In this second paper of a series on groundwater seepage from uranium tailings, the general geochemical behavior of radionuclides is described and then applied to data from the field site, Seepage Area A of the Nordic Main impoundment near Elliot Lake, Ontario. The delineation of radionuclide behavior requires (1) the calculation of total element concentration by the summation of concentrations of each element's isotopes (the isotopic concentrations are calculated from the isotopes' radioactivities), (2) the evaluation of solid-liquid interactions using total element concentrations, and (3), for particular isotopes, the evaluation of the extent to which parental geochemical behavior causes a deviation in the isotope's behavior from that of its total element. A computerized speciation program, WATRAD, is used to evaluate aqueous complexation and mineral saturation indices of radium, actinium, thorium, and uranium. Data from Seepage Area A on isotopes of these four elements plus 210Pb show that the geochemical behavior of radionuclides can be best defined on an individual isotopic basis rather than on an elemental basis. 相似文献
Landscape approaches attempt to achieve balance amongst multiple goals over long time periods and to adapt to changing conditions. We review project reports and the literature on integrated landscape approaches, and found a lack of documented studies of their long-term effectiveness. The combination of multiple and potentially changing goals presents problems for the conventional measures of impact. We propose more critical use of theories of change and measures of process and progress to complement the conventional impact assessments. Theories of change make the links between project deliverables, outputs, outcomes, and impacts explicit, and allow a full exploration of the landscape context. Landscape approaches are long-term engagements, but short-term process metrics are needed to confirm that progress is being made in negotiation of goals, meaningful stakeholder engagement, existence of connections to policy processes, and effectiveness of governance. Long-term impact metrics are needed to assess progress on achieving landscapes that deliver multiple societal benefits, including conservation, production, and livelihood benefits. Generic criteria for process are proposed, but impact metrics will be highly situation specific and must be derived from an effective process and a credible theory of change. 相似文献
Dendrimer-functionalized multi-walled carbon nanotubes (MWCNT) for heavy metal ion removal from wastewaters were developed. Triazole dendrimers (TD) were built directly onto the carbon nanotube surface by successive click chemistry reactions affording the zero- and first-generation dendrimer-functionalized MWCNT (MWCNT-TD1 and MWCNT-TD2). The Moedritzer-Irani reaction carried out on the amino groups present on the MWCNT-TD2 sample gave the corresponding α-aminophosphonate nanosystem MWCNT-TD2P. Both MWCNT-TD2 and MWCNT-TD2P nanosystems have been characterized by physical, chemical, and morphological analyses. Their chelating abilities towards the toxic metal ions Pb2+, Hg2+, and Ni2+ and the harmless Ca2+ ion have been experimentally evaluated in the two different sets of experiments and at the salt concentrations of 1 mg/mL or 1 μg/mL by inductively coupled plasma mass spectrometry (ICP-MS). The results of these studies pointed out the interesting chelating behavior for the phosphonated nanosystem towards the Hg2+ ion. The complexation mode of the best chelating system MWCNT-TD2P with mercury was investigated through density functional theory (DFT) calculations, suggesting a chelation mechanism involving the two oxygen atoms of the phosphate group. The synthesized dendrimers, supported on the multi-walled carbon nanotubes, have shown the potential to be used for the selective toxic metal ion removal and recovery. 相似文献
The aim of this work is to study the colour and chemical modifications of the surfaces in chestnut wood samples as a consequence of irradiating in a controlled environment. The changes were investigated by a new analytical approach by combining traditional techniques such as reflectance spectrophotometry in the visible range and Fourier transform infrared spectroscopy with new hyperspectral imaging, in order to obtain forecast models to describe the phenomenon. The statistical elaboration of the experimental data allowed to validate the measurements and to obtain models enabling to relate the investigated parameters; the elaboration of the hyperspectral images by chemometric methods allowed for studying the changes in the reflectance spectra. A result of great importance is the possibility to correlate the oxidation of wood chemical components with the colour change in a totally non-invasive modality. This result is particularly relevant in the field of cultural heritage and in general in the control processes of wooden materials. 相似文献
Environmental Science and Pollution Research - This work supports, for the first time, the integrated management of waste materials arising from industrial processes (fly ash from municipal solid... 相似文献
Regional Environmental Change - Increased dieback and mortality of “dark needle conifer” (DNC) stands (composed of fir (Abies sibirica), Siberian pine (Pinus sibirica) and spruce (Picea... 相似文献
There is concern about the hazard of acute residential CO exposures from portable gasoline-powered generators, which can result in death or serious adverse health effects in exposed individuals. To address this hazard, the U.S. Consumer Product Safety Commission has developed low CO emission prototype generators by adapting off-the-shelf emission control technologies onto commercially available generators. A series of tests was conducted to characterize the indoor CO concentrations resulting from portable generators operating in the attached garage of a research house under seven different test house/garage configurations. The tested generators include both unmodified and modified low CO emission prototypes. It was found that CO concentrations varied widely, with peak house CO concentrations ranging from under 10 ppm to over 10,000 ppm. The highest concentrations in the house resulted from operation of the unmodified generator in the garage with the garage bay door closed and the house access door open. The lowest concentrations resulted from operation of a modified low CO emission prototype in the garage with the garage bay door open and the house access door closed. These tests documented reductions of up to 98% in CO concentrations due to emissions from two low CO emission portable generators compared to a stock generator.
Implications: Improper portable generator use has caused 800 U.S. deaths in the past 14 years. Generators operated in attached garages can cause CO to quickly reach deadly levels. Two low-emission prototypes generators were tested and had CO emissions reduced by up to 98%. Low-emission generators can reduce the risk of consumer poisonings and deaths. 相似文献
The only documentation on the building downwash algorithm in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model), referred to as PRIME (Plume Rise Model Enhancements), is found in the 2000 A&WMA journal article by Schulman, Strimaitis and Scire. Recent field and wind tunnel studies have shown that AERMOD can overpredict concentrations by factors of 2 to 8 for certain building configurations. While a wind tunnel equivalent building dimension study (EBD) can be conducted to approximately correct the overprediction bias, past field and wind tunnel studies indicate that there are notable flaws in the PRIME building downwash theory. A detailed review of the theory supported by CFD (Computational Fluid Dynamics) and wind tunnel simulations of flow over simple rectangular buildings revealed the following serious theoretical flaws: enhanced turbulence in the building wake starting at the wrong longitudinal location; constant enhanced turbulence extending up to the wake height; constant initial enhanced turbulence in the building wake (does not vary with roughness or stability); discontinuities in the streamline calculations; and no method to account for streamlined or porous structures.
Implications: This paper documents theoretical and other problems in PRIME along with CFD simulations and wind tunnel observations that support these findings. Although AERMOD/PRIME may provide accurate and unbiased estimates (within a factor of 2) for some building configurations, a major review and update is needed so that accurate estimates can be obtained for other building configurations where significant overpredictions or underpredictions are common due to downwash effects. This will ensure that regulatory evaluations subject to dispersion modeling requirements can be based on an accurate model. Thus, it is imperative that the downwash theory in PRIME is corrected to improve model performance and ensure that the model better represents reality. 相似文献