全文获取类型
收费全文 | 64篇 |
免费 | 0篇 |
国内免费 | 1篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 3篇 |
环保管理 | 9篇 |
综合类 | 7篇 |
基础理论 | 9篇 |
污染及防治 | 25篇 |
评价与监测 | 4篇 |
社会与环境 | 3篇 |
灾害及防治 | 1篇 |
出版年
2023年 | 3篇 |
2022年 | 6篇 |
2021年 | 4篇 |
2020年 | 1篇 |
2019年 | 3篇 |
2018年 | 4篇 |
2017年 | 2篇 |
2016年 | 6篇 |
2015年 | 1篇 |
2014年 | 1篇 |
2013年 | 6篇 |
2012年 | 3篇 |
2011年 | 3篇 |
2008年 | 2篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2005年 | 3篇 |
2004年 | 3篇 |
2003年 | 2篇 |
2002年 | 1篇 |
2001年 | 1篇 |
1997年 | 1篇 |
1994年 | 1篇 |
1992年 | 1篇 |
1989年 | 1篇 |
1987年 | 1篇 |
1972年 | 1篇 |
1961年 | 1篇 |
排序方式: 共有65条查询结果,搜索用时 15 毫秒
11.
12.
Kelly KE Wagner DA Lighty JS Sarofim AF Bretecher B Holden B Helgeson N Sahay K Nardi Z 《Journal of the Air & Waste Management Association (1995)》2004,54(1):83-92
In-service diesel engines are a significant source of particulate matter (PM) emissions, and they have been subjected to increasingly strict emissions standards. Consequently, the wide-scale use of some type of particulate filter is expected. This study evaluated the effect of an Engelhard catalyzed soot filter (CSF) and a Rypos electrically heated soot filter on the emissions from in-service diesel engines in terms of PM mass, black carbon concentration, particle-bound polycyclic aromatic hydrocarbon concentration, and size distribution. Both filters capture PM. The CSF relies on the engine's exhaust to reach the catalyst regeneration temperature and oxidize soot, whereas the electrically heated filter contains a heating element to oxidize soot. The filters were installed on several military diesel engines. Particle concentrations and compositions were measured before and after installation of the filter and again after several months of operation. Generally, the CSF removed at least 90% of total PM, and the removal efficiency improved or remained constant after several months of operation. In contrast, the electrical filters removed 44-69% of PM mass. In addition to evaluating the soot filters, the sampling team also compared the results of several real-time particle measurement instruments to traditional filter measurements of total mass. 相似文献
13.
14.
Amir P. Nejadhashemi Joseph M. Sheridan Adel Shirmohammadi Hubert J. Montas 《Journal of the American Water Resources Association》2007,43(3):744-756
Abstract: Evaluating the relative amounts of water moving through the different components of the hydrological cycle is required for precise management and planning of water resources. An important aspect of this evaluation is the partitioning of streamflow into surface (quick flow) and base‐flow components. A prior study evaluated 40 different approaches for hydrograph‐partitioning on a field scale watershed in the Coastal Plain of the Southeastern United States and concluded that the Boughton’s method produced the most consistent and accurate results. However, its accuracy depends upon the proper estimation of: (1) the end of surface runoff, and (2) the fraction factor (α) that is function of many physical and hydrologic characteristics of a watershed. Proper identification of the end of surface runoff was accomplished by using a second derivative approach. Applying this approach to 12 years of separately measured surface and subsurface flow data from a field scale watershed (study area) proved to be accurate for 87% of the time. Estimation of the α value was accomplished in this study using two steps: (1) alpha was fitted to individual hydrographs: and, (2) a regression equation that determines these alpha values based on climatological factors (e.g., rainfall, evapotranspiration) was developed. Using these strategies improved the streamflow partitioning method’s performance significantly. 相似文献
15.
John Houlahan W. Andrew. Marcus Adel Shirmohammadi 《Journal of the American Water Resources Association》1992,28(3):553-567
ABSTRACT: This paper presents the results of an investigation of the effects of the Maryland Critical Area Act on generation of non-point source loads of phosphorus, nitrogen, and sediment to the Rhode River estuary. The Simple Method model, the Marcus and Kearney regression model, and the CREAMS model were used to estimate annual loads under: (1) present conditions, (2) maximum land use development allowable under the Act, and (3) two sets of future land use conditions that might occur if the Act were not in place. Results indicate that the Critical Area Act can reduce the present generation of nonpoint nutrient and sediment loadings 20–30 percent from the regulated area. These reductions can occur while preserving agricultural lands and allowing limited residential and urban development. The decrease in nutrient loadings is primarily dependent upon implementation and enforcement of agricultural best management practices (BMPs). The BMPs could reduce present agricultural nutrient loadings by 90 percent to a level comparable to loadings from residential areas. The estimated effectiveness of the Critical Area Act is even greater when compared to potential future nutrient loadings if development in the area remains unregulated. Unrestricted residential and urban development could increase nutrient loadings by 200 percent to 1000 percent as compared to controlled development under Critical Area Act guidelines. The Critical Area Act primarily prevents these future increases by severely limiting woodland cutting, with lesser results obtained by requiring urban BMPs. 相似文献
16.
17.
Advanced oxidation technologies are a friendly environmental approach for the remediation of industrial wastewaters. Here, one pot synthesis of mesoporous WO_3 and WO_3-graphene oxide(GO) nanocomposites has been performed through the sol–gel method. Then, platinum(Pt) nanoparticles were deposited onto the WO_3 and WO_3-GO nanocomposite through photochemical reduction to produce mesoporous Pt/WO_3 and Pt/WO_3-GO nanocomposites. X-ray diffraction(XRD) findings exhibit a formation of monoclinic and triclinic WO_3 phases. Transmission Electron Microscope(TEM) images of Pt/WO_3-GO nanocomposites exhibited that WO_3 nanoparticles are obviously agglomerated and the particle sizes of Pt and WO_3 are ~ 10 nm and 20–50 nm, respectively. The mesoporous Pt/WO_3 and Pt/WO_3-GO nanocomposites were assessed for photocatalytic degradation of Methylene Blue(MB) as a probe molecule under visible light illumination.The findings showed that mesoporous Pt/WO_3, WO_3-GO and Pt/WO_3-GO nanocomposites exhibited much higher photocatalytic efficiencies than the pure WO_3. The photodegradation rates by mesoporous Pt/WO_3-GO nanocomposites are 3, 2 and 1.15 times greater than those by mesoporous WO_3, WO_3-GO, and Pt/WO_3, respectively. The key factors of the enhanced photocatalytic performance of Pt/WO_3-GO nanocomposites could be explained by the highly freedom electron transfer through the synergetic effect between WO_3 and GO sheets, in addition to the Pt nanoparticles that act as active sites for O2 reduction, which suppresses the electron hole pair recombination in the Pt/WO_3-GO nanocomposites. 相似文献
18.
AL-Fahdawi Ahmed A. H. Rabee Adel M. Al-Hirmizy Shaheen M. 《Environmental monitoring and assessment》2015,187(6):1-17
Environmental Monitoring and Assessment - A good quality drinking water is essential for human survival. However, a large percentage of the populations in most developing countries (Nigeria... 相似文献
19.
20.
In semi-arid areas like the Kairouan region, salinization has become an increasing concern because of the constant irrigation with saline water and over use of groundwater resources, soils, and aquifers. In this study, a methodology has been developed to evaluate groundwater contamination risk based on the unsaturated zone hydraulic properties. Two soil profiles with different ranges of salinity, one located in the north of the plain and another one in the south of plain (each 30 m deep) and both characterized by direct recharge of the aquifer, were chosen. Simulations were conducted with Hydrus-1D code using measured precipitation data for the period 1998–2003 and calculated evapotranspiration for both chosen profiles. Four combinations of initial conditions of water content and salt concentration were used for the simulation process in order to find the best match between simulated and measured values. The success of the calibration of Hydrus-1D allowed the investigation of some scenarios in order to assess the contamination risk under different natural conditions. The aquifer risk contamination is related to the natural conditions where it increased while facing climate change and temperature increase and decreased in the presence of a clay layer. Hydrus-1D was a useful tool to predict the groundwater level and quality in the case of a direct recharge and in the absence of any information related to the soil layers except for the texture. 相似文献