首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   142篇
  免费   1篇
安全科学   5篇
废物处理   13篇
环保管理   8篇
综合类   8篇
基础理论   22篇
污染及防治   38篇
评价与监测   45篇
社会与环境   3篇
灾害及防治   1篇
  2023年   6篇
  2022年   9篇
  2021年   9篇
  2020年   3篇
  2019年   4篇
  2018年   8篇
  2017年   5篇
  2016年   8篇
  2015年   6篇
  2014年   14篇
  2013年   21篇
  2012年   2篇
  2010年   7篇
  2009年   12篇
  2008年   7篇
  2007年   7篇
  2006年   5篇
  2005年   2篇
  2003年   3篇
  2001年   1篇
  2000年   2篇
  1995年   1篇
  1966年   1篇
排序方式: 共有143条查询结果,搜索用时 46 毫秒
61.
This study addresses the odor problem at a waste and residue treatment incineration and utilization plant located within the borders the Alikahya district of the Kocaeli province in Turkey. In the first stage of the study, odor measurements were made at designated sampling points, while in the second stage, odor concentrations were determined at the receptor points through dispersion modelling using a USEPA (United States Environmental Protection Agency) certified long-range (>50 km) CALPUFF lagrangian puff model. In the final stage, an analysis of the predicted and observed values was carried out using such statistical methods as geometric mean bias (MG), geometric variance (VG) and fractions of predictions within a factor of two observations (FAC2).

During the modelling study, the highest one-hour concentration level was found to be 1868.10 OU (Odor Units), and the 24-hour concentration level was found to be 1316 OU, representing a decrease of approximately 30 percent. According to the measurement made, the maximum concentration value was 2455 OU. Odor measurements were carried out at 13 points within the area in order to assess the prediction results. When the results were assessed using the MG, VG and FAC2 statistical methods, it was observed that an acceptable model performance was not achieved for the whole sampling point. When the reason for this was investigated, it was concluded that the observed values were lower than the predicted values due to the fact on the measurement days, the odor was dispersed by wind. It was further concluded that the observed values were higher than the predicted values as a result of odors emitted by other plants in the area. When the measurements in residential areas were examined to identify the effect of the odors, it was determined that although the primary density of settlement is to the southwest of the plant, it was not this area that was affected most, but rather the area to the northeast, where there is a lower settlement density.  相似文献   

62.
This study aims to identify precipitation, throughfall, stemflow, precipitation, and interception processes in pure black pine, pure Scots pine, and mixed black pine–Scots pine forest ecosystems and present the precipitation partitioning according to different stand types. Throughfall and stemflow measurements were performed using five standard precipitation gauges in a pilot area established to represent pure black pine, pure Scots pine, and mixed black pine–Scots pine stands in the Bezirgan Basin. The total precipitation was measured in an open field close to the study area. Throughfall values were calculated as the percentage of precipitation measured in an open field. According to the results of the study, the throughfall values were 69.8% in black pine, 73.9% in Scots pine, and 77.7% in the mixed black pine–Scots pine stands; the stemflow values were 2.6% in black pine, 5.9% in Scots pine, and 3.1% in the mixed black pine–Scots pine stands; the amounts of precipitation reaching the forest floor were 72.3% in black pine, 79.8% in Scots pine, and 80.7% in the mixed black pine–Scots pine stands; and the interception values were found to be 27.7% in black pine, 20.2% in Scots pine, and 19.2% in the mixed black pine–Scots pine stands.  相似文献   
63.
Heavy Metal Pollution of Surface Soil in the Thrace Region, Turkey   总被引:1,自引:0,他引:1  
Abstact Samples of surface soil were collected at 73 sites in the Thrace region, northwest part of Turkey. Two complementary analytical techniques, epithermal neutron activation analysis (ENAA) and atomic absorption spectrometry (AAS) with flame and graphite furnace atomization were used to determine 35 elements in the soil samples. Concentrations of As, Cd, Co, Cu, Mn, Ni, Pb and Zn were determined using AAS and GF AAS, and ENAA was used for the remaining 27 elements. Results for As, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu Eu, Fe, Hf, I, In, K, La, Mn, Mo, Na, Nd, Ni, Pb, Rb, Sb, Sc, Sm, Sr, Ta, Tb, Th, Ti, U, V and Zn are reported for the first time for soils from this region. The results show that concentrations of most elements were little affected by the industrial and other anthropogenic activities performed in region. Except for distinctly higher levels of Pb, Cu, Cd and Zn in Istanbul district than the median values for the Thrace region, the observed distributions seem to be mainly associated with lithogenic variations. Spatial distributions of As, Cd, Cr, Cu, Ni, Pb and Zn were plotted in relation to the concentration values in soil using Geographic Information System (GIS) technology  相似文献   
64.
This study analyses forest dynamics and land use/land cover change over a 43-year period using spatial-stand-type maps of temporal forest management plans of Karaisal? Forest Enterprise in the Eastern Mediterranean Region of Turkey. Stand parameters (tree species, crown closures and developmental stages) of the dynamics and changes caused by natural or artificial intervention were introduced and mapped in a Geographic Information System (GIS) and subjected to fragmentation analysis using FRAGSTATS. The Karaisal? Forest Enterprise was first planned in 1969 and then the study area was planned under the Mediterranean Forest Use project in 1991 and five-term forest management plans were made. In this study, we analysed only four periods (excluding 1982 revision plans): 1969, 1991, 2002 and 2012. Between 1969 and 2012, overall changes included a net increase of 3,026 ha in forested areas. Cumulative forest improvement accounted for 2.12 % and the annual rate of total forest improvement averaged 0.08 %. In addition, productive forest areas increased from 36,174 to 70,205 ha between 1969 and 2012. This translates into an average annual productive forest improvement rate of 1.54 %. At the same time, fully covered forest areas with crown closure of “3” (>70 %) increased about 21,321 ha, and young forest areas in developmental stage of “a” (diameter at breast height (dbh)?<?8 cm) increased from 716 to 13,305 ha over the 43-year study period. Overall changes show that productive and fully covered forest areas have increased egregiously with a focus on regenerated and young developmental stages. A spatial analysis of metrics over the 43-year study period indicated a more fragmented landscape resulting in a susceptible forest to harsh disturbances.  相似文献   
65.
In this study, surface water quality of the Ceyhan River basin were assessed and examined with 13 physico-chemical parameters in 31 stations in 3 months during the period of 2005. Multivariate statistical techniques were applied to identify characteristics of the water quality in the studied stations. Nutrients, Cl??? and Na?+? affected mostly to the stations of Erkenez 2, S?r 2, and S?r 3 in the ordination diagram of correspondence analysis. Three factors were extracted by principal component analysis, which explains 79.14% of the total variation. The first factor (PC1) captures variables of EC, DO, NO $_{2}^{\; -}$ , PO $_{4}^{\; \equiv }$ , Cl???, SO $_{4}^{\; =}$ , Na?+?, and Ca?+?+?. The second factor (PC2) is significantly related to pH, NH $_{3}^{\; -}$ , and Mg?+?+?, while water temperature (T) and NO $_{3}^{\; -}$ accounted for the greatest loading for factor 3 (PC3). The stations were divided into three groups for PC1, two groups for PC2, and three groups for PC3 by hierarchical cluster analysis. The stations in the vicinity of cities presented low dissolved oxygen and high concentration of physico-chemical parameter levels. The stations of Erkenez 2, S?r 2, S?r 3, and Aksu 4 located near the city of Kahramanmara? were characterized by an extremely high pollution due to discharge of wastewater from industry and domestic. P?narba?? and Elbistan stations were also influenced by household wastewater of the city of Elbistan. According to criteria of Turkish Water Pollution Control Regulation, Erkenez 2, S?r 2, and S?r 3 stations have high polluted water. This study suggests that it is urgent to control point pollutions, and all wastewater should be purified before discharge to the Ceyhan River basin.  相似文献   
66.
In this research, in order to determine mean fungus counts, indoor and outdoor air samples were taken in five elementary school buildings located in the city center of Seferihisar, Izmir (45 km from Izmir) within a 1-year period between March and April 2004, and between January and February 2005 representing similar climatic characteristics. Five samples, three from three classes where 5–8, 10–12, and 12–15 age group students attended, one from the corridors, and one from outside the buildings in all the schools, were taken for each period. Within the period of the study, in indoor and outdoor air samples, 7,122 microfungus colonies were counted. Sixty-four species were identified that belong to 17 genera as a result of the identification of isolates obtained. Skin prick tests were applied to 55 out of a total of 117 teachers by the clinicians. According to these test results, 24 teachers were sensitive to at least one agent. Results revealed that, in terms of mold counts, the difference between the schools and the difference between the times (periods) were statistically significant (p?< 0.05).  相似文献   
67.
The water used in dental unit waterlines (DUWLs) acts as a coolant for the high-speed equipment and as an irrigant during dental treatments. There are kind of water tanks. DUWLs provide a favorable environment for microbial biofilm and multiplation primarily due to the high surface in the tubing and the character of fluid dynamics in narrow, smooth-walled waterlines. Biofilms can harbour opportunist pathogens such as Legionella sp., Pseudomonas sp. Several studies have shown that DUWLs have high levels of microbial contamination. Presence of high level of microbial contamination is an important problem for dentists and dental patients who are immunocompromised. We collected water samples from DUWLs of 20 private dental offices. We have determined that only 2 (3.4%) out of 59 dental unit water samples were found to meet the standard (<200 CFU.ml(-1)) for DUWLs water quality by American Dental Association (ADA). Of the 59 water samples examined, 14 (24%) were positive for Pseudomonas sp. and 18 (30.5%) were positive for fungi. The most common 14 bacterial strains and seven fungi were isolated. Of bacterial strains, 57.1% were identified: Majority of the bacterial species isolated from our samples was identified as Pseudomonas fluorescens, Pasteurella haemolytica, Photobacterium damsela, Ochrobacter anthropi, Moraxella sp., Aspergillus flavus, Penicillium expansum. Legionella sp. were not detected in all water samples.  相似文献   
68.
Ecological monitoring is a complementary component of the overall environmental management and monitoring program of any Environmental Impact Assessment (EIA) report. The monitoring method should be developed for each project phase and allow for periodic reporting and assessment of compliance with the environmental conditions and requirements of the EIA. Also, this method should incorporate a variance request program since site-specific conditions can affect construction on a daily basis and require time-critical application of alternative construction scenarios or environmental management methods integrated with alternative mitigation measures. Finally, taking full advantage of the latest information and communication technologies can enhance the quality of, and public involvement in, the environmental management program. In this paper, a landscape-scale ecological monitoring method for major construction projects is described using, as a basis, 20 months of experience on the Baku-Tbilisi-Ceyhan (BTC) Crude Oil Pipeline Project, covering Turkish Sections Lot B and Lot C. This analysis presents suggestions for improving ecological monitoring for major construction activities.  相似文献   
69.
This paper concentrates on determining the areas for afforestation and the development of conservation strategies and actions in the case where there is high demand for the conservation of a particular land area. The analysis of hydrological landscape structure and of erodibility was prerequisite in the methodological design considering the site-specific natural landscape characteristics of the study area. The Gölba?? Specially Protected Area (SPA) being the case area has many local environmental disturbances, especially with respect to its hydrological system, and the area is beset by increasing demands for its use by the burgeoning human population. It is obviously clear that the present intensive demand for recreational use will be forecasted further increase in the future. The count of rural residences is estimated to increase by 50% over the next decade. This intensive demand shall further strain the carrying capacity of the ecological milieu, which has already suffered to a significant degree because of the present urban and rural activities. The Gölba?? district is located only 20 km from the city center of Ankara, and its surroundings were legally designated to be a Specially Protected Area primarily for the existence of lacustral and fluvial systems where two interconnected lakes exist: Mogan and E?mir Lakes. Essentially, the continuity of the lacustral and fluvial system of Lakes Mogan and E?mir depends on the preservation and improvement of the water sources. However, interconnected surface water bodies of these lakes are actually quite contaminated, and a decline in the water flow from Mogan to E?mir has been observed. For the elaboration of the present method, required conventional maps (at 1/25,000 scale) of topography (for slope analysis) and geology (for erodibility and permeability analysis) were transferred to computer media using AutoCAD® R.14 software. The rectification of the transferred data was done using ERDAS® Imagine 8.3. All data were then transferred into a GIS engine (Arcview® 3.2). This software provided the ability to create, manipulate, analyze and display topologically correct geographic data in digital form. The method proceeded according to the following phases: 1. Analysis of the hydrologic landscape structure; 2. Permeability of the soil structure; 3. Permeability of the geological structure; 4. Conservation zones.  相似文献   
70.
The aim of this study was to determine if high concentrations of any heavy metals exist in the sediment of Seyhan Dam reservoir to be considered toxic to the aquatic environment. Surface sediment samples from five stations in the Seyhan dam were collected quarterly from 2004 to 2005 and examined for metal content (Cr, Zn Cu, Mn, Cd, Fe, Ca, K, and Na), organic matter, and grain size. Correlation analyses showed that metal content of Seyhan dam sediment was affected by organic matter and grain size. The results have been compared with values given in the literature. The evaluation of the metal pollution status of the dam was carried out by using the enrichment factor and the geoaccumulation index. A comparison with sediment quality guideline values has also been made. Based on the enrichment factor, dam sediments were treated as a moderately severe enrichment with Cd and minor enrichment with Cr and Mn. The results of geoaccumulation index reveal that sediments of Seyhan Dam were strongly polluted in stations 1, 2, 4, and 5, and were moderately polluted in station 3 with Cd. Moreover, Cd and Cr concentrations in the sediments were above TECs except ERL for Cd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号