This review outlines nitrogen (N) responses in crop production and potential management decisions to ameliorate abiotic stresses for better crop production. N is a primary constituent of the nucleotides and proteins that are essential for life. Production and application of N fertilizers consume huge amounts of energy, and excess is detrimental to the environment. Therefore, increasing plant N use efficiency (NUE) is important for the development of sustainable agriculture. NUE has a key role in crop yield and can be enhanced by controlling loss of fertilizers by application of humic acid and natural polymers (hydrogels), having high water-holding capacity which can improve plant performance under field conditions. Abiotic stresses such as waterlogging, drought, heat, and salinity are the major limitations for successful crop production. Therefore, integrated management approaches such as addition of aminoethoxyvinylglycine (AVG), the film antitranspirant (di-1-p-menthene and pinolene) nutrients, hydrogels, and phytohormones may provide novel approaches to improve plant tolerance against abiotic stress-induced damage. Moreover, for plant breeders and molecular biologists, it is a challenge to develop cotton cultivars that can tolerate plant abiotic stresses while having high potential NUE for the future. 相似文献
Discharge of organic waste results in high nutrient pollution of the water bodies which is a major menace to the environment. A high quantity of nutrients such as ammonia causes a reduction in the dissolved oxygen level and induces algal growth in the water bodies. Water quality models have been the tools to evaluate the rate at which streams can disperse the pollutants they receive. Many water quality models are flawed either because of their inadequacy to completely simulate the advection component of the pollutant transport, or because of the limited application of the models, due to inaccurate estimation of model parameters. The hybrid cell in series (HCIS) developed by Ghosh et al. (2004) has been able to overcome such difficulties associated with the mixing cell-based models. Thus, the current study focuses on developing an analytical solution for the pollutant transport of the ammonia concentration through the plug flow, the first and second well-mixed cells of the HCIS model. The HCIS model coupled with the first order kinetic equation for ammonia nutrient was developed to simulate the ammonia pollutant concentration in the water column. The ammonia concentration at various points along the river system was assessed by considering the effects of the transformation of ammonia to nitrite, the uptake of ammonia by the algae, the respiration rate of the algae and the input of benthic source to the ammonia concentration in the water column. The proposed model was tested using synthetic data, and the HCIS-NH3 model simulations for spatial and temporal variation of ammonia pollutant transport were analysed. The simulated results of the HCIS-NH3 model agreed with the Fickian-based advection-dispersion equation (ADE) for simulating ammonia concentration solved using an explicit finite difference scheme. The HCIS-NH3 model also showed a good agreement with the observed data from the Umgeni River, except during rainy periods. 相似文献
Research on the influence of biosurfactants on the efficiency of in situ bioremediation of contaminated soil is continuously growing. Despite the constant progress in understanding the mechanisms involved in the effects of biosurfactants, there are still many factors that are not sufficiently elucidated. There is a lack of research on autochthonous or exogenous microbial metabolism when biostimulation or bioaugmentation is carried out to produce biosurfactants at contaminated sites. In addition, studies on the application of techniques that measure the biosurfactants produced in situ are needed. This is important because, although the positive influence of biosurfactants is often reported, there are also studies where no effect or negative effects have been observed. This review aimed to examine some studies on factors that can improve the production of biosurfactants in soils during in situ bioremediation. Moreover, this work reviews the methodologies that can be used for measuring the production of these biocomposts. We reviewed studies on the potential of biosurfactants to improve the bioremediation of hydrocarbons, as well as the limitations of methods for the production of these biomolecules by microorganisms in soil. 相似文献
A laboratory investigation of UV-C effects was conducted over a 62-h period: a much higher dose than in classic UV-C treatment was applied to five pigments and two painting binders used by prehistoric humans. Colorimetric parameters were compared to a control to see if UV-C can change pigment and binder color. Infrared spectroscopy, scanning electron microscopy, inductively coupled plasma and X-ray crystallography were also carried out to confirm colorimetric measurement. In order to understand how microorganism may physically deteriorate paintings, limestone blocks were painted and monitored until their complete colonization by algae, cyanobacteria, fungi and/or mosses. The results show that UV-C has no effect on mineral compounds. Conversely, it is noteworthy that binder color changed under both UV-C light conditions as well as in visible light. Concerning painted blocks, a fast proliferation has been observed with deterioration of the paintings. These results show the high importance of treating biofilm as soon as possible. Moreover, these findings may be a promising avenue inducing cave managers to use friendly UV-C light to treat contaminated cave paintings and also in the prevention of biodeterioration by lampenflora. 相似文献
Environmental Science and Pollution Research - Particulate matter with size less than or equal to 2.5 μm (PM2.5) samples were collected from an urban site Pune, India, during April... 相似文献
Environmental Science and Pollution Research - This work supports, for the first time, the integrated management of waste materials arising from industrial processes (fly ash from municipal solid... 相似文献
Green algae Cladophora aegagropila, present in cooling water of thermal power plants, causes many problems and complications, especially during summer. However, algae and its metabolites are rarely eliminated by common removal methods. In this work, the elimination efficiency of electrochemically prepared potassium ferrate(VI) on algae from cooling water was investigated. The influence of experimental parameters, such as Fe(VI) dosage, application time, pH of the system, temperature and hydrodynamics of the solution on removal efficiency, was optimized. This study demonstrates that algae C. aegagropila can be effectively removed from cooling water by ferrate. Application of ferrate(VI) at the optimized dosage and under the suitable conditions (temperature, pH) leads to 100% removal of green algae Cladophora from the system. Environmentally friendly reduction products (Fe(III)) and coagulation properties favour the application of ferrate for the treatment of water contaminated with studied microorganisms compared to other methods such as chlorination and use of permanganate, where harmful products are produced.
There is concern about the hazard of acute residential CO exposures from portable gasoline-powered generators, which can result in death or serious adverse health effects in exposed individuals. To address this hazard, the U.S. Consumer Product Safety Commission has developed low CO emission prototype generators by adapting off-the-shelf emission control technologies onto commercially available generators. A series of tests was conducted to characterize the indoor CO concentrations resulting from portable generators operating in the attached garage of a research house under seven different test house/garage configurations. The tested generators include both unmodified and modified low CO emission prototypes. It was found that CO concentrations varied widely, with peak house CO concentrations ranging from under 10 ppm to over 10,000 ppm. The highest concentrations in the house resulted from operation of the unmodified generator in the garage with the garage bay door closed and the house access door open. The lowest concentrations resulted from operation of a modified low CO emission prototype in the garage with the garage bay door open and the house access door closed. These tests documented reductions of up to 98% in CO concentrations due to emissions from two low CO emission portable generators compared to a stock generator.
Implications: Improper portable generator use has caused 800 U.S. deaths in the past 14 years. Generators operated in attached garages can cause CO to quickly reach deadly levels. Two low-emission prototypes generators were tested and had CO emissions reduced by up to 98%. Low-emission generators can reduce the risk of consumer poisonings and deaths. 相似文献
The sources of submicrometer particulate matter (PM1) remain poorly characterized in the industrialized city of Houston, TX. A mobile sampling approach was used to characterize PM1 composition and concentration across Houston based on high-time-resolution measurements of nonrefractory PM1 and trace gases during the DISCOVER-AQ Texas 2013 campaign. Two pollution zones with marked differences in PM1 levels, character, and dynamics were established based on cluster analysis of organic aerosol mass loadings sampled at 16 sites. The highest PM1 mass concentrations (average 11.6 ± 5.7 µg/m3) were observed to the northwest of Houston (zone 1), dominated by secondary organic aerosol (SOA) mass likely driven by nighttime biogenic organonitrate formation. Zone 2, an industrial/urban area south/east of Houston, exhibited lower concentrations of PM1 (average 4.4 ± 3.3 µg/m3), significant organic aerosol (OA) aging, and evidence of primary sulfate emissions. Diurnal patterns and backward-trajectory analyses enable the classification of airmass clusters characterized by distinct PM sources: biogenic SOA, photochemical aged SOA, and primary sulfate emissions from the Houston Ship Channel. Principal component analysis (PCA) indicates that secondary biogenic organonitrates primarily related with monoterpenes are predominant in zone 1 (accounting for 34% of the variability in the data set). The relevance of photochemical processes and industrial and traffic emission sources in zone 2 also is highlighted by PCA, which identifies three factors related with these processes/sources (~50% of the aerosol/trace gas concentration variability). PCA reveals a relatively minor contribution of isoprene to SOA formation in zone 1 and the absence of isoprene-derived aerosol in zone 2. The relevance of industrial amine emissions and the likely contribution of chloride-displaced sea salt aerosol to the observed variability in pollution levels in zone 2 also are captured by PCA.
Implications: This article describes an urban-scale mobile study to characterize spatial variations in submicrometer particulate matter (PM1) in greater Houston. The data set indicates substantial spatial variations in PM1 sources/chemistry and elucidates the importance of photochemistry and nighttime oxidant chemistry in producing secondary PM1. These results emphasize the potential benefits of effective control strategies throughout the region, not only to reduce primary emissions of PM1 from automobiles and industry but also to reduce the emissions of important secondary PM1 precursors, including sulfur oxides, nitrogen oxides, ammonia, and volatile organic compounds. Such efforts also could aid in efforts to reduce mixing ratios of ozone. 相似文献
The only documentation on the building downwash algorithm in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model), referred to as PRIME (Plume Rise Model Enhancements), is found in the 2000 A&WMA journal article by Schulman, Strimaitis and Scire. Recent field and wind tunnel studies have shown that AERMOD can overpredict concentrations by factors of 2 to 8 for certain building configurations. While a wind tunnel equivalent building dimension study (EBD) can be conducted to approximately correct the overprediction bias, past field and wind tunnel studies indicate that there are notable flaws in the PRIME building downwash theory. A detailed review of the theory supported by CFD (Computational Fluid Dynamics) and wind tunnel simulations of flow over simple rectangular buildings revealed the following serious theoretical flaws: enhanced turbulence in the building wake starting at the wrong longitudinal location; constant enhanced turbulence extending up to the wake height; constant initial enhanced turbulence in the building wake (does not vary with roughness or stability); discontinuities in the streamline calculations; and no method to account for streamlined or porous structures.
Implications: This paper documents theoretical and other problems in PRIME along with CFD simulations and wind tunnel observations that support these findings. Although AERMOD/PRIME may provide accurate and unbiased estimates (within a factor of 2) for some building configurations, a major review and update is needed so that accurate estimates can be obtained for other building configurations where significant overpredictions or underpredictions are common due to downwash effects. This will ensure that regulatory evaluations subject to dispersion modeling requirements can be based on an accurate model. Thus, it is imperative that the downwash theory in PRIME is corrected to improve model performance and ensure that the model better represents reality. 相似文献