全文获取类型
收费全文 | 161篇 |
免费 | 1篇 |
国内免费 | 8篇 |
专业分类
安全科学 | 12篇 |
废物处理 | 19篇 |
环保管理 | 8篇 |
综合类 | 18篇 |
基础理论 | 21篇 |
污染及防治 | 72篇 |
评价与监测 | 18篇 |
社会与环境 | 2篇 |
出版年
2022年 | 5篇 |
2021年 | 6篇 |
2019年 | 4篇 |
2018年 | 6篇 |
2017年 | 10篇 |
2016年 | 5篇 |
2015年 | 1篇 |
2014年 | 9篇 |
2013年 | 17篇 |
2012年 | 14篇 |
2011年 | 16篇 |
2010年 | 10篇 |
2009年 | 10篇 |
2008年 | 9篇 |
2007年 | 10篇 |
2006年 | 6篇 |
2005年 | 2篇 |
2004年 | 7篇 |
2003年 | 5篇 |
2002年 | 6篇 |
2001年 | 7篇 |
1999年 | 1篇 |
1998年 | 1篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1991年 | 1篇 |
排序方式: 共有170条查询结果,搜索用时 15 毫秒
21.
Assessment of fates of estrogens in wastewater and sludge from various types of wastewater treatment plants 总被引:1,自引:0,他引:1
We measured five estrogens in the wastewater samples from the municipal wastewater treatment plants (M-WWTPs), livestock wastewater treatment plants (L-WWTPs), hospital WWTPs (H-WWTPs) and pharmaceutical manufacture WWTPs (P-WWTPs) in Korea. The L-WWTPs showed the highest total concentration (0.195-10.4 μg L−1) of estrogens in the influents, followed by the M-WWTPs (0.028-1.15 μg L−1), H-WWTPs (0.068-0.130 μg L−1) and P-WWTPs (0.015-0.070 μg L−1). Like the influents, the L-WWTPs (0.003-0.729 μg L−1) and the M-WWTPs (0.001-0.299 μg L−1) also showed higher total concentration of estrogens in the effluents than the H-WWTPs (0.002-0.021 μg L−1) and P-WWTPs (0.011 μg L−1 in one sample). The L-WWTPs (37.5-543 μg kg−1, dry weight) showed higher total concentrations in sludge than the M-WWTPs (3.16-444 μg kg−1, dry weight) like the wastewater. The distribution of estrogens in the WWTPs may be affected by their metabolism in the human body, their transition through biological treatment processes, and their usage for livestock growth. Unlike the concentration results, the daily loads of estrogens from the M-WWTPs were the highest, which is related to the high capacities of WWTPs. 相似文献
22.
Beverly Z.L. Oh Ana M.M. Sequeira Mark G. Meekan Jonathan L.W. Ruppert Jessica J. Meeuwig 《Conservation biology》2017,31(3):635-645
Fishing and habitat degradation have increased the extinction risk of sharks, and conservation strategies recognize that survival of juveniles is critical for the effective management of shark populations. Despite the rapid expansion of marine protected areas (MPAs) globally, the paucity of shark‐monitoring data on large scales (100s–1000s km) means that the effectiveness of MPAs in halting shark declines remains unclear. Using data collected by baited remote underwater video systems (BRUVS) in northwestern Australia, we developed generalized linear models to elucidate the ecological drivers of habitat suitability for juvenile sharks. We assessed occurrence patterns at the order and species levels. We included all juvenile sharks sampled and the 3 most abundant species sampled separately (grey reef [Carcharhinus amblyrhynchos], sandbar [Carcharhinus plumbeus], and whitetip reef sharks [Triaenodon obesus]). We predicted the occurrence of juvenile sharks across 490,515 km2 of coastal waters and quantified the representation of highly suitable habitats within MPAs. Our species‐level models had higher accuracy (? ≥ 0.69) and deviance explained (≥48%) than our order‐level model (? = 0.36 and deviance explained of 10%). Maps of predicted occurrence revealed different species‐specific patterns of highly suitable habitat. These differences likely reflect different physiological or resource requirements between individual species and validate concerns over the utility of conservation targets based on aggregate species groups as opposed to a species‐focused approach. Highly suitable habitats were poorly represented in MPAs with the most restrictions on extractive activities. This spatial mismatch possibly indicates a lack of explicit conservation targets and information on species distribution during the planning process. Non‐extractive BRUVS provided a useful platform for building the suitability models across large scales to assist conservation planning across multiple maritime jurisdictions, and our approach provides a simple for method for testing the effectiveness of MPAs. 相似文献
23.
Oh CJ Lee SO Yang HS Ha TJ Kim MJ 《Journal of the Air & Waste Management Association (1995)》2003,53(7):897-902
This study was carried out to recover valuable metals from the printed circuit boards (PCBs) of waste computers. PCB samples were crushed to smaller than 1 mm by a shredder and initially separated into 30% conducting and 70% nonconducting materials by an electrostatic separator. The conducting materials, which contained the valuable metals, were then used as the feed material for magnetic separation, where it was found that 42% of the conducting materials were magnetic and 58% were nonmagnetic. Leaching of the nonmagnetic component using 2 M H2SO4 and 0.2 M H2O2 at 85 degrees C for 12 hr resulted in greater than 95% extraction of Cu, Fe, Zn, Ni, and Al. Au and Ag were extracted at 40 degrees C with a leaching solution of 0.2 M (NH4)2S2O3, 0.02 M CuSO4, and 0.4 M NH4OH, which resulted in recovery of more than 95% of the Au within 48 hr and 100% of the Ag within 24 hr. The residues were next reacted with a 2 M NaCl solution to leach out Pb, which took place within 2 hr at room temperature. 相似文献
24.
25.
26.
Sang-Sup Lee Seong-Man Mun Won-Joon Choi Byoung-Moo Min Sang-Won Cho Kwang-Joong Oh 《环境科学学报(英文版)》2012,24(5):897-902
Aqueous 1,8-diamino-p-menthane (KIER-C3) and commercially available amine solutions were tested for CO2 absorption. A 2-amino- 2-methyl-1-propanol (AMP) solution with an addition of KIER-C3 showed 9.3% and 31.6% higher absorption rate for CO2 than the AMP solution with an addition of monoethanolamine (MEA) and ammonia (NH3), respectively. The reaction rate constant for CO2 absorption by the AMP/KIER-C3 solution was determined by the following equation: k2,AMP/C3 = 7.702×106 exp (-2248.03/T). A CO2 loading ratio of the AMP/KIER-C3 solution was also 2 and 3.4-times higher than that of the AMP/NH3 solution and the AMP/MEA solution, respectively. Based on the experimental results, KIER-C3 may be used as an excellent additive to increase CO2 absorption capability of AMP. 相似文献
27.
Nationwide monitoring of polychlorinated biphenyls and organochlorine pesticides in sediments from coastal environment of Korea 总被引:1,自引:0,他引:1
To assess the organochlorine contamination in the Korean marine environment, a nationwide monitoring study was conducted. A total of 138 surface sediments, covering the whole Korean coast, were collected and analyzed. Organochlorine compounds (OCs) were widely distributed in the Korean coastal environment, with PCB and DDT contamination being particularly prevalent. The overall concentrations of PCBs, DDTs, HCHs, CHLs, and HCB in surface sediments were in the range of 0.088-199ngg(-1) (median value: 1.56ngg(-1)), 0.006-135ngg(-1) (0.68ngg(-1)), not detected (ND)-5.46ngg(-1) (0.32ngg(-1)), ND-3.26ngg(-1) (0.14ngg(-1)), and ND-2.59ngg(-1) (0.05ngg(-1)), respectively. The southeastern coast was found to be highly contaminated. Overall contamination status of Korean coastal sediments with regard to OCs is lower than that of USA. With the exception of highly industrialized sites, Korean coastal areas in general showed similar OC concentrations to those of other Asian countries. There was a significant correlation between distributions of most organochlorine contaminants with each other. OC contamination is closely related to shipping and industrial activities. Of the 7 sites categorized as highly polluted, 4 are in a harbor zone. Adverse effects to benthic communities are expected at the levels of OC contamination observed from harbor and industrial areas. 相似文献
28.
I-Risk: development of an integrated technical and management risk methodology for chemical installations 总被引:1,自引:0,他引:1
I. A. Papazoglou L. J. Bellamy A. R. Hale O. N. Aneziris B. J. M. Ale J. G. Post J. I. H. Oh 《Journal of Loss Prevention in the Process Industries》2003,16(6):575-591
This paper presents an integrated quantitative risk assessment method for hazardous installations, taking into account management as well as technical design and producing risk level measures. The key components of the I-Risk methodology are the technical model, the management model and their interface. The technical model consists of developing a master logic diagram (MLD) delineating the major immediate causes of loss of containment (LOC) and associated quantitative models for assessing their frequency. The management model consists of the tasks, which must be carried out systematically in the primary business functions (such as operations, emergency operations, maintenance and modifications). A management audit quantifies the quality of these management tasks. The management–technical interface modifies certain parameters of the technical model on the basis of the quality of the safety management system of the specific installation. The methodology is exemplified through its application to the risk assessment of an ammonia storage facility. A detailed technical model simulating the response of the system to various initiating events is developed along with a detailed management model simulating the influence of the plant-specific management and organisational practices. The overall effect is quantified through the frequency of release of ammonia as a result of a loss of containment in a storage tank and in a pipeline. 相似文献
29.
Biodegradability of secondary amines (pyrrolidine, piperidine, piperazine, morpholine, and thiomorpholine) under anaerobic conditions was examined in microbial consortia from six different environmental sites. The consortia degraded pyrrolidine and piperidine under denitrifying conditions. Enrichment cultures were established by repeatedly sub-culturing the consortia on pyrrolidine or piperidine in the presence of nitrate. The enrichments strictly required nitrate for the anaerobic degradation and utilized pyrrolidine or piperidine as a carbon, nitrogen, and energy source for their anaerobic growths. The anaerobic degradation of pyrrolidine and piperidine reduced nitrate to nitrogen gas, indicating that these anaerobic degradations were coupled with a respiratory nitrate reduction. 相似文献
30.
A model for predicting the distribution of dibenzofuran and polychlorinated dibenzofuran (PCDF) congeners from a distribution of phenols was developed. The model is based on a simplified chemical mechanism. Relative rate constants and reaction order with respect to phenol precursors were derived from experimental results using single phenols and equal molar mixtures of up to four phenols. For validation, experiments were performed at three temperatures using a distribution of phenol and 19 chlorinated phenols as measured in municipal waste incinerator exhaust gas. Comparison of experimental measurements and model predictions for PCDF isomer distributions and homologue pattern shows agreement within measurement uncertainty. The R-squared correlation coefficient exceeds 0.9 for all PCDF isomer distributions and the distribution of PCDF homologues. These results demonstrate that the distribution of dibenzofuran and the 135 PCDF congeners from gas-phase condensation of phenol and chlorinated phenols can be predicted from measurement of the distribution of phenol and the 19 chlorinated phenol congeners. 相似文献