This first nationwide survey was conducted to evaluate the overall performance of the circulating fluidized bed (CFB) incineration of municipal solid waste (MSW) in 2014-2015 in China. Total 23 CFB incineration power plants were evaluated. The data for monthly average flue gas emission of particles, CO, NOx, SO2 and HCl were collected over 12 consecutive months. The data were analyzed to assess the overall performance of CFB incineration by applying the Mahalanobis distance as a multivariate outlier detection method. Although the flue gas emission parameters had met the Chinese national emission standards, there were 11 total outliers (abnormal behavior) detected in 6 out of 23 CFB incineration power plants from the perspective of the MSWincineration performance. The results demonstrate that it is more important for a better performance of CFBs to reduce the frequencies of the MSW load changes, rather than the magnitudes of the MSW load changes, particularly reducing the frequencies in the range of 10% and more of the load changes, under the same and stable conditions. Furthermore, the overloading occurs more often than the underloading during the operation of the CFB incineration power plants in China. The frequent overloading is 0% to 30% of the designed capacity. To achieve the stable performance of CFBs in practice, an appropriately designed MSW storage capacity is suggested to build in a plant to buffer and reduce the frequency of the load changes. 相似文献
Heavy metal-contaminated sediments posed a serious threat to both human beings and environment. A biosurfactant, rhamnolipid, was employed as the washing agent to remove heavy metals in river sediment. Batch experiments were conducted to test the removal capability. The effects of rhamnolipid concentration, washing time, solution pH, and liquid/solid ratio were investigated. The speciation of heavy metals before and after washing in sediment was also analyzed. Heavy metal washing was favored at high concentration, long washing time, and high pH. In addition, the efficiency of washing was closely related to the original speciation of heavy metals in sediment. Rhamnolipid mainly targeted metals in exchangeable, carbonate-bound or Fe-Mn oxide-bound fractions. Overall, rhamnolipid biosurfactant as a washing agent could effectively remove heavy metals from sediment.
Environmental Science and Pollution Research - Phytoremediation coupled with crop rotation (PCC) is a feasible strategy for remediation of contaminated soil without interrupting crop production.... 相似文献
Environmental Science and Pollution Research - Sediment samples were collected in five marshes (C1, Phragmites australis marsh; C2, P. australis and Cyperus malaccensis marsh; C3, C. malaccensis... 相似文献
Vehicle-specific power (VSP) has been found to be highly correlated with vehicle emissions. It is used in many studies on emission modeling such as the MOVES (Motor Vehicle Emissions Simulator) model. The existing studies develop specific VSP distributions (or OpMode distribution in MOVES) for different road types and various average speeds to represent the vehicle operating modes on road. However, it is still not clear if the facility- and speed-specific VSP distributions are consistent temporally and spatially. For instance, is it necessary to update periodically the database of the VSP distributions in the emission model? Are the VSP distributions developed in the city central business district (CBD) area applicable to its suburb area? In this context, this study examined the temporal and spatial consistency of the facility- and speed-specific VSP distributions in Beijing. The VSP distributions in different years and in different areas are developed, based on real-world vehicle activity data. The root mean square error (RMSE) is employed to quantify the difference between the VSP distributions. The maximum differences of the VSP distributions between different years and between different areas are approximately 20% of that between different road types. The analysis of the carbon dioxide (CO2) emission factor indicates that the temporal and spatial differences of the VSP distributions have no significant impact on vehicle emission estimation, with relative error of less than 3%.Implications: The temporal and spatial differences have no significant impact on the development of the facility- and speed-specific VSP distributions for the vehicle emission estimation. The database of the specific VSP distributions in the VSP-based emission models can maintain in terms of time. Thus, it is unnecessary to update the database regularly, and it is reliable to use the history vehicle activity data to forecast the emissions in the future. In one city, the areas with less data can still develop accurate VSP distributions based on better data from other areas. 相似文献
Antibiotics are widely used in daily life but their abuse has posed a potential threat to human health. To evaluate the toxicity of chloramphenicol (CAP) at the protein level, the interaction between CAP and human serum albumin (HSA) was investigated by fluorescence, Ultraviolet–visible (UV–Vis) absorption, Fourier transform infrared (FT-IR) spectroscopy and molecular docking methods. Fluorescence data revealed that the fluorescence quenching of HSA by CAP was the result of the formation of CAP–HSA complex, and the binding constant was determined to be 3.196?×?104 L mol?1 at 310 K. The thermodynamic determination indicated that the interaction was driven by enthalpy change and entropy change together, where the multiple hydrogen bonds (CAP and the residues Arg 222 and His 242 of HSA) and van der Waals forces were the dominant binding force. The site marker competition revealed that CAP bound into sub-domain IIA of HSA. The binding of CAP induced the drastic reduction in α-helix conformation and the significant enhancement in β-sheet conformation of HSA. Molecular docking study further confirmed the binding mode obtained by experimental study. This work provides a new quantitative evaluation method for antibiotics to cause the protein damage. 相似文献
New collecting and discharge electrode configurations are being used in electrostatic precipitators. In order to mathematically model preclpitators with these arrangements, it is necessary to develop reliable models of the field strength distributions of these electrodeplate geometries. This paper presents the concept of an equivalent wire diameter and attenuation functions, permitting use of the well-known wire-plate calculations. Experimental data presented in this paper shows the approximation techniques are sufficiently accurate. 相似文献