首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   0篇
安全科学   2篇
环保管理   1篇
综合类   4篇
基础理论   5篇
污染及防治   22篇
  2023年   1篇
  2022年   5篇
  2021年   2篇
  2019年   2篇
  2018年   2篇
  2016年   1篇
  2014年   1篇
  2013年   4篇
  2012年   2篇
  2011年   4篇
  2010年   1篇
  2008年   3篇
  2007年   1篇
  2006年   3篇
  2005年   1篇
  1992年   1篇
排序方式: 共有34条查询结果,搜索用时 0 毫秒
31.
The paper proposes an imprecise Fault Tree Analysis in order to characterize systems affected by the lack of reliability data. Differently from other research works, the paper introduces a classification of basic events into two categories, namely Initiators and Enablers. Actually, in real industrial systems some events refer to component failures or process parameter deviations from normal operating conditions (Initiators), whereas others refer to the functioning of safety barriers to be activated on demand (Enablers). As a consequence, the output parameter of interest is not the classical probability of occurrence of the top event, but its Rate of OCcurrence (ROCOF) over a stated period of time. In order to characterize the basic events, interval-valued information supplied by experts are properly aggregated and propagated to the top. To this purpose, the Dempster–Shafer Theory of evidence is proposed as a more appropriate mathematical framework than the classical probabilistic one. The proposed methodology, applied to a real industrial scenario, can be considered a helpful tool to support risk managers working in industrial plants.  相似文献   
32.
A promising alternative to conventional single phase processing, the use of sequential anaerobic-aerobic digestion, was extensively investigated on municipal sewage sludge from a full scale wastewater treatment plant. The objective of the work was to evaluate sequential digestion performance by testing the characteristics of the digested sludge in terms of volatile solids (VS), Chemical Oxygen Demand (COD) and nitrogen reduction, biogas production, dewaterability and the content of proteins and polysaccharides. VS removal efficiencies of 32% in the anaerobic phase and 17% in the aerobic one were obtained, and similar COD removal efficiencies (29% anaerobic and 21% aerobic) were also observed. The aerobic stage was also efficient in nitrogen removal providing a decrease of the nitrogen content in the supernatant attributable to nitrification and simultaneous denitrification. Moreover, in the aerobic phase an additional marked removal of proteins and polysaccharides produced in the anaerobic phase was achieved. The sludge dewaterability was evaluated by determining the Optimal Polymer Dose (OPD) and the Capillary Suction Time (CST) and a significant positive effect due to the aerobic stage was observed. Biogas production was close to the upper limit of the range of values reported in the literature in spite of the low anaerobic sludge retention time of 15 days. From a preliminary analysis it was found that the energy demand of the aerobic phase was significantly lower than the recovered energy in the anaerobic phase and the associated additional cost was negligible in comparison to the saving derived from the reduced amount of sludge to be disposed.  相似文献   
33.
Human enteroviruses (HEVs) occur in high concentrations in wastewater and can contaminate receiving environmental waters, constituting a major cause of acute waterborne disease worldwide. In this study, we investigated the relative abundance, occurrence, and seasonal distribution of polio and other enteroviruses at three wastewater treatment plants (WWTPs) in Naples, Southern Italy, from January 2010 to December 2014. Influent and effluent samples from the three WWTPs were collected monthly. One hundred and sixty-one of the 731 wastewater samples collected (22.0%) before and after water treatment were CPE positive on RD cells; while no samples were positive on L20B cells from any WWTPs. Among the 140 non-polio enterovirus isolated from inlet sewage, 69.3% were Coxsackieviruses type B and 30.7% were Echoviruses. Among these, CVB3 and CVB5 were most prevalent, followed by CVB4 and Echo6. The twenty-one samples tested after treatment contained 6 CVB4, 5 CVB3, 3 Echo11, and 2 Echo6; while other serotypes were isolated less frequently. Data on viral detection in treated effluents of WWTPs confirmed the potential environmental contamination by HEVs and could be useful to establish standards for policies on wastewater management.  相似文献   
34.
Within the initiatives for poliomyelitis eradication by WHO, Italy activated an environmental surveillance (ES) in 2005. ES complements clinical Acute Flaccid Paralysis (AFP) surveillance for possible polio cases, detects poliovirus circulation in environmental sewage, and is used to monitor transmission in communities. In addition to polioviruses, the analyses comprised: (i) the monitoring of the presence of non-polio enteroviruses in sewage samples and (ii) the temporal and geographical distribution of the detected viruses. From 2009 to 2015, 2880 sewage samples were collected from eight cities participating in the surveillance. Overall, 1479 samples resulted positive for enteroviruses. No wild-type polioviruses were found, although four Sabin-like polioviruses were detected. The low degree of mutation found in the genomes of these four isolates suggests that these viruses have had a limited circulation in the population. All non-polio enteroviruses belonged to species B and the most frequent serotype was CV-B5, followed by CV-B4, E-11, E-6, E-7, CV-B3, and CV-B2. Variations in the frequency of different serotypes were also observed in different seasons and/or Italian areas. Environmental surveillance in Italy, as part of the ‘WHO global polio eradication program’, is a powerful tool to augment the polio surveillance and to investigate the silent circulation or the re-emergence of enteroviruses in the population.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号