首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   35篇
  免费   0篇
  国内免费   1篇
安全科学   1篇
废物处理   1篇
环保管理   2篇
综合类   8篇
基础理论   3篇
污染及防治   13篇
评价与监测   6篇
社会与环境   2篇
  2014年   1篇
  2013年   4篇
  2012年   1篇
  2011年   2篇
  2010年   2篇
  2007年   4篇
  2006年   1篇
  2005年   3篇
  2003年   2篇
  2002年   1篇
  2001年   1篇
  1995年   1篇
  1994年   1篇
  1993年   1篇
  1990年   1篇
  1988年   1篇
  1984年   1篇
  1965年   1篇
  1964年   1篇
  1963年   1篇
  1959年   1篇
  1958年   1篇
  1954年   1篇
  1944年   1篇
  1913年   1篇
排序方式: 共有36条查询结果,搜索用时 15 毫秒
11.
Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.  相似文献   
12.
13.
Two test methods are presented to assess the cytotoxicity of chemicals. On one hand the protozoonTetrahymena pyriformis and on the other the bacteriumPseudomonas aeruginosa is cultured in defined media containing the test chemicals. Test parameter is the quantity of living cells surviving exposure. The conversion of the tetrazolium salt MTT into formazan is equivalent to cell viability. A mixture of detergent and isopropanol is used to dissolve the blue formazan which is not soluble in water, prior to photometric measurement. For cetyltrimethylammonium bromide, benzyldimethyldodecylammonium chloride, dodecylbenzenesulfonic acid sodium salt, potassium dichromate, 4-toluenesulfonic acid sodium salt, and 4-nitrophenol the EC50-values (mol/l) in theTetrahymena pyriformis- (Pseudomonas aeruginosa) test system were: 10?5,81 (10?5,08); 10?4,68) (10?3,80; 10?4,50 (10?4,14); 10?3,97 (10?5,11); 10?2,71 (10?2,50) and 10?4,00 (10?3,64). — With the assays described here it is possible to measure a large number of samples by quick and simple means.  相似文献   
14.
Controlling fugitive emissions from leaks in petrochemical industry process equipment now requires periodic monitoring of valves, flanges, pumps etc., typically on a quarterly basis. Previous studies have shown that over 90% of the reducible emissions come from approximately 0.1% of the components, i.e. the large leakers. A new, and more cost-effective approach for controlling these large leakers would entail more frequent monitoring of process equipment, allowing for the detection and repair of the highly leaking components that contribute the most to emissions. This approach has been called "Smart LDAR." New optical imaging instruments, which significantly reduce monitoring costs, are now available to implement such an alternative work practice. This work describes the determination of the leak detection sensitivity (equivalency threshold) that an optical imaging instrument must achieve to ensure that it will provide at least the equivalent emission control of the current leak detection and repair practice. Equivalency thresholds were developed for various monitoring intervals. The U.S. Environment Protection Agency's Monte Carlo simulation approach was used to perform the analysis and to demonstrate that optical imaging, which is capable of identifying all of the largest leakers, can provide better control of fugitive emissions.  相似文献   
15.
Hearing protectors attenuate both the background noise and the useful sounds embedded in noise such as the sounds of speech and warning signals. An effective hearing protector is one that attenuates background noise while leaving sufficient energy of speech and warning signals to reach the ear of the worker. At present, however, there are no established criteria for assessing effective change in speech-to-noise ratio caused by hearing protection devices (HPDs). One such criterion could be a change in most comfortable (listening) level (MCL) for speech caused by the presence of HPDs. In this study the HPD-related shift in MCL for speech presented in quiet was measured and compared with two measures of noise attenuation: Noise Reduction Rating (NRR) and high–medium–low (H–M–L). The results indicate that the MCL shift may be a sensitive measure of speech attenuation by HPDs, which together with the appropriate H–M–L may describe technical properties of HPDs.  相似文献   
16.
要获得有意义的温室气体清单,重要的是清单中包括的内容的方法论和定义应该是一致的.国际石油工业环境保护协会(IPIECA)、国际石油和天然气生产者协会(OGP)以及美国石油学会(API)已经制定了温室气体排放计算和报告的准则.国际石油工业环境保护协会(IPITCA)报告温室气体排放的石油工业指南的重点是放在石油工业温室气体排放的计算和报告上.为了提供排放估算一致的方法论,美国石油工业协会制定了石油和天然气工业温室气体排放估算方法论概要.从美国石油学会可以得到一个估算排放的工具--SANGEATM能源和排放估算系统.  相似文献   
17.
18.
19.
The effect of nitrate on the reduction of TCE by commercial granular iron was investigated in column experiments designed to allow for the in situ monitoring of the iron surface film with Raman spectroscopy. Three column experiments were conducted; one with an influent solution of 100 mg/l nitrate+1.5 mg/l TCE, and two control columns, one saturated directly with 100 mg/l nitrate solution, the other pre-treated with Millipore water prior to the introduction of a 100 mg/l nitrate solution. In the presence of nitrate, TCE adsorbed onto the iron, but there was little TCE reduction to end-products ethene and ethane. The iron used (Connelly, GPM, Chicago) is a product typical of those used in permeable granular iron walls. The material is covered by an air-formed high-temperature oxidation film, consisting of an inner layer of Fe(3)O(4), and an outer, passive layer of Fe(2)O(3). In the control column pre-treated with Millipore water, the passive Fe(2)O(3) layer was removed upon contact with the water in a manner consistent with an autoreduction reaction. In the TCE+nitrate column and the direct nitrate saturation column, nitrate interfered with the removal of the passive layer and maintained conditions such that high valency protective corrosion species, including Fe(2)O(3) and FeOOH, were stable at the iron surface. The lack of TCE reduction is explained by the presence of these species, as they inhibit both mechanisms proposed for TCE reduction by iron, including catalytic hydrogenation, and direct electron transfer.  相似文献   
20.
Pesticide contamination of ground water in the United States--a review   总被引:2,自引:0,他引:2  
Over 70 pesticides have been detected in ground water. Aldicarb and atrazine along with the soil fumigants EDB and DCP and DBCP have been the pesticides most frequently detected in ground water. Atrazine concentrations have been correlated with high nitrate concentrations. The triazine herbicides, simazine and cyanazine, have also been detected in ground water. The annual amount of recharge, soil type, depth of aquifer from the surface, nitrate contamination and soil pH are important field parameters in determining ground-water contamination potential by pesticides. Pesticide leaching is reduced by proper choice of crop rotation, increasing pesticide application efficiency, and integrated pest management.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号