This paper presents detailed data on the thermal response of two 500 gal ASME code propane tanks that were 25% engulfed in a hydrocarbon fire. These tests were done as part of an overall test programme to study thermal protection systems for propane-filled railway tank-cars.
The fire was generated using an array of 25 liquid propane-fuelled burners. This provided a luminous fire that engulfed 25% of the tank surface on one side. The intent of these tests was to model a severe partially engulfing fire situation.
The paper presents data on the tank wall and lading temperatures and tank internal pressure. In the first test the wind reduced the fire heating and resulted in a late failure of the tank at 46 min. This tank failed catastrophically with a powerful boiling liquid expanding vapour explosion (BLEVE). In the other test, the fire heating was very severe and steady and this tank failed very quickly in 8 min as a finite rupture with massive two-phase jet release. The reasons for these different outcomes are discussed. The different failures provide a range of realistic outcomes for the subject tank and fire condition. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献
Ammonia emissions from two contrasting seabird colonies in Scotland were measured, based on the determination of atmospheric concentrations downwind of the colonies. Atmospheric concentrations of ammonia (NH3) across the downwind plume were compared with the inverse application of a Gaussian dispersion model (ID) to calculate the modelled NH3 emission that would generate the measured cross-wind-integrated plume concentration. In parallel, a tracer gas (sulphur hexafluoride, SF6) was released from the colonies with air samples taken to allow determination of SF6 concentrations. On the basis of the known emission rate of SF6, the magnitude of ammonia emissions was estimated by the cross-wind-integrated tracer ratio (TR) of NH3/SF6 concentrations. Coupled with data on annual bird attendance, the measurements indicate annual emissions from the Isle of May and the Bass Rock of 18 and 132 tonnes NH3-N year–1, respectively. The measured NH3 emissions were compared with estimates of seabird nitrogen excretion to estimate the proportion of excreted N that is volatilised as NH3 (FNr). The emission estimates of the two methods compared favourably, giving 4 and 6 kg NH3-N h–1 (FNr = 15%) for the Isle of May for the ID and TR methods, respectively, and 21 and 25 kg NH3-N h–1 (FNr = 50%) for the Bass Rock for the ID and TR methods, respectively. The results provide the first measurement-based estimates to allow regional up scaling of ammonia emissions from seabirds. 相似文献
The distribution and impacts of different nitrogen pollutants are inextricably linked. To understand the problem fully, the interactions between the different pollutants need to be taken into account. This is particularly important when it comes to abatement techniques, since measures to reduce emissions of one nitrogen pollutant can often lead to an increase in another. This project represents a step towards greater understanding of these issues by linking together new and existing nitrogen flux models into a larger framework. The modelling framework has been constructed and some of the nitrogen flows between fields, farms and the atmosphere have been modelled for a UK study area for typical farm management scenarios. 相似文献
The potential for metabolic fingerprinting via Fourier-transform infrared (FT-IR) spectroscopy to provide a novel approach for the detection of plant biochemical responses to N deposition is examined. An example of spectral analysis using shoot samples taken from an open top chamber (OTC) experiment simulating wet ammonium deposition is given. Sample preparation involved oven drying and homogenisation via mill grinding. Slurries of a consistent dilution were then prepared prior to FT-IR analysis. Spectra from control, 8 and 16 kg N ha–1 yr–1 treatments were then subjected to cross-validated discriminant function analysis. Ordination diagrams showed clear separation between the three N treatments examined. The potential for using Calluna vulgaris (L.) Hull as a bioindicator of N deposition is further evident from these results. The results also clearly demonstrate the power of FT-IR in discriminating between subtle phenotypic alterations in overall plant biochemistry as affected by ammonium pollution. 相似文献
Water, Air, &; Soil Pollution: Focus - What should System Managers prefer? Systems that never fail or systems that remain safe during a failure? The present paper tries to give an answer to this... 相似文献
In this investigation, all the techniques used in the chemical recycling of polyethylene terephthalate (PET) are critically reviewed according to the overall benefits together with the environmental surcharge that they cause. Those, which are consistent with the principles of sustainable development, are indicated. Experimental data are presented for the acid hydrolysis of PET and compared with previous results on the alkaline hydrolysis of PET with, or without, the use of a phase transfer catalyst. Overall material balances are carried out for the hydrolysis of PET. Finally, it can be postulated that recycling according to the scheme: is the only one within the framework of sustainable development. Therefore, the recycling of PET does not only serve as a partial solution to the solid waste problem but also contributes to the conservation of raw petrochemical products and energy. 相似文献