全文获取类型
收费全文 | 93篇 |
免费 | 2篇 |
国内免费 | 4篇 |
专业分类
安全科学 | 5篇 |
废物处理 | 3篇 |
环保管理 | 8篇 |
综合类 | 14篇 |
基础理论 | 13篇 |
环境理论 | 1篇 |
污染及防治 | 31篇 |
评价与监测 | 15篇 |
社会与环境 | 9篇 |
出版年
2023年 | 1篇 |
2022年 | 3篇 |
2021年 | 6篇 |
2020年 | 6篇 |
2019年 | 4篇 |
2018年 | 2篇 |
2017年 | 9篇 |
2016年 | 4篇 |
2015年 | 4篇 |
2014年 | 1篇 |
2013年 | 2篇 |
2012年 | 3篇 |
2011年 | 3篇 |
2010年 | 3篇 |
2009年 | 3篇 |
2008年 | 7篇 |
2007年 | 6篇 |
2006年 | 12篇 |
2005年 | 11篇 |
2004年 | 4篇 |
2003年 | 3篇 |
2001年 | 1篇 |
1999年 | 1篇 |
排序方式: 共有99条查询结果,搜索用时 15 毫秒
61.
Mikhailuta SV Taseiko OV Pitt A Lezhenin AA Zakharov YV 《Environmental monitoring and assessment》2009,149(1-4):329-341
This paper examines the significant differences in seasonal variations of criteria pollutant concentrations in various parts of a large urban area. These differences are caused by the microclimatic heterogeneity of the city and show the influence of breeze and orographic-type circulations on urban air pollution. The temperature heterogeneity of Krasnoyarsk territory during the winter leads to an increase of 150% in CO air pollution levels in the central part of city. During the summer the orographical heterogeneity of Krasnoyarsk City leads to increases of up to 400% in air pollution for different areas. 相似文献
62.
Stef Bokhorst Stine Højlund Pedersen Ludovic Brucker Oleg Anisimov Jarle W. Bjerke Ross D. Brown Dorothee Ehrich Richard L. H. Essery Achim Heilig Susanne Ingvander Cecilia Johansson Margareta Johansson Ingibjörg Svala Jónsdóttir Niila Inga Kari Luojus Giovanni Macelloni Heather Mariash Donald McLennan Gunhild Ninis Rosqvist Atsushi Sato Hannele Savela Martin Schneebeli Aleksandr Sokolov Sergey A. Sokratov Silvia Terzago Dagrun Vikhamar-Schuler Scott Williamson Yubao Qiu Terry V. Callaghan 《Ambio》2016,45(5):516-537
63.
64.
Singh U Levin L Grinshpun SA Schaffer C Adhikari A Reponen T 《Journal of environmental monitoring : JEM》2011,13(11):3246-3253
The aim of this study was to assess the associations between airborne and dustborne microbial contaminants (endotoxin and β-D-glucan) and estimate the effects of home characteristics on exposure levels of these microbial contaminants. Endotoxin and β-D-glucan concentrations in airborne inhalable particles, airborne PM1 (<1 μm) and vacuumed dust from 184 residential homes were determined using specific Limulus amebocyte assays. Home characteristics were recorded by visual inspection and questionnaires. Linear regression and correlation analyses were performed. Inhalable endotoxin correlated with dust endotoxin (r = 0.34, p < 0.001) and PM1 endotoxin (r = 0.33, p < 0.001). Inhalable β-D-glucan correlated with dust β-D-glucan (r = 0.18, p < 0.01), but not with PM1 β-D-glucan. Significant correlation was also found between PM1 and dust concentrations for endotoxin (r = 0.26, p < 0.001), but not for β-D-glucan. Multivariate regression analyses showed only one significant association between airborne contaminants and environmental characteristics: inhalable β-D-glucan was positively associated with relative humidity with an effect size (change in the dependent variable corresponding to a unit increase in the independent variable) of 2.32 and p < 0.05. In contrast, several associations were found between dust concentrations and environmental characteristics. Dust endotoxin was positively associated with temperature (2.87, p < 0.01) and number of inhabitants (2.76, p < 0.01), whereas dust β-D-glucan was inversely associated with the presence of dogs (-2.24, p < 0.05) and carpet (-3.05, p < 0.01) in the home. In conclusion, dustborne contaminants were more strongly affected by home characteristics than airborne contaminants. Furthermore, even though statistically significant, the correlations between airborne and dustborne contaminants were weak. This indicates that airborne concentrations cannot be reliably predicted based on dustborne concentrations. 相似文献
65.
Britigan N Alshawa A Nizkorodov SA 《Journal of the Air & Waste Management Association (1995)》2006,56(5):601-610
Indoor air purifiers are advertised as safe household products for health-conscious individuals, especially for those suffering from allergies and asthma. However, certain air purifiers produce ozone (O3) during operation, either intentionally or as a byproduct of air ionization. This is a serious concern, because O3 is a criteria air pollutant regulated by health-related federal and state standards. Several types of air purifiers were tested for their ability to produce ozone in various indoor environments at 40-50% relative humidity, including office rooms, bathrooms, bedrooms, and cars. O3 levels generated by personal wearable air purifiers were also tested. In many cases, O3 concentrations were well in excess of public and/or industrial safety levels established by U.S. Environmental Protection Agency, California Air Resources Board, and Occupational Safety and Health Administration. Simple kinetic equations were obtained that can predict the steady-state level of O3 in a room from the O3 emission rate of the air purifier and the first-order decay rate of O3 in the room. The additivity of O3 levels generated by independent O3 generators was experimentally demonstrated. 相似文献
66.
Hu S McDonald R Martuzevicius D Biswas P Grinshpun SA Kelley A Reponen T Lockey J Lemasters G 《Atmospheric environment (Oxford, England : 1994)》2006,40(Z2):378-395
The "Cincinnati Childhood Allergy and Air Pollution Study (CCAAPS)" is underway to determine if infants who are exposed to diesel engine exhaust particles are at an increased risk for atopy and atopic respiratory disorders, and to determine if this effect is magnified in a genetically at risk population. In support of this study, a methodology has been developed to allocate local traffic source contributions to ambient PM(2.5) in the Cincinnati airshed. As a first step towards this allocation, UNMIX was used to generate factors for ambient PM(2.5) at two sites near at interstate highway. Procedures adopted to collect, analyze and prepare the data sets to run UNMIX are described. The factors attributed to traffic sources were similar for the two sites. These factors were also similar to locally measured truck engine-exhaust enriched ambient profiles. The temporal variation of the factors was analyzed with clear differences observed between factors attributed to traffic sources and combustion-related regional secondary sources. 相似文献
67.
Two papers recently published in the Journal of Contaminant Hydrology by Marshall et al. [Marshall, B.D., Neymark, L.A., Peterman, Z.E., 2003. Estimation of past seepage volumes from calcite distribution in the Topopah Spring Tuff, Yucca Mountain, Nevada. J. Contam. Hydrol. 62-63, 237-247] and Xu et al. [Xu, T., Sonnenthal, E., Bodvarsson, G., 2003. A reaction-transport model for calcite precipitation and evaluation of infiltration fluxes in unsaturated fractured rock. J. Contam. Hydrol. 64, 113-127] attempt to assess past volumes of seepage and infiltration fluxes through the vadose zone of Yucca Mountain, Nevada, on the basis of the modeling of the spatial distribution of secondary calcite. In this commentary, we argue that the employed methodology is not viable. In addition, the thermal boundary conditions used in simulations do not correspond to the temperatures of the mineral forming fluids established on the basis of the fluid inclusion studies. 相似文献
68.
Recent trends in the decomposition of chlorinated aromatic hydrocarbons by ultrasound irradiation and Fenton's reagent 总被引:1,自引:0,他引:1
Jun Liang Sergey Komarov Naohito Hayashi Eiki Kasai 《Journal of Material Cycles and Waste Management》2007,9(1):47-55
Over the past few years, a large number of studies have been conducted on the use of ultrasound for decomposition of harmful
organic pollutants, particularly chlorinated aromatic hydrocarbons (CAH) in wastewater. The published reports cover a variety
of applications, including both ultrasonic treatment alone and in combination with other methods, e.g., advanced chemical
oxidation processes. This article presents a review of recent work on ultrasonic-based methods of CAH decomposition, with
emphasis on the applications of ultrasound alone and in combination with Fenton's reagent, as attractive advanced oxidation
systems. In the first part of this review, the basic principles of sonochemical treatment are presented, followed by a review
of the applications of ultrasound alone for CAH degradation. In the second part, the mechanisms of CAH degradation with Fenton's
reagent and its application for CAH degradation are summarized. In the final part, studies on the applications of ultrasound
together with Fenton's reagent are reviewed. The reported results suggest that a combination of ultrasound and Fenton's reagent
is more attractive for practical application than the use of either method separately. Further studies, however, are required
in this area because the reaction mechanism and the relationship between the reaction rates and process parameters for such
a combined process are not yet well established. 相似文献
69.
Kakareka SV Kukharchyk TI Khomich VS 《Environmental pollution (Barking, Essex : 1987)》2005,133(2):383-387
The procedure for and results of a test study of polycyclic aromatic hydrocarbon (PAH) emission from a few types of solid fuels combustion in residential furnaces of various designs typical for Belarus are discussed. Greatest levels of PAH emission were detected from domestic wastes and wood waste combustion. Lowest levels of PAH emission are from peat briquette combustion. It was found that PAH concentration in off-gases from firewood combustion also varies significantly depending on the type of wood: the highest values of PAH are typical for waste gases from birch firewood combustion in comparison with pine firewood combustion. Draft PAH emission factors are proposed with intended application for emission inventory of such installations. 相似文献
70.