全文获取类型
收费全文 | 163篇 |
免费 | 1篇 |
国内免费 | 19篇 |
专业分类
安全科学 | 30篇 |
废物处理 | 10篇 |
环保管理 | 12篇 |
综合类 | 33篇 |
基础理论 | 20篇 |
污染及防治 | 49篇 |
评价与监测 | 15篇 |
社会与环境 | 12篇 |
灾害及防治 | 2篇 |
出版年
2023年 | 3篇 |
2022年 | 9篇 |
2021年 | 6篇 |
2020年 | 1篇 |
2019年 | 7篇 |
2018年 | 2篇 |
2017年 | 4篇 |
2016年 | 12篇 |
2015年 | 10篇 |
2014年 | 5篇 |
2013年 | 13篇 |
2012年 | 10篇 |
2011年 | 4篇 |
2010年 | 10篇 |
2009年 | 14篇 |
2008年 | 10篇 |
2007年 | 6篇 |
2006年 | 10篇 |
2005年 | 5篇 |
2004年 | 4篇 |
2003年 | 10篇 |
2002年 | 5篇 |
2001年 | 4篇 |
2000年 | 1篇 |
1999年 | 2篇 |
1998年 | 1篇 |
1997年 | 3篇 |
1996年 | 1篇 |
1994年 | 1篇 |
1992年 | 2篇 |
1991年 | 1篇 |
1989年 | 1篇 |
1986年 | 1篇 |
1983年 | 1篇 |
1982年 | 1篇 |
1981年 | 1篇 |
1980年 | 1篇 |
1979年 | 1篇 |
排序方式: 共有183条查询结果,搜索用时 15 毫秒
151.
It is widely purported that urban parks and open spaces can improve the urban environment by cleansing the air and reducing
the noise. However, such environmental functions can be constrained by the size and the location of urban parks in very dense
cities. This study examines the air and acoustic environment and heavy metal contamination in Hong Kong urban parks and open
spaces. Using a hybrid field measurement and computer simulation approach, the study has found that while the air quality
in urban parks is better than that of the roadside, it is not significantly different from that of the ambient conditions.
Noise levels in the urban parks are not significantly lower than those at the typical home environment in Hong Kong. Heavy
metals in urban park dust are slightly lower than that found at the roadside and are broadly comparable to those found at
typical homes and nursery schools. These findings lend support to the postulation that the capability of urban parks and open
spaces in dense cities to improve the urban environment is rather limited and call for a re-examination of the role of urban
parks in enhancing urban livability. The findings also have implications on how urban parks in dense cities should be designed
and managed. 相似文献
152.
Endocrine disruptor contamination is an emerging issue of concern in the field of water quality engineering. In this study, a lab-scale microfiltration (MF) and reverse osmosis (RO) based water reclamation system was set up to monitor and evaluate the removal of bisphenol A (BPA), which is a known oestrogenic compound. The identification and quantification of BPA were performed by using gas chromatography coupled with mass spectrometry. It was noted that the detection method used in this study was able to achieve an average recovery ranging from 88.2 to 94.1% of BPA with standard deviations of less than 10% in different spiked samples. The detection limit of the analytical protocol was determined at 20 ng L(-1). Based on the analytical protocol, it was noted that a low level of BPA (1.18-3.04 microg L(-1)) could be detected in feed water (effluent of an activated sludge treatment system) to the dual membrane water reclamation system. The results obtained suggested that BPA could be easily chlorinated by sodium hypochlorite with a dosage of 4 to 5 mg L(-1) and a contact time of 1 to 2 min. In this lab-scale study, a satisfactory removal of BPA was readily obtained by RO and BPA was abated to an undetectable level in the product water. It was noted that the RO rejection characteristic of BPA was not sensitive to the variations in raw feed water characteristics experienced in this study. In addition, it was noted that BPA concentration present in raw feed water did not exert any significant impact on RO performance in terms of BPA rejection. The results of this study demonstrated that membrane technology could be effectively used for BPA removal. 相似文献
153.
Ebrahim Mahmoudi Sepehr Azizkhani Abdul Wahab Mohamma Law Yong Ng Abdelbaki Benamor Wei Lun Ang Muneer Ba-Abbad 《环境科学学报(英文版)》2020,32(12):151-160
Graphene oxide is a very high capacity adsorbent due to its functional groups and π?π interactions with other compounds. Adsorption capacity of graphene oxide, however, can be further enhanced by having synergistic effects through the use of mixed-matrix composite. In this study, silica-decorated graphene oxide (SGO) was used as a high-efficiency adsorbent to remove Congo red (CR) and Cadmium (II) from aqueous solutions. The effects of solution initial concentration (20 to 120 mg/l), solution pH (pH 2 to 7), adsorption duration (0 to 140 min) and temperature (298 to 323 K) were measured in order to optimize the adsorption conditions using the SGO adsorbent. Morphological analysis indicated that the silica nanoparticles could be dispersed uniformly on the graphene oxide surfaces. The maximum capacities of adsorbent for effective removal of Cd (II) and CR were 43.45 and 333.33 mg/g based on Freundlich and Langmuir isotherms, respectively. Langmuir and Freundlich isotherms displayed the highest values of Qmax for CR and Cd (II) adsorption in this study, which indicated monolayer adsorption of CR and multilayer adsorption of Cd (II) onto the SGO, respectively. Thermodynamic study showed that the enthalpy (ΔH) and Gibbs free energy(ΔG) values of the adsorption process for both pollutants were negative, suggesting that the process was spontaneous and exothermic in nature. This study showed active sites of SGO (π-π, hydroxyl, carboxyl, ketone, silane-based functional groups) contributed to an enormous enhancement in simultaneous removal of CR and Cd (II) from an aqueous solution, Therefore, SGO can be considered as a promising adsorbent for future water pollution control and removal of hazardous materials from aqueous solutions. 相似文献
154.
Raymond R. Tan Denny Kok Sum Ng Dominic Chwan Yee Foo 《Journal of Cleaner Production》2009,17(10):940-944
A graphical pinch-based methodology for planning retrofits for carbon capture and storage (CCS) in the power generation sector is presented in this work. CCS is widely seen as one of the essential interim technologies to mitigate greenhouse gas emissions, while still being able to utilize fossil fuels, which are relatively inexpensive and reliable in comparison to inherently low-carbon renewable resources. However, retrofitting power plants for CCS entails major capital costs as well as a reduction of thermal efficiency and power output. Thus, it is essential for planning purposes to implement the minimal extent of CCS retrofit that meets the sectoral carbon footprint targets. At the same time, it is necessary to plan for additional power generation capacity or efficiency enhancements to compensate for energy losses resulting from CCS retrofits. The simple graphical approach used in this paper is designed to determine such targets, and shares the same intuitive, insight-driven characteristics of pinch analysis techniques. A case study is shown to illustrate the methodology. 相似文献
155.
Violet Diacomanolis Barry N. Noller Jack C. Ng 《Environmental geochemistry and health》2013,35(6):757-766
Arsenic (As) and lead (Pb) are common contaminants found in mine waste materials. For an evidence-based risk assessment, it is important to better understand the potential interaction of mixed contaminants; and this interaction study was investigated in an in vivo rat model. Following co-administration of a fixed dose of AsV as in sodium arsenate and different doses of Pb as lead acetate to Sprague–Dawley rats, blood arsenic concentration and bioavailability decreased. A decrease in As blood concentration when lead was co-administered was observed with increasing lead doses. Pharmacokinetic parameters for As in the blood showed faster absorption and elimination of this metalloid in the presence of Pb. The elimination half-life of As decreased from 67 days in As solo group to 27–30 with doses of Pb. Bioavailability of As was also decreased by 30–43 % in the presence of Pb. Decreased urinary excretion of Pb and tissue accumulation were also observed. It indicates lower absorption of As when co-administered with Pb. A probable explanation for these findings is that As co-administration with Pb could have resulted in the formation of less soluble lead arsenate. However, such an interaction between As and Pb could only explain about one-third of the variation when real mine waste materials containing both of these elements were administered to rats. This suggests that other effects from physical and chemical parameters could contribute to the bioavailability of arsenic in complex real environmental samples. 相似文献
156.
Grease traps are widely used by most restaurants and food processing industries in Hong Kong to reduce oil and grease to an acceptable level before it can be discharged to public sewers. To meet demanding effluent standards in the future, it is necessary to polish the effluent by upgrading the conventional trap design. This study evaluated the possibility of upgrading traditional grease traps by installing tube settlers inside the trap. Their efficiency of removing chemical oxygen demand (COD) and oil/grease was examined to justify the performance. It was found that installing a tube settler is a feasible and cheap way to upgrade the conventional grease trap, since it improved oil/grease removal efficiency by 8-10% compared to the conventional design. In addition, a remarkable improvement in COD removal was observed following a very short hydraulic detention time after the installation of tube settlers. This ensured acceptable effluent quality under peak flowrates. Two mathematical models were also proposed to facilitate trap design. 相似文献
157.
We present herein our perspective of a novel Small Habitats Matrix (SHM) concept showing how small habitats on private lands are untapped but can be valuable for mitigating ecological degradation. Grounded by the realities in Sabah, Malaysian Borneo, we model a discontinuous “stepping stones” linkage that includes both terrestrial and aquatic habitats to illustrate exactly how the SHM can be deployed. Taken together, the SHM is expected to optimize the meta-population vitality in monoculture landscapes for aerial, arboreal, terrestrial and aquatic wildlife communities. We also provide the tangible cost estimates and discuss how such a concept is both economically affordable and plausible to complement global conservation initiatives. By proposing a practical approach to conservation in the rapidly developing tropics, we present a perspective from “ground zero” that reaches out to fellow scientists, funders, activists and pro-environmental land owners who often ask, “What more can we do?” 相似文献
158.
Bo Zhang Hoi Dick Ng John H.S. Lee 《Journal of Loss Prevention in the Process Industries》2013,26(6):1293-1299
For the explosion safety assessment in industrial setting, detonation dynamic parameters provide important information on the sensitivity and conditions whereby detonations can be favorably occurred. In this study, new measurement of the critical tube diameter and the critical energy for direct initiation of a detonation is reported for a number of hydrocarbon–oxygen mixtures. The simultaneous experimental measurement carried out in this work allows the investigation of the direct scaling between these two dynamic parameter quantities of gaseous detonations. Using the new set of data, this paper also assesses the validity of an existing semi-empirical initiation model, namely, the surface energy model by Lee, and a simplified work done model. Both phenomenological models provide a general relationship between the two dynamic detonation parameters and comparison shows a good agreement between the theoretical results and the experimental measurement. The scaling of critical tube diameter with detonation cell size in this study also confirms the results in the previous literature. 相似文献
159.
Yu Wang Kelvin Tsun Wai Ng Aklima Zerin Asha 《Journal of Material Cycles and Waste Management》2016,18(4):715-724
The paper presents the results on the analysis of non-hazardous waste generation characteristics and recycling practices in Saskatchewan (SK) and Manitoba (MB) using the biennial waste reports published by Statistic Canada. The objectives are to examine the waste generation rates from both residential and non-residential sources from 1998 to 2010, and to evaluate the effectiveness of their recycling programs and regulations. In spite of the many similarities between the provinces, MB on average generated 17.5 % more residential waste than SK, and about 15 % less non-residential waste than SK during the study period. It appears that MB waste generation characteristics were very different from SK and the rest of Canada. The amount of MSW generation in MB was, to a certain degree, independent from the economic factors. Assuming status quos conditions, the linear models predicted that the per capita MSW generations in MB would be about 33 % lower than SK in 2020. Data from this study suggest that (1) curbside recycling programs and (2) pay-as-you-throw collection systems may be important factors for increasing diversion rate in SK. It is also found that the non-residential waste generation in Canada was substantially larger than the residential waste generation during the 13-year period. 相似文献
160.
This study investigated the degradation and production of volatile fatty acids(VFAs)in the acidogenic phase reactor of a two-phase anaerobic system.20 mmol/L bromoethanesulfonic acid(BESA)was used to inhibit acidogenic methanogens(which were present in the acidogenic phase reactor)from degrading VFAs.The impact of undissociated volatile fatty acids(un VFAs)on"net"VFAs production in the acidogenic phase reactor was then evaluated,with the exclusion of concurrent VFAs degradation."Net"VFAs production from glucose degradation was partially inhibited at high un VFAs concentrations,with 59%,37% and 60% reduction in production rates at 2190 mg chemical oxygen demand(COD)/L undissociated acetic acid(un HAc),2130 mg COD/L undissociated propionic acid(un HPr)and 2280 mg COD/L undissociated n-butyric acid(un HBu),respectively.The profile of VFAs produced further indicated that while an un VFA can primarily affect its own formation,there were also un VFAs that affected the formation of other VFAs. 相似文献