首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   0篇
废物处理   3篇
环保管理   4篇
综合类   3篇
基础理论   4篇
污染及防治   1篇
评价与监测   6篇
  2022年   2篇
  2019年   2篇
  2016年   1篇
  2013年   2篇
  2012年   1篇
  2010年   1篇
  2009年   4篇
  2008年   2篇
  2006年   1篇
  2005年   1篇
  2003年   2篇
  1961年   1篇
  1960年   1篇
排序方式: 共有21条查询结果,搜索用时 125 毫秒
11.
12.

An appraisal of seawater intrusion into the coastal aquifers is one of the major issues for groundwater resource management. The GALDIT model applies to the analysis of multiple parameters using systematic GIS techniques for mapping and assessment of seawater intrusion vulnerability. It demarcates the mapping of potential vulnerability that shows a higher vulnerability to seawater intrusion in various parts of the coast and the estimated vulnerability index value of 7.50 and 9.64. An area of 33.0 km2 spread in the low-lying coastal area comprising estuaries, salt marshes, and saltpans shows the high vulnerability condition with an estimated vulnerability value of 6.42–7.50. An area of 73.20 km2 spread over coastal and alluvial plains experiences moderate vulnerability (temporal salinity in the groundwater sources) with an estimated vulnerability index value of 5.46–6.42. Aquifers underlying coastal uplands (hard rock formations) and some parts of accretionary beaches (2.05 km2) are relatively protected fresh groundwater sources, wherein the estimated vulnerability index is 4.55–5.46. The vulnerability mapping of the GALDIT model using hydrochemical analysis of primary groundwater parameters such as TDS, Cl?, HCO3, and Cl?/HCO3 ratio is validated. Higher concentration of TDS (2637–4162 mg/l) and Cl? (1268–2347 mg/l) is taken for the areas falling under higher vulnerability to seawater intrusion, especially in the placer mining sites and coastal areas facing erosion. Similarly, the groundwater sources of the low-lying areas including estuaries, salt marshes, saltpans, and backwater were noted to have higher values of Cl?/HCO3 with a rationality of 9.87–12.18. Hydrological facies shows the highest concentration of NaCl in the groundwater sources within the proximity of eroded beaches, saltwater bodies, and sand mining areas. A hydrochemical facies evolution (HFE) diagram represents the hydrochemical facies of groundwater elements that shows an intrusion of seawater into the coastal aquifers underlying the very high vulnerable zones. Higher bicarbonate concentration (233–318 mg/l) is noticed in the upland areas and some parts of dunes and accreted beaches, sandy coasts, and uplands. Vulnerability analysis reveals that those areas near saltwater bodies and eroding coasts are prone to lateral and vertical diffusion of saltwater. The geodatabase developed through such modeling studies can help in planning and developing activities for sustainable groundwater resource management in coastal areas.

  相似文献   
13.
The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 +/- 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 +/- 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7-20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.  相似文献   
14.
Most of the current CO2 capture technologies are associated with large energy penalties that reduce their economic viability. Efficiency has therefore become the most important issue when designing and selecting power plants with CO2 capture. Other aspects, like reliability and operability, have been given less importance, if any at all, in the literature.This article deals with qualitative reliability and operability analyses of an integrated reforming combined cycle concept. The plant reforms natural gas into a syngas, the carbon is separated out as CO2 after a water-gas shift section, and the hydrogen-rich fuel is used for a gas turbine. The qualitative reliability analysis in the article consists of a functional analysis followed by a failure mode, effects, and criticality analysis (FMECA). The operability analysis introduces the comparative complexity indicator (CCI) concept.Functional analysis and FMECA are important steps in a system reliability analysis, as they can serve as a platform and basis for further analysis. Also, the results from the FMECA can be interesting for determining how the failures propagate through the system and their effects on the operation of the process. The CCI is a helpful tool in choosing the level of integration and to investigate whether or not to include a certain process feature. Incorporating the analytical approach presented in the article during the design stage of a plant can be advantageous for the overall plant performance.  相似文献   
15.

In this article, flexural, impact and dynamic mechanical properties of the Pineapple leaf fibres (PALF) and Washingtonia trunk fibres (GW) based bio-phenolic hybrid composites were examined. The pure and hybrid composites were fabricated using the hand lay-up technique with an overall fibre weight ratio of 50% in which GW and PALF were maintained in the fibre weight ratios of 50:50, 30:70, and 70:30 denoted as 1G1P, 3G7P, and 7G3P, respectively. Hybrid composites displayed better flexural strength, flexural modulus and impact strength than the GW composites and better viscoelastic properties than the PALF composites. Results revealed that 1G1P hybrid composites exhibited 25% and 12% improvements in flexural strength and modulus compared to the GW composites. 3P7K composites showed a twofold increase in impact strength than GW composites. The storage modulus of the pure and hybrid composites declined rapidly beyond the glass transition temperature. Furthermore, it was observed that the values of storage modulus for all the composites at 150 °C were similar regardless of the composite configuration. The Peak of loss modulus was found to increase in the following order: GW?>?7G3P?>?3G7P?>?1G1P?>?PALF. Furthermore, the temperature at the peak tan delta was improved, and a reduction in the tan delta peak was observed for hybrid composites compared to the pure composites. Finally, the PALF and GW hybrid combinations can be suitable for use in various applications such as textiles, machinery part production industries, medicine, automobiles, etc.

  相似文献   
16.
Groundwater quality assessment has been carried out based on physicochemical parameters (pH, EC, TDS, CO(3), HCO(3), Cl, SO(4), PO(4), NO(2), Ca(+2), Mg(+2), Na(+) and K(+)) and metal concentration in the Rameswaram Island from 25 bore wells. The Langelier Saturation Index of the groundwater shows positive values (63% samples) with a tendency to deposit the CaCO(3) in the majority of water samples. Scatter plot (Ca + Mg/HCO(3)) suggests carbonate weathering process, which is the main contributor of Ca(2+), Mg(2+) and HCO(3) ions to the water. Gibbs diagram suggests rock-water interaction dominance and evaporation dominance which are responsible for the change in the quality of water in the study area. NaCl and mixed CaNaHCO(3) facies are two main hydrogeochemical facies of groundwater. Mathematical calculations and graphical plots of geochemical data reveal that the groundwater of Rameswaram Island is influenced by natural weathering of rocks, anthropogenic activities and seawater intrusion due to over exploitation. Weathering and dissolution of carbonate and gypsum minerals also control the concentration of major ions (Ca(+2), Mg(+2), Na(+) and K(+)) in the groundwater. The nutrient concentration of groundwater is controlled to a large extent by the fertilizers used in agricultural lands and aquaforms. Comparison of geochemical data shows that majority of the groundwater samples are suitable for drinking water and irrigation purposes.  相似文献   
17.
Two spectrophotometric methods have been developed for the determination of nitrite using dapsone (DAP) with alpha-naphthol and 4-amino-5-hydroxynapthalene-2,7-disulphonic acid monosodium salt (AHNDMS) as chromogenic reagents with maximum absorbance wavelength at 540 and 520 nm respectively. For the method that utilizes dapsone with alpha-naphthol (DAP-alpha-naphthol), the beer's law range is obeyed between 0.05-0.8 microg ml(-1) with molar absorptivity of 5.749 x 104 l mol(-1) cm(-1). The second method that uses dapsone with AHNDMS (DAP-AHNDMS), the beer's law is valid over the range 0.2-1.4 mug ml(-1) and molar absorptivity 2.44 x 104 l mol(-1) cm(-1). The common interfering ions in the analytical procedures have been studied. This proposed methods are reliable, reproducible and have been successfully applied to determine nitrite in various water sources of environmental interest.  相似文献   
18.
This study presents a comparison of different concepts for delivering combined heat and power (CHP) to a refinery in Norway. A reference case of producing high pressure steam from natural gas in boilers and electricity in a combined cycle power plant, is compared to a: (1) natural gas fueled CHP without any CO2 capture; (2) hydrogen fueled CHP with hydrogen produced from steam methane reforming (SMR); (3) hydrogen fueled CHP with hydrogen produced from autothermal reforming (ATR); and finally (4) natural gas fueled CHP with postcombustion CO2 removal. The options are compared on the basis of first law efficiency, emissions of CO2 and a simplified cash flow evaluation. Results show that in terms of efficiency the standard natural gas fueled CHP performs better than the reference case as well as the options with carbon capture. The low carbon options in turn offer lower emissions of greenhouse gases while maintaining the same efficiency as the reference case. The cash flow analysis shows that for any option, a certain mix of prices is required to produce a positive cash flow. As expected, the relationship between natural gas price and electricity price affects all options. Also the value of heat and CO2 emissions plays an important role.  相似文献   
19.
In this study, a cycle designed for capturing the greenhouse gas CO2 in a natural gas combined cycle power plant has been analyzed. The process is a pre-combustion CO2 capture cycle utilizing reforming of natural gas and removal of the carbon in the fuel prior to combustion in the gas turbine. The power cycle consists of a H2-fired gas turbine and a triple pressure steam cycle. Nitrogen is used as fuel diluent and steam is injected into the flame for additional NOx control. The heat recovery steam generator includes pre-heating for the various process streams. The pre-combustion cycle consists of an air-blown auto-thermal reformer, water–gas shift reactors, an amine absorption system to separate out the CO2, as well as a CO2 compression block. Included in the thermodynamic analysis are design calculations, as well as steady-state off-design calculations. Even though the aim is to operate a plant, as the one in this study, at full load there is also a need to be able to operate at part load, meaning off-design analysis is important. A reference case which excludes the pre-combustion cycle and only consists of the power cycle without CO2 capture was analyzed at both design and off-design conditions for comparison. A high degree of process integration is present in the cycle studied. This can be advantageous from an efficiency stand-point but the complexity of the plant increases. The part load calculations is one way of investigating how flexible the plant is to off-design conditions. In the analysis performed, part load behavior is rather good with efficiency reductions from base load operation comparable to the reference combined cycle plant.  相似文献   
20.
Background culturable bacteria aerosols were collected and identified in two large public buildings located in Minneapolis, Minnesota and Seattle, Washington over a period of 5 months and 3 months, respectively. The installed particulate air filters in the ventilation systems were used as the aerosol sampling devices at each location. Both pre and final filters were collected from four air handing units at each site to determine the influence of location within the building, time of year, geographical location and difference between indoor and outdoor air. Sections of each loaded filter were eluted with 10 ml of phosphate buffered saline (PBS). The resulting solutions were cultured on blood agar plates and incubated for 24 h at 36 degrees C. Various types of growth media were then used for subculturing, followed by categorization using a BioLog MicroStation (Biolog, Hayward, CA, USA) and manual observation. Environmental parameters were gathered near each filter by the embedded on-site environmental monitoring systems to determine the effect of temperature, humidity and air flow. Thirty nine different species of bacteria were identified, 17 found only in Minneapolis and 5 only in Seattle. The hardy spore-forming genus Bacillus was the most commonly identified and showed the highest concentrations. A significant decrease in the number of species and their concentration occurred in the Minneapolis air handling unit supplying 100% outdoor air in winter, however no significant correlations between bacteria concentration and environmental parameters were found.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号