Plants constitute a major element of constructed wetlands(CWs).In this study,a coupled system comprising an integrated vertical flow CW(IVCW) and a microbial fuel cell(MFC) for swine wastewater tre atment was developed to research the effects of macrophytes commonly employed in CWs,Canna indica,Acorus calamus,and Ipomoea aquatica,on decontamination and electricity production in the system.Because of the different root types and amounts of oxygen released by the roots,the rates of chemical oxygen demand(COD) and ammonium nitrogen(NH_4~+-N) removal from the swine wastewater differed as well.In the unplanted,Canna indica,Acorus calamus,and Ipomoea aquatica systems,the COD removal rates were 80.20%,88.07%,84.70%,and 82.20%,respectively,and the NH_4~+-N removal rates were 49.96%,75.02%,70.25%,and 68.47%,respectively.The decontamination capability of the Canna indica system was better than those of the other systems.The average output voltages were 520±42,715±20,660±27,and 752±26 mV for the unplanted,Canna indica,Acorus calamus,and Ipomoea aquatica systems,respectively,and the maximum power densities were 0.2230,0.4136,0.3614,and0.4964 W/m~3,respectively.Ipomoea aquatica had the largest effect on bioelectricity generation promotion.In addition,electrochemically active bacteria,Geobacter and Desulfuromonas,were detected in the anodic biofilm by high-throughput sequencing analysis,and Comamonas(Proteobacteria),which is widely found in MFCs,was also detected in the anodic biofilm.These results confirmed the important role of plants in IVCW-MFCs. 相似文献
Changes in water quality from source water to finished water and tap water at two conventional drinking water treatment plants(DWTPs) were monitored.Beside the routine water quality testing,Caenorhabditis elegans-based toxicity assays and the fluorescence excitation–emission matrices technique were also applied.Both DWTPs supplied drinking water that met government standards.Under current test conditions,both the investigated finished water and tap water samples exhibited stronger lethal,genotoxic and reprotoxic potential than the relative source water sample,and the tap water sample was more lethal but tended to be less genotoxic than the corresponding finished water sample.Meanwhile,the nearly complete removal of tryptophan-like substances and newly generated tyrosine-like substances were observed after the treatment of drinking water,and humic-like substances were identified in the tap water.Based on these findings,toxic pollutants,including genotoxic/reproductive toxicants,are produced in the drinking water treatment and/or distribution processes.Moreover,further studies are needed to clarify the potentially important roles of tyrosine-like and humic-like substances in mediating drinking water toxicity and to identify the potential sources of these contaminants.Additionally,tryptophan-like fluorescence may be adopted as a useful parameter to monitor the treatment performance of DWTPs.Our observations provided insights into the importance of utilizing biotoxicity assays and fluorescence spectroscopy as tools to complement the routine evaluation of drinking water. 相似文献
This study explored the national hydrogen refueling infrastructure requirement along major United States (US) interstate highway corridors to support the deployment of fuel cell electric trucks (FCETs) for the national long-haul trucking fleet. Given the long-haul trucking shipment demand in 2025 projected by the Freight Analysis Framework, locations and capacities of hydrogen stations were identified for inter-zone freight flows, and the total daily refueling demand was estimated for intra-zone flows for each FAF zone. Based on the infrastructure deployment results, we conducted an economic feasibility analysis of FCETs by evaluating the total ownership cost. We found that when the FCET penetration is relatively high (e.g., 10% penetration), FCETs become more competitive in terms of fuel cost and idling cost and could be economic viable if the incremental vehicle cost is reduced to meet the near-term FCET technology cost targets and the liquefaction cost is reduced to an optimal case. We also observed that the station cost depends on regional factors, particularly regional demand, which is used to determine station capacity. Thus, one possible strategy for station roll-out is to have early investment in target regions where station costs are expected to be relatively low such as the Pacific and West South Central regions.
Copper-exchanged chabazite (Cu/CHA) catalysts have been found to be affected by alkali metal and alkaline earth ions. However, the effects of Na+ ions on Cu/SAPO-34 for ammonia selective catalytic reduction (NH3-SCR) are still unclear. In order to investigate the mechanism, five samples with various Na contents were synthesized and characterized. It was observed that the introduced Na+ ion-exchanges with H+ and Cu2 + of Cu/SAPO-34. The exchange of H+ is easier than that of isolated Cu2 +. The exchanged Cu2 + ions aggregate and form “CuAl2O4-like” species. The NH3-SCR activity of Cu/SAPO-34 decreases with increasing Na content, and the loss of isolated Cu2 + and acid sites is responsible for the activity loss. 相似文献
Recently, the New Morris Method has been presented as an effective sensitivity analysis tool for mathematical models. The
New Morris Method estimates the sensitivity of an output parameter to a given set of input parameters (first-order effects)
and the extent these parameters interact with each other (second-order effects). This method requires the specification of
two parameters (runs and resolution) that control the sampling of the output parameter to determine its sensitivity to various
inputs. The criteria for these parameters have been set on the analysis of a well-behaved analytical function (see Cropp and
Braddock, Reliab. Eng. Syst. Saf. 78:77–83, 2002), which may not be applicable to other physical models that describe complex
processes. This paper will investigate the appropriateness of the criteria from (Cropp and Braddock, 2002) and hence the effectiveness
of the New Morris Method to determine the sensitivity behaviour of two hydrologic models: the Soil Erosion and Deposition
System and Griffith University Representation of Urban Hydrology. In the first case, this paper will separately analyse the
sensitivity of an output parameter on a set of input parameters (first- and second-order effects) for each model and discuss
the physical meaning of these sensitivities. This will be followed by an investigation into the sampling criteria by exploring
the convergence of the sensitivity behaviour for each model as the sampling of the parameter space is increased. By comparing
these trends to the convergence behaviour from Cropp and Braddock (2002), we will determine how well the New Morris Method
estimates the sensitivity for each model and whether the sampling criteria are appropriate for these models. It will be shown
that the New Morris Method can provide additional insight into the functioning of these models, and that, under a different
metric, the sensitivity behaviour of these models does converge confirming the sampling criteria set by Cropp and Braddock. 相似文献