首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   173篇
  免费   4篇
  国内免费   12篇
安全科学   11篇
废物处理   12篇
环保管理   17篇
综合类   26篇
基础理论   29篇
环境理论   1篇
污染及防治   77篇
评价与监测   9篇
社会与环境   4篇
灾害及防治   3篇
  2023年   1篇
  2022年   2篇
  2019年   1篇
  2018年   7篇
  2017年   12篇
  2016年   7篇
  2015年   7篇
  2014年   8篇
  2013年   19篇
  2012年   12篇
  2011年   13篇
  2010年   12篇
  2009年   9篇
  2008年   18篇
  2007年   16篇
  2006年   10篇
  2005年   10篇
  2004年   10篇
  2003年   6篇
  2002年   3篇
  2001年   1篇
  1994年   1篇
  1991年   1篇
  1978年   1篇
  1970年   1篇
  1969年   1篇
排序方式: 共有189条查询结果,搜索用时 93 毫秒
71.
The present study was conducted to determine the residue levels of persistent organochlorines such as PCB homologues, DDT and its metabolites, and HCH isomers in the ventral blubber of female northern fur seal (Callorhinus ursinus) collected off Sanriku, the Pacific coast of northern Japan, since 1971. Among the organochlorines examined, the concentrations of PCBs and DDTs were found to be high in all samples. The residue levels of these two contaminants showed a drastic reduction following maturity and then a slight increase after the retirement from pregnancy/menopause. Temporal variation of PCB and DDT residues showed maximum levels around 1976 and then decreased, whereas HCH residue levels revealed a very slow declining pattern. Considering the concentrations and compositions of the residues, the northern fur seal is likely to be exposed to organochlorine contamination deriving from global terms. In this context, continuous contamination has been foreseen with regard to PCB and HCH residues. The pattern of organochlorine residues indicated that the northern fur seal has higher metabolic capacity than Dall's porpoise, while it is comparable to those of larga seal and Steller sea lion.  相似文献   
72.
The behavior of particulate matter (PM) during high-concentration episodes was investigated using monitoring data from Guui station, a comprehensive air monitoring station in Seoul, Korea, from January 2008 to March 2010. Five non-Asian dust (ND) episodes and two Asian dust (AD) episodes of high PM concentrations were selected for the study. During the ND episode, primary air pollutants accumulated due to low wind speeds, and PM2.5 increased along with most other air pollutants. Particles larger than PM2.5 were also high since these particles were generated by vehicular traffic rather than wind erosion. During strong AD episodes, PM10–2.5 primarily increased and gaseous primary air pollutants decreased under high wind speeds. However, even during the AD episode, PM2.5 and gaseous primary air pollutants increased when the effects of AD were weak and wind speeds were low. This study corroborates that accumulation of air pollutants due to a drop in surface wind speed plays an important role in short-term high-concentration occurrences. However, low wind speeds could not be directly linked to local emissions because a significant portion of accumulated air pollutants resulted from long-range transport.  相似文献   
73.
74.
75.
A numerical model, the Curvilinear Hydrodynamics in 3‐Dimensions, Waterway Experiment Station version (CH3D‐WES), was applied to represent transport processes of the Chesapeake Bay. Grid resolution and spatial coverage, tied with realistic bathymetry, ensured dynamic responses along the channel and near the shoreline. The model was run with the forcing ranges from high frequency astronomical tides to lower frequency meteorological forcing, given by surface wind and heat flux, as well as hydrological forcing given by fresh water inflows both from upstream and distributed sources along the shoreline. To validate the model, a long‐term simulation over seven‐year time period between 1994 and 2000 was performed. The model results were compared with existing observation data including water level time series, which spans over a wide spectrum of time scales, and long‐term variations in salinity structures over varying parts of the Bay. The validated model is set to provide an appropriate transport mechanism to the water quality model through linkage, warranting that the model takes into account the complexity in time and spatial scales associated with the dynamic processes in the Chesapeake.  相似文献   
76.
To evaluate the effect of handle design characteristics on subjective ratings and pulling forces, meat-hook handles with various handle shapes, sizes, and hook positions were tested in a pulling task. Finger and phalange force data measured by force sensitive resistors and subjective ratings of discomfort were also evaluated. Generally subjects preferred 37-mm double frustum, 30-mm oval handles followed by 30-mm double frustum handles, 37-mm oval, and 45-mm double frustum handles. In the analyses of total pulling force, 37- and 45-mm double frustum handles showed less required pulling force than the others. The averages of finger force contributions to the total pulling force were 27.2, 28.1, 23.9, and 20.8% in order from index to little fingers. The average of phalange force contributions were 28.8, 33.6, and 37.6% for the distal, middle, and proximal phalanges, respectively. The findings illustrate that the pulling finger forces and subjective discomfort ratings were related to the handle shape as well as handle size.  相似文献   
77.
A systematic modeling approach to describing, prescribing, and predicting usability of a product has been presented. Given the evaluation results of the usability dimension (UD) and the measurement of the product’s design variables, referred to as the human interface elements (HIEs), the approach enables one to systematically assess the relationship between the UD and HIEs. The assessed relationship is called a usability model. Once built, such a usability model can relate, in a quantitative manner, the HIEs directly to the UDs, and thus can serve as an effective aid to designers by evaluating and predicting the usability of an existing or hypothetical product. A usability model for elegance of audiovisual consumer electronic products has been demonstrated.  相似文献   
78.
79.
Live algae carrying hydrophobic xenobiotics can be an effective vector candidate for the chemical translocation to filter feeders in the laboratory toxicity test, but information on their application is lacking. Time-course uptake and elimination of polychlorinated biphenyls (PCBs) (0, 50, 100, and 500 ng g(-1) by two key algal foods, Isochrysis galbana and Tetraselmis suecica, were measured. Both of the algae achieved maximum concentration in an hourafter PCBs exposure regardless the chemical concentrations in our time-course measurements (0, 1, 5, 10, 24, 48 and 72 hrs). Once achieved the maximum concentration, the algae shortly exhibited elimination or eliminating tendency depending on the chemical concentrations. Algae exposed to the chemical for 1 and 24 hrs (hereafter 1 and 24 hr vectors, respectively) were then evaluated as a chemical translocation vector by feeding test to larval and spat Crassostrea gigas. In the feeding test the 24 hr vector, which contained lower chemicals than the 1-hr vector, appeared to be more damaging the early lives of the oyster. This was particularly significant for vectors of higher PCBs (p<0.05), probably due to algal reduction in food value by the prolonged chemical stress. These findings imply that 1 hr exposure is long enough for a generation of algal vector for laboratory toxicity test, minimizing data error resulted from reduction in food value by longer chemical stress.  相似文献   
80.
Elemental mercury(Hg0) is predominant constituent of flue gas emitted from coal-fired power plants. Adsorption has been considered the best available technology for removal of Hg0 from flue gas. However, adsorbent injection increases the amount of ash generated. In the present study, powdered activated carbon(PAC) was coated on polytetrafluoroethylene/glass fiber filters to increase Hg0 removal while concurrently reducing the amount of ash generated. The optimal PAC coating rate was determined in laboratory experiments to ensure better Hg0 removal with low pressure drop. When PAC of particle size less than 45 μm was used, and the areal density was 50 g/m2, the pressure drop remained under 30 Pa while the Hg0 removal efficiency increased to 15.8% from4.3%. The Hg0 removal efficiency also increased with decrease in filtration velocity. The optimal PAC coating rate was applied on a hybrid filter(HF), which was combined with a bag filter and an electrostatic precipitator in a single chamber. Originally designed to remove fine particulates matter, it was retrofitted to the flue gas control device for simultaneous Hg0 removal. By employing the PAC coating, the Hg removal efficiency of the HF increased to 79.79% from 66.35%. Also, a temporary reduction in Hg removal was seen but this was resolved following a cleaning cycle in which the dust layer was removed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号