首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   81篇
  免费   0篇
  国内免费   3篇
废物处理   11篇
环保管理   3篇
综合类   12篇
基础理论   14篇
污染及防治   35篇
评价与监测   7篇
社会与环境   2篇
  2021年   2篇
  2018年   3篇
  2017年   1篇
  2015年   1篇
  2014年   4篇
  2013年   9篇
  2012年   4篇
  2011年   11篇
  2009年   5篇
  2008年   5篇
  2007年   10篇
  2006年   2篇
  2005年   4篇
  2004年   4篇
  2003年   4篇
  2002年   2篇
  1999年   1篇
  1998年   2篇
  1997年   1篇
  1993年   2篇
  1983年   2篇
  1978年   1篇
  1974年   1篇
  1972年   1篇
  1968年   1篇
  1964年   1篇
排序方式: 共有84条查询结果,搜索用时 15 毫秒
51.
52.
In our previous work, the primary sludge from wastewater treatment plants was shown to contain a considerable amount of cellulose (about 20%, based on suspended solids) owing to the discharge of toilet paper. For the purpose of using the cellulose as a biomass resource, this study examined a simple method for its recovery. When fibrous cellulose was suspended in 0.3% sulfuric acid and autoclaved at 130°C for 60 min, 85%–88% of the initial solids remained without dissolving. Under these conditions, an activated sludge sample not containing cellulose was strongly hydrolyzed and only 7% of the initial solids remained. The prescribed amounts of cellulose added to the activated sludge sample were quantitatively recovered by the autoclaving treatment. In the treatment of primary sludge containing >20% cellulose, residual solids with relatively high levels of cellulose (>69%) could be obtained. The results indicate that the method proposed here could recover cellulose practically from waste sewage sludge for biomass utilization. Received: July 17, 2000 / Accepted: July 4, 2001  相似文献   
53.
The characteristics of municipal wastewater treatment by electrolysis, ozonation, and combination processes of electrolysis and aeration using three gaseous species (nitrogen [N2], oxygen [O2], and ozone [O3]) were discussed in this research using ruthenium oxide (RuO2)-coated titanium anodes and stainless-steel (SUS304) cathodes. Electrolysis and electrolysis with nitrogen aeration were characterized by a rapid decrease in 5-day biochemical oxygen demand (BODs) and total nitrogen and a slow decrease in chemical oxygen demand (COD). In contrast, ozonation, electrolysis with oxygen aeration, and electrolysis with ozone aeration were characterized by transformation of persistent organic matter to biodegradable matter and preservation of total nitrogen. The best energy efficiency in removing BOD5 and total nitrogen was demonstrated by electrolysis, as a result of direct anodic oxidation and indirect oxidation with free chlorine produced from the chloride ion (Cl-) at the anodes. However, electrolysis with ozone aeration was found to be superior to the other processes, in terms of its energy efficiency in removing COD and its ability to remove COD completely, as a result of hydroxyl radical (*OH) production via cathodic reduction of ozone.  相似文献   
54.
55.
Certain enteric viruses that are present in the water environment are potential risk factors of waterborne infections. To better understand the impact of viruses in water, both enteric viruses and their potential indicators should be comparatively investigated. In this study, occurrences of GI- and GII-noroviruses (NoVs), sapovirus (SaV), rotavirus (RoV), Aichi virus 1 (AiV-1), enterovirus (EV), and pepper mild mottle virus (PMMoV) were quantitatively determined in surface water samples in Japan. Additionally, the genotype distribution of GI- and GII-NoVs was determined using a next-generation amplicon sequencing. PMMoV was the most abundant virus regardless of season and location, indicating its usefulness as an indicator for the viral contamination of water. Other potential indicators, AiV and EV, were less abundant than GII-NoV. Viruses other than PMMoV showed seasonality, i.e., EV and other viruses (NoVs, SaV, RoV, and AiV-1) became prevalent during summer and winter, respectively. SaV showed a relatively high abundance at a location that was affected by untreated wastewater. Regarding NoV genotypes, GI.1, GI.2, GI.4, GI.5, GI.6, GII.3, GII.4, GII.6, and GII.17 were found from the surface water samples. GII.4 and GII.17 seemed to have contributed to the high abundance of GII-NoV in the samples. Interestingly, GII.17 strains became prevalent in the water samples before becoming prevalent among gastroenteritis patients in Japan. These findings provide further insights into the properties of viruses as contaminants in the water environment.  相似文献   
56.
A voltammetric determination of possible organic pollutants such as diol and phenolic compounds in water was studied using ferroceneboronic acid (FBA) as a redox-active marker. A cyclic voltammogram of FBA exhibited a pair of oxidation and reduction peaks at 230 and 170 mV at pH 7.0, respectively, while another pair of redox peaks was observed in the presence of diol or phenolic compounds tested. The results were rationalized based on the formation of boronate esters of FBA with the added compounds. The changes in the redox peak currents were dependent on the concentration of the additives, suggesting a usefulness of FBA in the electrochemical determination of these compounds in water.  相似文献   
57.
Urea decomposes to ammonia and carbon dioxide via carbamic acid, and amine groups can be introduced to the glassy carbon electrode surface during the electrode oxidation of carbamic acid. This modified carbon electrode has excellent catalytic activity of the oxidation of carbamic acid, and can be used to electrooxidize urea by combining urease reaction and electrode oxidation. We found that nitrogen gas is finally produced by the carbamic acid produced from urea. The production of nitrogen was confirmed by gas chromatography-mass spectrometry, and fragment pattern of hydrazine was also detected in the electrolyzed solution of urea. We intend to describe new electrochemical conversion system of urea to harmless nitrogen gas. The electrode oxidation current of urea was decreased by addition of radical trapping agent such as DMPO (5,5-dimethyl-1-pyrroline N-oxide), and this fact suggests that carbamic acid radical couples to form nitrogen-nitrogen bond, and this dimer is oxidized to nitrogen. The electrode oxidation current of urea became larger when oxygen was removed. This fact indicates that the intermediate species (probably hydrazine) produced by the electrolysis is oxidized by not only electrode reaction but also oxygen.  相似文献   
58.
Residue levels of organochlorine pesticides (DDTs, HCHs, HCB and chlordane compounds) were determined in core samples collected from Nile River near by Cairo and Manzala Lake, Egypt in 1994. Regional difference and vertical profiles were discussed in view of historical reconstruction of environmental pollution by these chemicals. On the basis of estimated sedimentation rate (0.5 to 0.7 cm/year) in Manzala Lake, it seems that discharge of DDTs and CHLs into Egyptian environment increased rapidly from early 1960's and the maximum discharge was recorded in 1980's. However, concentration of HCHs increased continuously up to the present in spite of decreasing of DDTs and CHLs after 1980's. It was revealed that vertical profiles of organochlorine pesticides in sediment core from Manzala Lake are useful to estimate a temporal trend of pesticide use in Egypt.  相似文献   
59.
The aim of the present study was to show a relationship between toxicity of 100-fold concentrated water and aquatic habitat conditions. Environmental waters are 100-fold concentrated with solid-phase extraction. Medaka early fry was exposed in these waters for 48 h. The number of death and disorder was counted at 1, 2, 3, 6, 12, 24, and 48 h; toxicity was expressed using inverse median effect time and median lethal time (ET (50)(-1), LT (50)(-1)). Average score per taxon (ASPT) for benthic animals and Index of Biotic Integrity (IBI) for fish were applied as indices of aquatic habitat conditions. The results of toxicity test were compared using ASPT and IBI. The different levels of toxicity were detected in the seawater of Japan. At the Husino River area, toxicity cannot be detected. In rivers, high toxicity appeared at urban districts without sewerage. By Spearman coefficient, the relationship between toxicity and high biochemical oxygen demand (BOD) were obtained. BOD household wastewater contains hydrophobic toxic matters; otherwise, seawater in industrial area does not show clear relationship between toxicity and chemical oxygen demand. Gas chromatography to mass spectrometry simultaneous analysis database may give an answer for the source of toxicity, but further test is required. Ratio of clear stream benthic animal sharply decreased over 0.25 of LT (50)(-1) or 0.5 of ET (50)(-1). Tolerant fish becomes dominant over 0.3 of LT (50)(-1) or 0.5-1.0 of ET (50)(-1). By Pearson product-moment correlation coefficient, correlation coefficient between toxicity and ASPT was obtained at -0.773 (ET (50)(-1)) and -0.742 (LT (50)(-1)) at 1 % level of significance with a high negative correlation. Toxicity (LT (50)(-1) ) has strong correlation with the ratio of tolerant species. By Pearson product-moment correlation coefficient, correlation coefficient between toxicity and IBI obtained were -0.155 (ET (50)(-1)) and -0.190 (LT (50)(-1)) at 1 % level of significance and has a low or no correlation between toxicity and IBI. Even with low toxic environmental waters, toxicity test using 100-fold concentrated and medaka early fly could detect acute toxicity. The detected toxicity seemed to limit the inhabiting aquatic species in the water body.  相似文献   
60.
The occurrence of free and conjugated estrogens was examined in a survey of eleven sewage treatment plants (STPs) and their discharge water in the United Kingdom using grab sampling. The STPs included trickling filter with and without tertiary treatment, and activated sludge with tertiary treatment. For three activated sludge plants both influent and effluent samples were compared. For a further 8 STPs only the effluent was examined. The estrone-3-sulphate, estradiol-3-sulphate and estriol-3-sulphate concentrations (up to 20 ng L−1) were typically 5-fold that of the respective free estrogen concentration in the effluents. This represents a substantial additional ‘potential’ estrogen load arriving in the receiving waters. Estrone-3-glucuronide was found at 9 ng L−1, estradiol-3-glucuronide at 7 ng L−1, and estriol-3-glucuronide at 32 ng L−1 in sewage influent. Except on one occasion, no glucuronide conjugates could be found in the effluent. The results suggest in most cases glucuronide conjugates will be completely transformed in sewage treatment whilst sulphate conjugates will only be partially removed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号