Species turnover patterns can be inconsistent due to differences in the dispersal ability of different growth forms. Here, species of trees, shrubs, herbs, and bryophytes in the Xiaoqinling National Nature Reserve in China were analyzed to determine patterns of species turnover along an elevation and spatial gradient. Variance partitioning was used to assess the relative contribution of topographic heterogeneity and dispersal limitation to species turnover. Our results suggest that the effect of dispersal limitation is more important than topographic heterogeneity on species turnover in temperate mountane ecosystems in the study area. Dispersal limitation has a greater effect on trees species turnover than on shrubs, herbs or bryophytes species turnover. 相似文献
Abstract: In Central Europe invasive North American crayfishes are carriers of the oomycete Aphanomyces astaci, which causes crayfish plague. This lethal disease currently represents one of the major threats to native European crayfishes. We used molecular methods—species-specific amplification and sequencing of the pathogen DNA—to investigate the prevalence of individuals latently infected with A. astaci in 28 populations of two invasive American crayfish species (6 of the signal crayfish [ Pacifastacus leniusculus ] and 22 of the spiny-cheek crayfish [ Orconectes limosus ]) in the Czech Republic. The pathogen occurred in 17 investigated populations. We recorded a high variation in positive reactions, ranging from 0% to 100%, in populations of O. limosus . In P. leniusculus, however, only one individual out of 124 tested positive for the pathogen. There was a clear relationship between the water body type and pathogen prevalence in O. limosus . Infection ratios in isolated standing waters were usually low, whereas in running waters, pathogen prevalence often exceeded 50%. Other evaluated characteristics of potential plague pathogen carriers (size, sex, and the presence of melanized spots in the cuticle) seemed to be unrelated to infection. Our data suggest that in contrast to other European countries, O. limosus seems to be the primary reservoir of crayfish plague in the Czech Republic. Although all populations of alien American crayfishes may be potential sources of infections and should be managed as such, knowledge on the prevalence of the plague pathogen at various localities may allow managers to focus conservation efforts on the most directly endangered populations of native crayfishes. 相似文献
Environmental Economics and Policy Studies - While the EU is working toward the implementation of the world’s first Carbon Border Adjustment (CBA) Mechanism, a gap remains between the ways in... 相似文献
Regional Environmental Change - Replacement of conventional energy sources with renewables such as solar panels and wind turbines requires adequate land. Impact assessments should be conducted to... 相似文献
The interest in biomass fuel is continuing to expand globally and in the northeastern United States as wood pellets are becoming a primary source of fuel for residential and small commercial systems. Wood pellets for boilers are often stored in basement storage rooms or large bag-type containers. Due to the enclosed nature of these storage areas, the atmosphere may exhibit increased levels of carbon monoxide. Serious accidents in Europe have been reported over the last decade in which high concentrations of carbon monoxide (CO) have been found in or near bulk pellet storage containers. The aim of this study was to characterize the CO concentrations in areas with indoor storage of bulk wood pellets. Data was obtained over approximately 7 months (December 2013 to June 2014) at 25 sites in New Hampshire and Massachusetts: 16 homes using wood pellet boilers with indoor pellet storage containers greater than or equal to 3 ton capacity; 4 homes with wood pellet heating systems with outdoor pellet storage; 4 homes using other heating fuels; and a university laboratory site. CO monitors were set up in homes to collect concentrations of CO in the immediate vicinity of wood pellet storage containers, and data were then compared to those of homes using fossil fuel systems. The homes monitored in this study provided a diverse set of housing stock spanning two and a half centuries of construction, with homes built from 1774 to 2013, representing a range of air exchange rates. The CO concentration data from each home was averaged hourly and then compared to a threshold of 9 ppm. While concentrations of CO were generally low for the homes studied, the need to properly design storage locations for pellets is and will remain a necessary component of wood pellet heating systems to minimize the risk of CO exposure.
Implications: This paper is an assessment of carbon monoxide (CO) exposure from bulk wood pellet storage in homes in New Hampshire and Massachusetts. Understanding the CO concentrations in homes allows for better designs for storage bins and ventilation for storage areas. Hence, uniform policies for stored wood pellets in homes, schools, and businesses can be framed to ensure occupant safety. Currently in New York State rebates for the installation of wood pellet boilers are only provided if the bulk pellet storage is outside of the home, yet states such as New Hampshire, Vermont, and Maine currently do not have these restrictions. 相似文献
Poly(vinyl alcohol) (PVA) hydrogels were chemically cross-linked with/without different cross-linkers such as glutaraldehyde
and epichlorohydrin, in the presence of a catalyst, or activator (potassium hydroxide) to produce three types of hydrogels.
The structures of PVA and the prepared gel types were determined by FTIR spectroscopy, the mechanical and thermal properties,
of these hydrogels were examined. The effects of different pH values and temperatures on the swelling properties of the prepared
gels were examined. From the obtained results, it was found that, the low concentration of the cross-linker produced hydrogel
with moderate properties, but in absence of the cross-linker, the obtained hydrogel exhibited good properties and can be used
as friendly environmentally moisture absorbents from the organic solvents. The insolubility and swelling properties of gels
were tested in these solvents. The results indicated that these hydrogels can be used as moisture absorbents and solvent dryers. 相似文献
It is commonly assumed that atmospheric oxidation of hydrocarbon particles or hydrocarbon coatings on particles leads to polar products and increased water uptake, altering atmospheric visibility and increasing the likelihood they will act as cloud condensation nuclei (CCN). We show here through laboratory experiments that increased water uptake depends on the 3-dimensional structure of the particles. Laboratory studies of particles formed during ozonolysis of surface-bound alkenes, present as terminally unsaturated self-assembled monolayers (C8= SAM) on a silica substrate, were carried out at room temperature and 1 atm pressure. SAMs were exposed to ~1013 O3 molecules cm?3 for 40 min and resultant particles were analyzed using single particle Fourier transform infrared micro-spectroscopy (micro-FTIR) and secondary ion mass spectroscopy (SIMS). Spectroscopy results show that –COOH and other polar groups are formed but are buried inside a hydrophobic shell, consistent with earlier observations (McIntire et al., 2005, Moussa et al., 2009) that water uptake does not increase after reaction of the terminal alkene with O3. These insights into the 3-D structure of particles formed on oxidation have important implications for the ability of secondary organic aerosols to act as CCN. In addition, the nature of the surface of the particles is expected to determine their uptake into biological systems such as the surface of the lungs. 相似文献
Reactive oxygen species (ROS) and related free radicals are considered to be key factors underpinning the various adverse health effects associated with exposure to ambient particulate matter. Therefore, measurement of ROS is a crucial factor for assessing the potential toxicity of particles. In this work, a novel profluorescent nitroxide, BPEAnit, was investigated as a probe for detecting particle-derived ROS. BPEAnit has a very low fluorescence emission due to inherent quenching by the nitroxide group, but upon radical trapping or redox activity, a strong fluorescence is observed. BPEAnit was tested for detection of ROS present in mainstream and sidestream cigarette smoke. In the case of mainstream cigarette smoke, there was a linear increase in fluorescence intensity with an increasing number of cigarette puffs, equivalent to an average of 101 nmol ROS per cigarette based on the number of moles of the probe reacted. Sidestream cigarette smoke sampled from an environmental chamber exposed BPEAnit to much lower concentrations of particles, but still resulted in a clearly detectible increase in fluorescence intensity with sampling time. It was calculated that the amount of ROS was equivalent to 50 ± 2 nmol per mg of particulate matter; however, this value decreased with ageing of the particles in the chamber. Overall, BPEAnit was shown to provide a sensitive response related to the oxidative capacity of the particulate matter. These findings present a good basis for employing the new BPEAnit probe for the investigation of particle-related ROS generated from cigarette smoke as well as from other combustion sources. 相似文献
One strategy to combat nitrate (NO3-N) contamination in rivers is to understand its sources. NO3-N sources in the East Tiaoxi River of the Yangtze Delta Region were investigated by applying a 15N–18O dual isotope approach. Water samples were collected from the main channel and from the tributaries. Results show that high total N and NO3-N are present in both the main channel and the major tributaries, and NO3-N was one of the most important N forms in water. Analysis of isotopic compositions (δ18O, δD) of water suggests that the river water mainly originated from three tributaries during the sampling period. There was a wide range of δ15N-NO3 (?1.4 to 12.4 ‰) and a narrow range of δ18O-NO3 (3.7 to 9.0 ‰) in the main channel waters. The δ15N and δ18O-NO3 values in the upper, middle, and lower channels along the river were shifted as 8.2, 3.5, and 9.5 ‰, and 9.0, 4.2, and 6.0 ‰, respectively. In the tributary South Tiao, the δ15N and δ18O-NO3 values were as high as 9.5 and 7.0 ‰, while in the tributaries Mid Tiao and North Tiao, NO3-N in most of the samples had relatively low δ15N and δ18O-NO3 values from 2.3 to 7.5 ‰ and 4.7 to 7.0 ‰, separately. Our results also suggest that the dual isotope approach can help us develop the best management practice for relieving NO3-N pollution in the rivers at the tributary scale. 相似文献