The separation and determination of sub-μmol/l levels of six environmentally significant As compounds was accomplished by
means of high performance liquid chromatography (HPLC) combined online with inductively coupled plasma mass spectrometry (ICP-MS).
The species of interest (arsenite and arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine and arsenocholine)
were quantified in fish and mussel extracts after separation on a Dionex AS7 column equipped with an on-guard AG7 column using
a bicarbonate buffer as the mobile phase in a gradient mode. The species thus eluted were directly forwarded to the ICP-MS
detector. The detection power of the overall system allows each As form to be determined at concentrations as low a 0.0013–0.0027
μmol 1−1. 相似文献
The only documentation on the building downwash algorithm in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model), referred to as PRIME (Plume Rise Model Enhancements), is found in the 2000 A&WMA journal article by Schulman, Strimaitis and Scire. Recent field and wind tunnel studies have shown that AERMOD can overpredict concentrations by factors of 2 to 8 for certain building configurations. While a wind tunnel equivalent building dimension study (EBD) can be conducted to approximately correct the overprediction bias, past field and wind tunnel studies indicate that there are notable flaws in the PRIME building downwash theory. A detailed review of the theory supported by CFD (Computational Fluid Dynamics) and wind tunnel simulations of flow over simple rectangular buildings revealed the following serious theoretical flaws: enhanced turbulence in the building wake starting at the wrong longitudinal location; constant enhanced turbulence extending up to the wake height; constant initial enhanced turbulence in the building wake (does not vary with roughness or stability); discontinuities in the streamline calculations; and no method to account for streamlined or porous structures.
Implications: This paper documents theoretical and other problems in PRIME along with CFD simulations and wind tunnel observations that support these findings. Although AERMOD/PRIME may provide accurate and unbiased estimates (within a factor of 2) for some building configurations, a major review and update is needed so that accurate estimates can be obtained for other building configurations where significant overpredictions or underpredictions are common due to downwash effects. This will ensure that regulatory evaluations subject to dispersion modeling requirements can be based on an accurate model. Thus, it is imperative that the downwash theory in PRIME is corrected to improve model performance and ensure that the model better represents reality. 相似文献
Environmental Science and Pollution Research - Bisphenol-A is widely used chemical in industry and unfortunately often detected in natural waters. Considered as an emerging pollutant, bisphenol-A... 相似文献
Controlled bench-scale laboratory experiments were conducted to evaluate the recovery of ammonia (NH3) and hydrogen sulfide (H2S) from dynamic isolation flux chambers. H2S (80-4000 ppb) and NH3 (5000-40,000 ppb) samples were diffused through the flux chamber to simulate ground level area source emissions while measuring the inlet and outlet flux chamber concentrations simultaneously. Results showed that the recovery of H2S during a 30-min sampling time was almost complete for concentrations >2000 ppb. At the lowest concentration of 80 ppb, 92.55% of the H2S could be recovered during the given sampling period. NH3 emissions exhibited similar behavior between concentrations of 5000-40,000 ppb. Within the 30-min sampling period, 92.62% of the 5000-ppb NH3 sample could be recovered. Complete recovery was achieved for concentrations >40,000 ppb. Predictive equations were developed for gas adsorption. From these equations, the maximum difference between chamber inlet and outlet concentrations of NH3 or H2S was predicted to be 7.5% at the lowest concentration used for either gas. In the calculation of emission factors for NH3 and H2S, no adsorption correction factor is recommended for concentrations >37,500 ppb and 2100 ppb for NH3 and H2S, respectively. The reported differences in outlet and inlet concentration above these ranges are outside the fullscale sensitivity of the gas sensing equipment. The use of 46-90 m of Teflon tubing with the flux chambers has apparently no effect on gas adsorption, because recovery was completed almost instantaneously at the beginning of the tests. 相似文献
Environmental Science and Pollution Research - The order Odonata has been regularly used as an indicator of the ecosystem’s condition. The objective of this review was to analyze the... 相似文献
A chemical method for destroying the 2,3,7,8-TCDD is reported; it provides gradual and progressive substitution of the chlorine atoms by hydrogen atoms. The dehalogenation is promoted by a mixture made up of polyethyleneglycols (high molecular weight) of a weak base (K2 CO3) and of an inorganic peroxide (Na2 O2) which begins the radical process. The organic chlorine is transformed into inorganic chloride.The reaction mixture administered to male guinea-pigs did not lead to any direct or histological effect. 相似文献
Sustainable development, as a multi-dimensional concept, is difficult to measure. Some efforts using indicators and indices have appeared in recent years, but most were developed on a national scale. Use of sustainability indicators has proven valuable for attaining better management of the environment by minimizing information gaps and maximizing community capabilities in terms of economic, social, environmental, and institutional sustainability dimensions. However, at least in the case of developing countries, the potential exists that national sustainability measures, based on national level indicators, may mask problems in sub-national zones with highly unsustainable conditions. This paper proposes a methodology to evaluate sustainable development at a local level, the use of which could be helpful in comparing different regions within a country or even among different countries. National sustainability indicators should result from a combination (whether additive or proportional) of regional sustainability indicators, as developed in this paper. 相似文献
In order to characterize the different sources of exposure to arsenic (As), urinary excretion of total As, the sum of inorganic As+MMA+DMA determined by the hydride generation-atomic absorption spectrophotometry technique, and the species As(3), As(5), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and arsenobetaine were determined in 49 workers at a steel foundry, with presumed occupational exposure to As, and 50 subjects from the general population, all males. No evidence of occupational exposure to As resulted from environmental monitoring performed in the foundry, although the analysis of minerals used as raw materials showed the presence of As, particularly in fossils and fine ores. The urinary concentrations of As(3), MMA, DMA, the sum of inorganic As+MMA+DMA and total As were not different in the two groups, while arsenobetaine appeared significantly higher in the controls than in the workers. The different species of urinary As were all significantly correlated. Urinary excretion of As(3) was associated with the consumption of mineral water and with residence in an industrial zone, while MMA, DMA, arsenobetaine, the sum of inorganic As+MMA+DMA and total As urinary excretion were associated with the consumption of crustaceans and/or shellfish 3 days or less before urine collection. Multiple regression analysis confirmed these results. In conclusion, in populations with a high consumption of seafood, living in areas characterized by coastal/marine As pollution, only speciation of As can identify a prevalent role of environmental sources, like the consumption of seafood contaminated by As, in determining urinary As excretion, and exclude an occupational origin of the exposure. 相似文献
Scale-up of anodic oxidation system is critical to the practical application of electrochemical treatment in bio-refractory organic wastewater treatment. In this study, the scale-up of electrochemical flow system was investigated by treating petrochemical wastewater using platinized titanium (Ti/Pt) and boron-doped diamond (BDD) anodes. It was demonstrated that flow cell was successfully scaled-up because when it was compared with batch mode (Rocha et al. 2012b), higher performances on organic matter removal were achieved. Under the suitable operating conditions and better anode material, the chemical oxygen demand (COD) of petrochemical wastewater was reduced from 2,746 to 200 mg L?1 within 5 h with an energy consumption of only 56.2 kWh m?3 in the scaled-up BDD anode system. These results demonstrate that anode flow system is very promising in practical bio-refractory organic wastewater treatment. 相似文献
In this paper, in an attempt to reveal possible changes connected to natural or anthropogenic causes, the main results of hydrogeochemical monitoring carried out at Mount Etna are evaluated. We report on the salinity contents of the groundwaters that flow in fractured volcanics, which make up the flanks of the volcano. These waters, analyzed for major ion chemistry, were sampled regularly from 1994 to 2004. Basing on nonparametric Sen??s slope estimator, time series of groundwater composition reveal that the salinity of most of the Etnean aquifers increased by 0.5% to 3.5% each year during this period. This change in the water chemistry is clearly referable to the overexploitation of the aquifers. This increasing trend needs to be inverted urgently; otherwise, it will cause a shortage of water in the near future, because the maximum admissible concentration of salinity for drinking water will be exceeded. 相似文献