全文获取类型
收费全文 | 134篇 |
免费 | 0篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 22篇 |
环保管理 | 15篇 |
综合类 | 17篇 |
基础理论 | 16篇 |
污染及防治 | 26篇 |
评价与监测 | 28篇 |
社会与环境 | 6篇 |
出版年
2023年 | 5篇 |
2022年 | 6篇 |
2021年 | 5篇 |
2020年 | 3篇 |
2019年 | 1篇 |
2018年 | 6篇 |
2017年 | 7篇 |
2016年 | 3篇 |
2015年 | 2篇 |
2014年 | 5篇 |
2013年 | 15篇 |
2012年 | 6篇 |
2011年 | 7篇 |
2010年 | 11篇 |
2009年 | 10篇 |
2008年 | 6篇 |
2007年 | 6篇 |
2006年 | 12篇 |
2005年 | 3篇 |
2004年 | 9篇 |
2003年 | 1篇 |
2002年 | 2篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1999年 | 1篇 |
排序方式: 共有134条查询结果,搜索用时 15 毫秒
71.
Kelleci Orhan Aydemir Deniz Altuntas Ertuğrul Kurt Rıfat Oztel Ahmet Yorur Hüseyin Istek Abdullah 《Journal of Polymers and the Environment》2022,30(7):3091-3106
Journal of Polymers and the Environment - The aim of this study was to investigate the physical, mechanical, morphological, structural, and thermal properties of polylactic acid (PLA) and... 相似文献
72.
Çağatay Tanrıverdi Ahmet Alp Ali Rıza Demirkıran Fatih Üçkardeş 《Environmental monitoring and assessment》2010,167(1-4):175-184
In this study, surface water quality of the Ceyhan River basin were assessed and examined with 13 physico-chemical parameters in 31 stations in 3 months during the period of 2005. Multivariate statistical techniques were applied to identify characteristics of the water quality in the studied stations. Nutrients, Cl??? and Na?+? affected mostly to the stations of Erkenez 2, S?r 2, and S?r 3 in the ordination diagram of correspondence analysis. Three factors were extracted by principal component analysis, which explains 79.14% of the total variation. The first factor (PC1) captures variables of EC, DO, NO $_{2}^{\; -}$ , PO $_{4}^{\; \equiv }$ , Cl???, SO $_{4}^{\; =}$ , Na?+?, and Ca?+?+?. The second factor (PC2) is significantly related to pH, NH $_{3}^{\; -}$ , and Mg?+?+?, while water temperature (T) and NO $_{3}^{\; -}$ accounted for the greatest loading for factor 3 (PC3). The stations were divided into three groups for PC1, two groups for PC2, and three groups for PC3 by hierarchical cluster analysis. The stations in the vicinity of cities presented low dissolved oxygen and high concentration of physico-chemical parameter levels. The stations of Erkenez 2, S?r 2, S?r 3, and Aksu 4 located near the city of Kahramanmara? were characterized by an extremely high pollution due to discharge of wastewater from industry and domestic. P?narba?? and Elbistan stations were also influenced by household wastewater of the city of Elbistan. According to criteria of Turkish Water Pollution Control Regulation, Erkenez 2, S?r 2, and S?r 3 stations have high polluted water. This study suggests that it is urgent to control point pollutions, and all wastewater should be purified before discharge to the Ceyhan River basin. 相似文献
73.
In this study, two pilot-scale aerobic landfill reactors with (A1) and without (A2) leachate recirculation are used to obtain
detailed information on the quantity and quality of leachate in aerobic landfills. The observed parameters of leachate quality
are pH, chloride (Cl−), chemical oxygen demand (COD), biological oxygen demand (BOD), total Kjeldahl nitrogen (TKN), ammonia nitrogen (NH3-N), and nitrate (NO3–-N). pH values of the leachate increased to 7 after 50 days in reactor A1 and after 70 days in reactor A2. Cl− concentrations increased rapidly to 6100 (A1) and 6900 (A2) mg/L after 80 days, from initial values of 3000 and 2800 mg/L,
respectively. COD and BOD values decreased rapidly in the A1 landfill reactor, indicating the rapid oxidation of organic matter.
The BOD/COD ratio indicates that leachate recirculation slightly increases the degradation of solid waste in aerobic landfills.
NH3-N concentrations decreased as a result of the nitrification process. Denitrification occurred in parts of the reactors as
a result of intermittent aeration; this process causes a decrease in NO3− concentrations. There is a marked difference between the A1 and A2 reactors in terms of leachate quantity. Recirculated leachate
made up 53.3% of the leachate generated from the A1 reactor during the experiment, while leachate quantity decreased by 47.3%
with recirculation when compared with the aerobic dry landfill reactor. 相似文献
74.
Turna I Yahyaoglu Z Yüksek F Ayaz FA Guney D 《Journal of environmental biology / Academy of Environmental Biology, India》2006,27(3):491-497
The genetic variation in populations of Anatolian black pine (Pinus nigra Arn. subsp. pallasiana (L.) Holmboe.), one of the species covering large areas in Turkey, was investigated. Open pollinated seeds were collected from 13 populations in a natural distribution range. Six characters of seeds (length, width, ratio of length to width, weight/1000 seeds) and seedling characters (cotyledon number and hypocotyls height) and two enzyme systems viz. leucine aminopeptidase (LAP) and glutamate oxaloacetate transaminase, (GOT) were investigated. Significant differences were detected among the populations for the morphological characters. In addition, isozyme patterns of two enzyme systems revealed that LAP has two loci (one with 2 alleles and the other with 3), while GOT has three loci (two with 3 alleles and the third one with 2 alleles). Polymorphic loci were 74% on the average. The mean number of alleles per loci was 1.94 and expected heterozygosity was 19%. The mean total genetic diversity was calculated as 0.203; the mean gene diversity within populations was determined as 0.188, and the average between subpopulations diversity was 0.016. The relative magnitude of genetic differentiation among subpopulations was measured as 0.074 indicating that only 7.4% of the total genetic diversity was there between populations. Average genetic distance was 0.093 according to Gregorius. Nei's genetic distance was 0.022. 相似文献
75.
Demirak A Balci A Karaoğlu H Tosmur B 《Environmental monitoring and assessment》2006,123(1-3):271-283
In this study, chemical composition of the rain water in Mugla was investigated from February to April 2002. Rain water samples were obtained from Mugla, a small city in south western Turkey. The Yatagan Power Plant is located 30 km northwest of Mugla city. The values of pH and the concentrations of major ions (Ca2+, Na+, K+, SO4
2−, NO3
−, NH4
+) in the rainwater samples were analyzed. The pH varied from 4.5 to 7.7 with an average of 6.9 which was in alkaline range considering 5.6 as the neutral pH of cloud water with atmospheric CO2 equilibrium. In the total 30 rain events, only two events were observed in acidic range (< 5.6) which occurred after continuous rains. The equivalent concentration of components followed the order: Ca2+ > SO4
2− > NH4
+ > NO3
− > Na+ > K+ > H+. The volume-weighted mean (VWM) of the measured ionic sum is 371.62 μeq/l. The ratio of between sum cations and sum anions (∑cations /∑ anions) is 1.52 μeq/l. The alkaline components (Ca2+, Na+, K+) contribute 52%, NH4
+ 8%, whereas, the contribution from the acidic components is relatively small (40%). The low concentrations of H+ found in rainwater samples from Mugla suggest that an important portion of H2SO4 and HNO3 have been neutralized by alkaline particles in the atmosphere. The dust-rich local and surrounding limestone environment might have caused the high concentration of Ca2+ in Mugla area. The relatively high concentration of NH4
+ observed at Mugla is suspected to be due to surrounding agricultural. The results obtained in this study are compared with those other studies conducted at various places in the world. 相似文献
76.
An experimental study of air entrainment and oxygen transfer at a water jet from a nozzle with air holes. 总被引:3,自引:0,他引:3
An adequate supply of dissolved oxygen is important in natural rivers and in some water treatment processes. The dissolved oxygen concentration can be enhanced by entraining air bubbles in a receiving pool. When a water jet impinges a receiving pool at rest, air bubbles may be entrained and carried away below the pool free surface. This process is called plunging water jet entrainment and aeration. This paper describes an experimental study of the air entrainment rate and oxygen transfer efficiency of circular nozzles with and without air holes. In particular, the effect of varying the number, positions, and open/close status of the air holes is investigated. A negative pressure occurred depending on the air holes opened on the circular nozzles. This phenomenon affected the water jet expansion, water jet shape, air entrainment, and bubble penetration depth and, hence, the oxygen transfer efficiency. It was demonstrated that the air entrainment rate and the oxygen transfer efficiency of the circular nozzles with air holes were better than those of the circular nozzles without air holes. Therefore, adding air holes to a simple, circular nozzle could lead to a significantly increased air entrainment rate and oxygen transfer efficiency. 相似文献
77.
Iri Ahmet H. Shahrah Malek H. A. Ali Ali M. Qadri Sayed A. Erdem Talha Ozdur Ibrahim T. Icoz Kutay 《Environmental science and pollution research international》2021,28(45):63860-63866
Environmental Science and Pollution Research - Unfortunately, the plastic pollution increases at an exponential rate and drastically endangers the marine ecosystem. According to World Health... 相似文献
78.
79.
The effects of solar radiation and temperature on bacterial die-off rates in Black Sea coastal waters using total coliform as the indicator organism were studied. Coliform die-off experiments were carried out in seawater samples collected along the coastline. The experiments were conducted in beakers filled with seawater that were kept at constant temperatures and exposed to solar radiation. The membrane filter technique was used for the coliform analysis. Temperature ranging between 9 and 26 degrees C and solar radiation between 20 and 60 cal/cm(2) h were tested. Experiments in the dark were also conducted to isolate the effect of solar radiation from the other factors and, furthermore, to determine the effect of temperature on bacterial die-off. The solar radiation was found to be the most significant factor affecting the mortality of coliform bacteria. 相似文献
80.
The purpose of this study was to determine the concentration, in terms of monthly and seasonal distribution and in relation to meteorological factors, of indoor and outdoor microfungi at selected sites in several child day care centers in the city of Edirne, Turkey. Samples were collected at one month intervals over a period of 12 months between January-December 2004, by exposing petri plates containing Peptone Dextrose Agar with Rose-Bengal and Streptomycin medium to the air for 10-15 min. A total of 2,071 microfungal colonies were counted on 192 petri plates. Thirty microfungal genera (Acremonium, Alternaria, Arthrinium, Aspergillus, Bahusakala, Beauveria, Ceuthospora, Chaetomium, Cladosporium, Curvularia, Drechslera, Epicoccum, Eurotium, Fusarium, Mycotypha, Myrotechium, Paecilomyces, Penicillium, Pestalotiopsis, Phoma, Ramichloridium, Rhizopus, Scopulariopsis, Stachybotrys, Stemphylium, Torula, Trichoderma, Trichothecium, Ulocladium, Verticillium) and 75 microfungal species were isolated from the air indoor and outdoor of the day care centers. The dominant microfungal genera were Cladosporium, Penicillium and Alternaria (44.11%, 18.94%, 14.67% of the total respectively), while the genus with the most species richness was Penicillium (26 species). Alternaria, Cladosporium, Penicillium and non-sporulating microfungi were found every month. Cladosporium was the dominant genus in both indoor and outdoor air. Although the predominant genus was the same in both indoor and outdoor air, Cladosporium was followed by Penicillium, Alternaria and Aspergillus genera in indoor air and by Alternaria, Penicillium and Aspergillus genera in outdoor air. While a positive correlation was found between the concentration of monthly outdoor microfungi and monthly average temperature, a negative correlation was found between the concentration of monthly outdoor microfungi and monthly average wind velocity. Also, some relationships were found between the monthly concentrations of the most predominant microfungal genera (Cladosporium, Penicillium and Alternaria) and various meteorological factors. 相似文献