全文获取类型
收费全文 | 129篇 |
免费 | 3篇 |
国内免费 | 11篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 11篇 |
环保管理 | 15篇 |
综合类 | 32篇 |
基础理论 | 10篇 |
污染及防治 | 50篇 |
评价与监测 | 16篇 |
社会与环境 | 4篇 |
灾害及防治 | 1篇 |
出版年
2022年 | 2篇 |
2021年 | 2篇 |
2020年 | 2篇 |
2019年 | 3篇 |
2018年 | 1篇 |
2017年 | 7篇 |
2016年 | 11篇 |
2015年 | 7篇 |
2014年 | 8篇 |
2013年 | 11篇 |
2012年 | 11篇 |
2011年 | 10篇 |
2010年 | 5篇 |
2009年 | 8篇 |
2008年 | 5篇 |
2007年 | 16篇 |
2006年 | 7篇 |
2005年 | 7篇 |
2004年 | 10篇 |
2003年 | 6篇 |
2002年 | 3篇 |
2001年 | 1篇 |
排序方式: 共有143条查询结果,搜索用时 15 毫秒
1.
2.
Jeong Kyungjun Hong Jiyeon Lee Yongjin Yang Jiyeon Lim Youngwook Shin Dongchun Kim Changsoo 《Environmental science and pollution research international》2021,28(28):37506-37519
Environmental Science and Pollution Research - Preschool children aged 3–6 years are vulnerable to exposed to particulate matter (“PM10” and “PM2.5”). It is required... 相似文献
3.
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis). 相似文献
4.
Gas-liquid phase partitioning is a key physical property that can predict the environmental fate of a compound between two phases. Several environmental factors have been known to affect the gas-liquid phase partitioning. We investigated the influence of surfactant on the gas-liquid phase partitioning of hydrogen peroxide (H(2)O(2)). The surfactant used was ammonium perfluorooctanoate (APFO). H(2)O(2) solution containing the surfactant was equilibrated in a closed system and gas phase H(2)O(2) concentration was measured by the peroxyoxalate chemiluminescence (PO-CL) method. Gas phase H(2)O(2) concentrations remained constant below the critical micelle concentration (CMC) and increased linearly with surfactant concentration above the CMC, which indicated that surfactant micelles influenced the gas-liquid phase partitioning of H(2)O(2). This result showed that H(2)O(2)-micelle interactions are less favorable than H(2)O(2)-H(2)O interactions. Surfactant monomers did not affect the gas-liquid phase partitioning of H(2)O(2) due to the absence of micelles. Solvent (methanol) effect was also investigated and showed that gas phase H(2)O(2) concentrations increased with the addition of solvent. This indicated the unfavorable interaction of H(2)O(2) with hydrophobic medium compared to hydrophilic one. It is consistent with the result that H(2)O(2)-micelles has a weaker interaction than H(2)O(2)-water because surfactant micelles are hydrocarbon-like organic phase rather than aqueous phase. 相似文献
5.
Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit 总被引:2,自引:0,他引:2
Geun Jeong B Min Yoon S Ho Choi C Koang Kwon K Sik Hyun M Heui Yi D Soo Park H Kim M Joo Kim H 《Journal of environmental monitoring : JEM》2007,9(12):1352-1357
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries. 相似文献
6.
The removal of elemental mercury (Hg(0)) with the reactive species produced from dielectric barrier discharge (DBD) was studied. The effects of the operating parameters, such as the applied voltage, residence time, initial concentration and co-existence of other pollutants, were investigated. The removal of Hg(0) was significantly promoted by an increase in the applied voltage of the DBD reactor system. The presence of NO gas decreased the Hg(0) removal efficiency within the range of input powers tested compared to the case of Hg(0)-only due to the competition for ozone between Hg(0) and NO gas in the DBD reactor. 相似文献
7.
Jung Hwan Oh Eui-Jong Lee Jeong Ik Oh Jong-Oh Kim Am Jang 《Environmental science and pollution research international》2016,23(8):7074-7080
As cities are becoming increasingly aware of problems related to conventional mobile collection systems, automated pipeline-based vacuum collection (AVAC) systems have been introduced in some densely populated urban areas. The reasons are that in addition to cost savings, AVAC systems can be efficient, hygienic, and environmentally friendly. Despite difficulties in making direct comparisons of municipal waste between a conventional mobile collection system and an AVAC system, it is meaningful to measure the quantities in each of these collection methods either in total or on a per capita generation of waste (PCGW, g/(day*capita)) basis. Thus, the aim of this study was to assess the difference in per capita generation of household waste according to the different waste collection methods in Korea. Observations on household waste show that there were considerable differences according to waste collection methods. The value of per capita generation of food waste (PCGF) indicates that a person in a city using AVAC produces 60 % of PCGF (109.58 g/(day*capita)), on average, compared with that of a truck system (173.10 g/(day*capita)) as well as 23 %p less moisture component than that with trucks. The value of per capita generation of general waste (PCGG) in a city with an AVAC system showed 147.73 g/(day*capita), which is 20 % less than that with trucks delivered (185 g/(day*capita)). However, general waste sampled from AVAC showed a 35 %p increased moisture content versus truck delivery. 相似文献
8.
Se-min Jeong Toru Sato Baixin Chen Shigeru Tabeta 《International Journal of Greenhouse Gas Control》2010,4(1):64-72
The direct injection of CO2 into the deep ocean is one of the ways for the mitigation of the global warming. There is, however, a concern about its environmental impact near the injection point. To minimize its biological impact, it is necessary to make CO2 disperse as fast as possible and it is thought that injection with pipes towed by moving-ships is effective for this purpose. Because the injection ships are planned to move in the site, the order of magnitude of which is 102 km, a mesoscale model is required to predict CO2 fate in seawater. At the same time, it is required to predict the concentration precisely near the injection points, which move with the ships in the mesoscale domain. In this study, a multi-scale ocean model was developed to analyze the dispersion of CO2 in the deep ocean: the model consists of a fixed mesoscale domain and 5 small-scale domains nesting in the mesoscale domain. Each small-scale domain involves 6 pipes and moves along with the trajectories of the injection ships. From the results of the present numerical simulation, the developed technique demonstrated its applicability as a tool to optimise the system to dilute CO2 below some criterion of biological impact. 相似文献
9.
Rokjin J. Park Minjoong J. Kim Jaein I. Jeong Daeok Youn Sangwoo Kim 《Atmospheric environment (Oxford, England : 1994)》2010,44(11):1414-1421
Brown carbon aerosols were recently found to be ubiquitous and effectively absorb solar radiation. We use a 3-D global chemical transport model (GEOS-Chem) together with aircraft and ground based observations from the TRACE-P and the ACE-Asia campaigns to examine the contribution of brown carbon aerosol to the aerosol light absorption and its climatic implication over East Asia in spring 2001. We estimated brown carbon aerosol concentrations in the model using the mass ratio of brown carbon to black carbon (BC) aerosols based on measurements in China and Europe. The comparison of simulated versus observed aerosol light absorption showed that the model accounting for brown carbon aerosol resulted in a better agreement with the observations in East Asian-Pacific outflow. We then used the model results to compute the radiative forcing of brown carbon, which amounts up to ?2.4 W m?2 and 0.24 W m?2 at the surface and at the top of the atmosphere (TOA), respectively, over East Asia. Mean radiative forcing of brown carbon aerosol is ?0.43 W m?2 and 0.05 W m?2 at the surface and at the TOA, accounting for about 15% of total radiative forcing (?2.2 W m?2 and 0.33 W m?2) by absorbing aerosols (BC + brown carbon aerosol), having a significant climatic implication in East Asia. 相似文献
10.
Implications of Conceptual Channel Representation on SWAT Streamflow and Sediment Modeling 下载免费PDF全文
Younggu Her Jaehak Jeong Katrin Bieger Hendrik Rathjens Jeffrey Arnold Raghavan Srinivasan 《Journal of the American Water Resources Association》2017,53(4):725-747
Hydrologic modeling outputs are influenced by how a watershed system is represented. Channel routing is a typical example of the mathematical conceptualization of watershed landscape and processes in hydrologic modeling. We investigated the sensitivity of accuracy, equifinality, and uncertainty of Soil and Water Assessment Tool (SWAT) modeling to channel dimensions to demonstrate how a conceptual representation of a watershed system affects streamflow and sediment modeling. Results showed the amount of uncertainty and equifinality strongly responded to channel dimensions. On the other hand, the model performance did not significantly vary with the changes in the channel representation due to the degree of freedom allowed by the conceptual nature of hydrologic modeling in the parameter calibration. Such findings demonstrated good modeling performance statistics do not necessarily mean small output uncertainty, and partial improvements in the watershed representation may neither increase modeling accuracy nor reduce uncertainty. We also showed the equifinality and uncertainty of hydrologic modeling are case‐dependent rather than specific to models or regions, suggesting great caution should be used when attempting to transfer uncertainty analysis results to other modeling studies, especially for ungauged watersheds. Editor's note: This paper is part of the featured series on SWAT Applications for Emerging Hydrologic and Water Quality Challenges. See the February 2017 issue for the introduction and background to the series. 相似文献