全文获取类型
收费全文 | 89篇 |
免费 | 1篇 |
国内免费 | 4篇 |
专业分类
安全科学 | 5篇 |
废物处理 | 7篇 |
环保管理 | 9篇 |
综合类 | 10篇 |
基础理论 | 14篇 |
污染及防治 | 28篇 |
评价与监测 | 10篇 |
社会与环境 | 9篇 |
灾害及防治 | 2篇 |
出版年
2023年 | 5篇 |
2022年 | 8篇 |
2021年 | 5篇 |
2020年 | 1篇 |
2019年 | 1篇 |
2018年 | 2篇 |
2017年 | 4篇 |
2016年 | 3篇 |
2015年 | 6篇 |
2014年 | 2篇 |
2013年 | 17篇 |
2012年 | 6篇 |
2011年 | 4篇 |
2010年 | 4篇 |
2009年 | 4篇 |
2008年 | 5篇 |
2007年 | 3篇 |
2006年 | 3篇 |
2005年 | 1篇 |
2004年 | 4篇 |
2003年 | 1篇 |
2002年 | 1篇 |
1998年 | 1篇 |
1992年 | 1篇 |
1981年 | 1篇 |
1976年 | 1篇 |
排序方式: 共有94条查询结果,搜索用时 0 毫秒
91.
Megat Hanafiah Megat Ahmad Kamal Wan Mat Khalir Wan Khaima Azir MohamedKasmawati Zakaria Haslizaidi Wan Ngah Wan Saime 《环境科学学报(英文版)》2010,22(2):248-256
Rubber leaf powder (an agricultural waste) was treated with potassium permanganate followed by sodium carbonate and its
performance in the removal of Pb(II) ions from aqueous solution was evaluated. The interactions between Pb(II) ions and functional
groups on the adsorbent surface were confirmed by Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy
(SEM) coupled with X-ray energy dispersive spectroscopy (EDX). The effects of several important parameters which can affect
adsorption capacity such as pH, adsorbent dosage, initial lead concentration and contact time were studied. The optimum pH range
for lead adsorption was 4–5. Even at very low adsorbent dosage of 0.02 g, almost 100% of Pb(II) ions (23 mg/L) could be removed.
The adsorption capacity was also dependent on lead concentration and contact time, and relatively a short period of time (60–90
min) was required to reach equilibrium. The equilibrium data were analyzed with Langmuir, Freundlich and Dubinin-Radushkevich
isotherms. Based on Langmuir model, the maximum adsorption capacity of lead was 95.3 mg/g. Three kinetic models including pseudo
first-order, pseudo second-order and Boyd were used to analyze the lead adsorption process, and the results showed that the pseudo
second-order fitted well with correlation coefficients greater than 0.99. 相似文献
92.
Kamal A. Rashid John G. Babish Ralph O. Mumma 《Journal of environmental science and health. Part. B》2013,48(8-9):689-701
Abstract Hepatic S9 preparations from Aroclor 1254 induced rats and 3‐methylcholanthrene induced woodchucks were used to investigate, in vitro, the mutagenic potential of five amino acid conjugates of 2, 4‐Dichlorophenoxyacetic acid (alanine, aspartic acid, leucine, methionine and tryptophan). Five strains of Salmonella typhimurium (TA97, TA98, TA100, TA1535, TA1538) were utilized for this purpose. Dose‐response effects producing a two‐fold increase of revertants over spontaneous levels were not observed with either S9 preparation indicating that the amino acid conjugates are not promutagens in these assays. 相似文献
93.
Rakesh Kumar Mahajan Ajar Kamal Naresh Kumar Vandana Bhalla Manoj Kumar 《Environmental science and pollution research international》2013,20(5):3086-3097
The construction and electrodes characteristics of poly(vinylchloride) (PVC)-based polymeric membrane electrode (PME) and coated graphite electrode (CGE), incorporating 1,3-alternate thiacalix[4]crown as ionophore for estimation of Hg(II) ions, are reported here. The best potential response was observed for PME-1 having membrane composition of: ionophore (6.2 mg), PVC (100.0 mg), 2-nitrophenyl octyl ether (2-NPOE; 200.0 mg), and sodium tetraphenyl borate (NaTPB; 2.0 mg); for CGE-1 with the membrane composition: ionophore (3.5 mg), PVC (40.0 mg), 2-NPOE (80.0 mg), and NaTPB (2.0 mg). The electrodes exhibits Nernstian slope of 29.16 mV/decade with PME-1 and 30.39 mV/decade with CGE-1 for Hg(II) ions over wide concentration range, i.e., 1.0?×?10?1 to 5.0?×?10?6?M with PME-1 and 1.0?×?10?1 to 5.0?×?10?7?M with CGE-1. Lower detection limits were found to be 9.77?×?10?6?M for PME-1 and 7.76?×?10?7?M for CGE-1 with response time varying from 10 to 20 s. Also, these electrodes work within pH range of 2.0–6.0 for PME-1 and 1.5–6.5 for CGE-1. Overall, CGE-1 has been found to be better than PME-1. CGE-1 has been used as indicator electrode for the potentiometric titration of Hg(II) ions with EDTA as well as successfully applied for determination of Hg(II) content in wastewater, insecticide, dental amalgam, and ayurvedic medicines samples with very good performance (0.9974 correlation coefficient in the comparison against volumetric method). 相似文献
94.