in outdoor NO2 was associated with a 1% increase in indoor concentrations.  相似文献   
33.
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H2S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods of at least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H2S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0 ± 1.8%, seems not to depend on the amount of H2S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H2S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H2S emissions are dominant.

Implications: Passive samplers are very attractive tools to experimentally tackle a number of air pollution problems, especially those related to odor impact. Their small size and cost permit a denser sampling design and thus a more detailed spatial characterization than other techniques. On the other hand, the large inherent variability in passive sampler measures requires an uncertainty analysis of the chemical species and analytical procedures used.  相似文献   
34.
A full-scale field study was carried out at two Spanish coal-fired power plants equipped with electrostatic precipitator (ESP) and wet flue gas desulfurisation (FGD) systems to investigate the distribution of boron in coals, solid by-products, wastewater streams and flue gases. The results were obtained from the simultaneous sampling of solid, liquid and gaseous streams and their subsequent analysis in two different laboratories for purposes of comparison. Although the final aim of this study was to evaluate the partitioning of boron in a (co-)combustion power plant, special attention was paid to the analytical procedure for boron determination. A sample preparation procedure was optimised for coal and combustion by-products to overcome some specific shortcomings of the currently used acid digestion methods. In addition boron mass balances and removal efficiencies in ESP and FGD devices were calculated. Mass balance closures between 83 and 149% were obtained. During coal combustion, 95% of the incoming boron was collected in the fly ashes. The use of petroleum coke as co-combustible produced a decrease in the removal efficiency of the ESP (87%). Nevertheless, more than 90% of the remaining gaseous boron was eliminated via the FGD in the wastewater discharged from the scrubber, thereby causing environmental problems.  相似文献   
35.
36.
An interaction between the alcyonarian octocoral Nephthea brassica Kukenthal, 1904 and the scleractinian Acropora hyacinthus Dana was photographed and the assemblage collected at Rib Reef (18°15S; 146°45E), Central Region of the Great Barrier Reef, in September 1980. The interaction, which did not involve allelopathy, was characterised by extensive deposition of undifferentiated aragonite by the scleractinian in the vicinity of the soft coral, which moved across the surface of the acroporid. The basal attachment region of the nephtheid showed structural features which permitted movement. The net effect of this interaction was a series of divided trails across the surface of the acroporid plate evidencing the movement through growth and asexual division of the parent colony. These trails were susceptible to secondary colonisation by epifauna and algae which may reduce the fitness of the acroporid. This movement appears to afford N. brassica a distinct advantage in competing for space with acroporid corals.  相似文献   
37.
The analysis of planar (non-ortho) polychlorinated biphenyls (PCB) by HRGC-ECD or HRGC-HRMS requires a fractionation step to avoid the interferences of the bulk of PCB, usually in much higher concentration than the planar ones. In this paper, a new method, based on the fractionation of PCB on SPE commercial tubes pre-packed with Carbopack B, has been developed. After the extract has been applied on the stationary phase, the bulk of PCD are eluted with 15 ml of hexane (fraction I), mono-ortho PCB with 20 ml of hexane/toluene 99:1 (fraction II) and planar PCB with 20 ml of toluene (fraction III) in a station under vacuum. The method has been validated: accuracy (expressed as recovery in %) is >70% and precision (expressed as % RSD) is <20% considering changes of day, analyst and batch of tubes. The method is linear in the range studied. Other advantages are that the method is simple, rapid and it can be easily automated. The application of this separation to the determination of planar PCB in fly-ash extracts from an intercalibration exercise and to sewage sludge, sediment and soil samples has been successful. In addition, this method removes hydrocarbons from the planar PCB fraction and allows its concentration to very small volumes.  相似文献   
38.
The evolution of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in sewage sludge-amended soils used in the restoration of degraded lands, like quarries, has been studied. Two experiments were performed: one in the lab, under controlled conditions, and another in a quarry. Two different doses of sewage sludge were applied in both experiments (with two types of application in the quarry experiment) and the evolution of the amended soils were compared with that of the respective control soils (without addition of sewage sludge). The samples were analyzed with a previously validated method by HRGC HRMS after the extraction and the necessary clean-up steps. The results reveal that polluted sewage sludge increases PCDD/F concentration in soils and that these compounds are persistent in the matrix after long periods of time.  相似文献   
39.
Colonies of the soft coral Lobophytum pauciflorum (Ehrenberg, 1834) (Coelenterata: Octocorallia: Alcyonacea: Alcyoniidae), some of which were heavily overgrown by the algae Ceranium flaccidum (Kuetzing) Ardissone and Enteromorpha sp., and other minor epizoites, were collected at Taylor Reef (17°50S; 146°35E) in the Great Barrier Reef. Overgrown colonies contained the diterpene 2-epi-sarcophytoxide as the major secondary metabolite, while conspecific colonies with clean polyparies contained two diterpenes in approximately equal amounts: 14-hydroxycembra-1,3,7,11-tetraene and 15-hydroxycembra-1,3,7,11-tetraene. By contrast, twenty conspecific pairs of overgrown and clean colonies of other alcyoniid soft corals collected from Pelorus Channel, Palm Island Group (18°34S; 146°29E), showed no chemical differences within in the pairs. Cultures of a common species of Ceramium [C. codii (Richards) Mazoyer] were incubated with different concentrations of nine soft-coral-derived diterpenes and significant algal growth inhibition was observed in many cases. It appears that terpenoids from soft coral may contribute to the lack of epizoic organisms on soft-coral polyparies.  相似文献   
40.
Replacement of peat as a growing medium by a renewable material, such as an organic waste, is an issue of concern since harvesting of peat has a considerable environmental impact and, actually, it is a non-renewable resource. Cattle manure is a readily available organic waste, which means that once it goes through the composting process, it can be used as an alternative to peat, specifically, the solid fraction obtained from mechanical liquid-solid separation of cattle slurry (SF). Studies have shown it to be suitable for such uses. The purpose of this study was to detect possible changes in the physicochemical and chemical properties of SF when it is composted using different aeration strategies, with an emphasis on the changes that would make it feasible for use as a substrate. With this aim in mind, an experiment was designed with three aeration strategies that would be used during composting. The first consisted of applying air through a static method (forced ventilation). The second involved improving aeration by adding a bulking agent and a dynamic turning method. In the third strategy, aeration was carried out by turning (control). The results show that the different aeration strategies had a clear effect on the evolution of pH, electrical conductivity (EC), nitrate-N, ammonia-N and bicarbonate content. Nitrification was favored under good aeration conditions using the static composting method, probably due to the greater availability of ammonia-N that was transformed into nitrate-N. In general, the low buffering capacity allowed for a reduction of the pH during the curing stage of composting (in conjunction with low temperatures during this period), a characteristic that favors the use of this compost as a growing medium. We also conclude that measuring bicarbonate levels during composting could be used as an indicator of the possible acidification of the material and as a way of evaluating the level of material aeration.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号