An indicator of the disturbance of natural systems, the landscape development intensity (LDI) index, was used to assess the potential for land-use within watersheds to influence the production/accumulation of methyl-mercury (MeHg) in river sediments. Sediment samples were collected from locations impacted by well-identified land-use types within the Mobile-Alabama River Basin in Southeastern USA. The samples were analyzed for total-Hg (THg) and MeHg concentrations and the obtained values correlated to the calculated LDI indexes of the sampled watersheds to assess the impact of prevalent land use/land cover on MeHg accumulation in sediments. The results show that unlike THg, levels of MeHg found in sediments are impacted by the LDI indexes. Overall, certain combinations of land-use types within a given watershed appear to be more conducive to MeHg accumulation than others, therefore, pointing to the possibility of targeting land-use practices as potential means for reducing MeHg accumulation in sediments, and ultimately, fish contamination. 相似文献
The present study aimed to improve the performance of microbial fuel cells (MFCs) by using an intermittent connection period without power output. Connecting two MFCs in parallel improved the voltage output of both MFCs until the voltage stabilized. Electric energy was accumulated in two MFCs containing heavy metal ions copper, zinc, and cadmium as electron acceptors by connection in parallel for several hours. The system was then switched to discharge mode with single MFCs with a 1000-Ω resistor connected between anode and cathode. This method successfully achieved highly efficient removal of heavy metal ions. Even when the anolyte was run in sequencing batch mode, the insufficient voltage and power needed to recover heavy metals from the cathode of MFCs can be complemented by the developed method. The average removal ratio of heavy metal ions in sequencing batch mode was 67 % after 10 h. When the discharge time was 20 h, the removal ratios of zinc, copper, and cadmium were 91.5, 86.7, and 83.57 %, respectively; the average removal ratio of these ions after 20 h was only 52.1 % for the control group. Therefore, the average removal efficiency of heavy metal ions increased by 1.75 times using the electrons stored from the bacteria under the open-circuit conditions in parallel mode. Electrochemical impedance data showed that the anode had lower solution resistance and polarization resistance in the parallel stage than as a single MFC, and capacitance increased with the length of time in parallel.
Biological aerated filters (BAFs) are widely used for the treatment of micropolluted surface water. However, the biological process produces dissolved organic nitrogen (DON), which, as precursors of nitrogenous disinfection by-products, pose potential threats to drinking water safety. Therefore, to control DON in BAF effluent, it is necessary to study the influence of BAF operation parameters on DON production. In this study, the influence of filtration velocity in a BAF on DON production was investigated. Under different filtration velocity (0.5, 2, and 4 m/h) conditions, profiles of DON concentrations along the media layer were measured. The profile at a filtration velocity of 0.5 m/h showed a decreasing trend, and the ones under filtration velocities of 2 and 4 m/h fluctuated in a small range (from 0.1 to 0.4 mg/L). Moreover, the relatively high filtration velocities of 2 and 4 m/h resulted in a lower level of DON concentration. Additionally, 3D excitation-emission matrix fluorescence spectroscopy was used to characterize DON. It is found that the patterns of DON at a relatively high filtration velocity condition (4 m/h) were obviously different from the ones under low filtration velocity conditions (0.5 and 2 m/h). 相似文献
Knowledge on atmospheric abundance of peroxyacetyl nitrate (PAN) is important in assessing the severity of photochemical pollution, and for understanding chemical transformation of reactive odd nitrogen and its impact on the budget of tropospheric ozone (O3). In summer 2006, continuous measurements of PAN were made using an automatic GC–ECD analyzer with an on-line calibrator at a suburban site of Lanzhou (LZ) and a remote site of Mt. Waliguan (WLG) in western China, with concurrent measurements of O3, total reactive nitrogen (NOy) and carbon monoxide (CO). At LZ, several photochemical episodes were observed during the study, and the average mixing ratio of PAN (plus or minus standard deviation) was 0.76 (±0.89) ppbv with the maximum value of 9.13 ppbv, compared to an average value of 0.44 (±0.16) ppbv at remote WLG. The PAN mixing ratios in LZ exhibited strong diurnal variations with a maximum at noon, while enhanced concentrations of PAN were observed in the evening and a minimum in the afternoon at WLG. The daily O3 and PAN concentration maxima showed a strong correlation (r2 = 0.91) in LZ, with a regression slope (PAN/O3) of 0.091 ppbv ppbv?1. At WLG, six well-identified pollution plumes (lasting 2–8 h) were observed with elevated concentrations of PAN (and other trace gases), and analysis of backward particle release simulation shows that the high-PAN events at WLG were mostly associated with the transport of air masses that had passed over LZ. 相似文献