The only documentation on the building downwash algorithm in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model), referred to as PRIME (Plume Rise Model Enhancements), is found in the 2000 A&WMA journal article by Schulman, Strimaitis and Scire. Recent field and wind tunnel studies have shown that AERMOD can overpredict concentrations by factors of 2 to 8 for certain building configurations. While a wind tunnel equivalent building dimension study (EBD) can be conducted to approximately correct the overprediction bias, past field and wind tunnel studies indicate that there are notable flaws in the PRIME building downwash theory. A detailed review of the theory supported by CFD (Computational Fluid Dynamics) and wind tunnel simulations of flow over simple rectangular buildings revealed the following serious theoretical flaws: enhanced turbulence in the building wake starting at the wrong longitudinal location; constant enhanced turbulence extending up to the wake height; constant initial enhanced turbulence in the building wake (does not vary with roughness or stability); discontinuities in the streamline calculations; and no method to account for streamlined or porous structures.
Implications: This paper documents theoretical and other problems in PRIME along with CFD simulations and wind tunnel observations that support these findings. Although AERMOD/PRIME may provide accurate and unbiased estimates (within a factor of 2) for some building configurations, a major review and update is needed so that accurate estimates can be obtained for other building configurations where significant overpredictions or underpredictions are common due to downwash effects. This will ensure that regulatory evaluations subject to dispersion modeling requirements can be based on an accurate model. Thus, it is imperative that the downwash theory in PRIME is corrected to improve model performance and ensure that the model better represents reality. 相似文献
ABSTRACT Aerosol light absorption as black carbon (BC) was measured from November 19, 1995, to February 6, 1996, at a location 0.65 km downwind of the center of McMurdo Station on the Antarctic coast. The results show a bimo-dal frequency distribution of BC concentrations. Approximately 65% of the measurements were found in a mode at a low range of concentrations centered at ~20 ng/m3. These concentrations are higher than those found at other remote Antarctic locations and probably represent contamination from the station. The remaining measurements were in a high-concentration mode (BC ~300 ng/m3), indicating direct impact of local emissions from combustion activities at the station. High values of BC were associated with winds from the direction of the station, and the BC flux showed a clear directionality. Maximum BC concentrations occurred between 7:00 and 11:00 a.m. The "polluted" mode accounted for more than 80% of the BC frequency-weighted impact at this location. 相似文献
Coastal and freshwater eutrophication continues to accelerate at sites around the world despite intense efforts to control agricultural P loss using traditional conservation and nutrient management strategies. To achieve required reductions in nonpoint P over the next decade, new tools will be needed to address P transfers from soils and applied P sources. Innovative remediation practices are being developed to remove nonpoint P sources from surface water and groundwater using P sorbing materials (PSMs) derived from natural, synthetic, and industrial sources. A wide array of technologies has been conceived, ranging from amendments that immobilize P in soils and manures to filters that remove P from agricultural drainage waters. This collection of papers summarizes theoretical modeling, laboratory, field, and economic assessments of P removal technologies. Modeling and laboratory studies demonstrate the importance of evaluating P removal technologies under controlled conditions before field deployment, and field studies highlight several challenges to P removal that may be unanticipated in the laboratory, including limited P retention by filters during storms, as well as clogging of filters due to sedimentation. Despite the potential of P removal technologies to improve water quality, gaps in our knowledge remain, and additional studies are needed to characterize the long-term performance of these technologies, as well as to more fully understand their costs and benefits in the context of whole-farm- and watershed-scale P management. 相似文献
High levels of accumulated phosphorus (P) in soils of the Delmarva Peninsula are a major source of dissolved P entering drainage ditches that empty into the Chesapeake Bay. The objective of this study was to design, construct, and monitor a within-ditch filter to remove dissolved P, thereby protecting receiving waters against P losses from upstream areas. In April 2007, 110 Mg of flue gas desulfurization (FGD) gypsum, a low-cost coal combustion product, was used as the reactive ingredient in a ditch filter. The ditch filter was monitored from 2007 to 2010, during which time 29 storm-induced flow events were characterized. For storm-induced flow, the event mean concentration efficiency for total dissolved P (TDP) removal for water passing through the gypsum bed was 73 ± 27% confidence interval (α = 0.05). The removal efficiency for storm-induced flow by the summation of load method was 65 ± 27% confidence interval (α = 0.05). Although chemically effective, the maximum observed hydraulic conductivity of FGD gypsum was 4 L s(-1), but it decreased over time to <1 L s(-1). When bypass flow and base flow were taken into consideration, the ditch filter removed approximately 22% of the TDP load over the 3.6-yr monitoring period. Due to maintenance and clean-out requirements, we conclude that ditch filtration using FGD gypsum is not practical at a farm scale. However, we propose an alternate design consisting of FGD gypsum-filled trenches parallel to the ditch to intercept and treat groundwater before it enters the ditch. 相似文献
Agricultural technologies are non-neutral and ethical challenges are posed by these technologies themselves. The technologies
we use or endorse are embedded with values and norms and reflect the shape of our moral character. They can literally make
us better or worse consumers and/or people. Looking back, when the world’s developed nations welcomed and steadily embraced
industrialization as the dominant paradigm for agriculture a half century or so ago, they inadvertently championed a philosophy
of technology that promotes an insular human-centricism, despite its laudable intent to ensure food security and advance human
flourishing. The dominant philosophy of technology has also seeded particular ethical consequences that plague the well-being
of human beings, the planet, and farmed animals. After revisiting some fundamental questions regarding the complex ways in
which technology as agent shapes our lives and choices and relegates food and farmed constituents into technological artifacts or commodities, I argue
that we should accord an environmental virtue ethic of care—understood as caretaking—a central place in developing a more
conscientious philosophy of technology that aims at sustainability, fairness, and humaneness in animal agriculture. While
technology shapes society, it also is socially shaped and an environmental virtue ethic of care (EVEC) as an alternative design
philosophy has the tools to help us take a much overdue inventory of ourselves and our relationships with the nonhuman world.
It can help us to expose the ways in which technology hinders critical reflection of its capacity to alter communities and
values, to come to terms with why we may be, in general, disengaged from critical ethical analysis of contemporary agriculture
and to consider the moral shape and trajectory and the sustainability of our food production systems going into the future.
I end by outlining particular virtues associated with the ethic of care discussed here and consider some likely implications
for consumers and industry technocrats as they relate to farming animals. 相似文献
This field study investigated the phytoremediation potential of two arsenic (As) hyperaccumulating fern species, Pityrogramma calomelanos var. austroamericana and Pteris vittata over 27-month duration at a disused As-contaminated cattle-dip site located at Wollongbar, NSW, Australia. Ferns planted in January 2009 were harvested following 10, 22 and 27 months of growth. A detailed soil sampling was undertaken in June 2009 (initial, n?=?42 per plot) and limited sampling in April 2011 (after 27 months, n?=?15 per plot) to measure total and phosphate-extractable As concentrations in soil at 0?-?20-, 20?-?40- and 40?-?60-cm depths. The choice of the limited number of samples was considered sufficient to estimate the changes in soil As concentration following phytoremediation based on a geostatistical model. The average frond dry biomass, As concentration and As uptake were significantly (P?0.001?-?0.05) greater in P. calomelanos var. austroamericana than P. vittata, at all three harvests (1.6?-?4.3, 1.3?-?1.5 and 2.2?-?5.7 times, respectively). After 27-months of growth, P. calomelanos var. austroamericana removed 8,053 mg As (i.e. cumulative over three harvests) in plot B (25.4 kg As ha(-1)) that was 2.65 times higher than that depleted by P. vittata (3,042 mg As in plot A (9.7 kg As ha(-1))). The cumulative frond As uptake data of the two fern species revealed that P. calomelanos var. austroamericana extracted 1.7?-?3.9 % and P. vittata removed 0.53?-?1.5 % of total As from soil at three depths. However, for the surface (0?-?20 cm) and subsurface (40?-?60 cm) layers, the (post-experiment) soil As data indicated that total As concentration in soil was reduced by 49 and 63 % (P?0.05), respectively, using P. calomelanos var. austroamericana; and 17 and 15 % (P?>?0.05), respectively, by P. vittata. Our results show that phytoremediation time based on observed changes in soil As based on limited sampling is not reliable; hence, it is recommended that the frond As uptake should be considered in order to evaluate the phytoremediation efficiency of the two fern species at the experimental site. Using As uptake of the two fern species, we estimate that with P. calomelanos var. austroamericana it would take 55?-?125 years to decrease mean total As content below the ecological investigation level (20 mg kg(-1)) in the surface and subsurface soils, whereas with P. vittata 143?-?412 years would be required to achieve this target. 相似文献
Factors that diminish the effectiveness of phosphorus inputs from a municipal wastewater treatment facility (Metro) in contributing to phosphorus levels and its availability to support algae growth in a culturally eutrophic urban lake (Onondaga Lake, NY) were characterized and quantified. These factors included the bioavailability and settling characteristics of particulate phosphorus from this effluent, the dominant form (70%) of phosphorus in this input, and the plunging of the discharge to stratified layers in the lake. Supporting studies included: (1) chemical and morphometric characterization of the phosphorus-enriched particles of this effluent, compared to particle populations of the tributaries and lake, with an individual particle analysis technique; (2) conduct of algal bioavailability assays of the particulate phosphorus of the effluent; (3) conduct of multiple size class settling velocity measurements on effluent particles; and (4) determinations of the propensity of the discharge to plunge, and documentation of plunging through three-dimensional monitoring of a tracer adjoining the outfall. All of these diminishing effects were found to be operative for the Metro effluent in Onondaga Lake and will be integrated into a forthcoming phosphorus "total maximum daily load" analysis for the lake, through appropriate representation in a supporting mechanistic water quality model. The particulate phosphorus in the effluent was associated entirely with Fe-rich particles formed in the phosphorus treatment process. These particles did not contribute to concentrations in pelagic portions of the lake, due to local deposition associated with their large size. Moreover, this particulate phosphorus was found to be nearly entirely unavailable to support algae growth. While substantial differences are to be expected for various inputs, the effective loading concept and the approaches adopted here to assess the diminishing factors are broadly applicable. 相似文献
Can we develop land use policy that balances the conflicting views of stakeholders in a catchment while moving toward long term sustainability? Adaptive management provides a strategy for this whereby measures of catchment performance are compared against performance goals in order to progressively improve policy. However, the feedback loop of adaptive management is often slow and irreversible impacts may result before policy has been adapted. In contrast, integrated modelling of future land use policy provides rapid feedback and potentially improves the chance of avoiding unwanted collapse events. Replacing measures of catchment performance with modelled catchment performance has usually required the dynamic linking of many models, both biophysical and socio-economic—and this requires much effort in software development. As an alternative, we propose the use of variable environmental intensity (defined as the ratio of environmental impact over economic output) in a loose coupling of models to provide a sufficient level of integration while avoiding significant effort required for software development. This model construct was applied to the Motueka Catchment of New Zealand where several biophysical (riverine water quantity, sediment, E. coli faecal bacteria, trout numbers, nitrogen transport, marine productivity) models, a socio-economic (gross output, gross margin, job numbers) model, and an agent-based model were linked. An extreme set of land use scenarios (historic, present, and intensive) were applied to this modelling framework. Results suggest that the catchment is presently in a near optimal land use configuration that is unlikely to benefit from further intensification. This would quickly put stress on water quantity (at low flow) and water quality (E. coli). To date, this model evaluation is based on a theoretical test that explores the logical implications of intensification at an unlikely extreme in order to assess the implications of likely growth trajectories from present use. While this has largely been a desktop exercise, it would also be possible to use this framework to model and explore the biophysical and economic impacts of individual or collective catchment visions. We are currently investigating the use of the model in this type of application. 相似文献
Kallis, Jahn, Leo Bodensteiner, and Anthony Gabriel, 2010. Hydrological Controls and Freshening in Meromictic Soap Lake, Washington, 1939-2002. Journal of the American Water Resources Association (JAWRA) 46(4): 744-756. DOI: 10.1111/j.1752-1688.2010.00446.x Abstract: The chemically stratified layer of naturally formed meromictic lakes exhibits unusual and often extreme physical and chemical conditions that have resulted in the evolution of uniquely adapted species. The Columbia Basin Irrigation Project appears to have had a marked effect on the hydrology of Soap Lake, a meromictic lake in the Grand Coulee of central Washington. The relation of hydrology to salinity was assessed by analyzing water budgets before and after the introduction of the irrigation project. Before irrigation, water gains were balanced by losses; after irrigation began groundwater gains approximately doubled. To manage lake levels and reduce groundwater influx, wells were installed to intercept groundwater. Although the hydrological cycle has been restored to pre-irrigation conditions, the meromictic character of the lake continues to change. Interception wells remove 10 to 16 Mm3 of groundwater annually, but influx continues based on change in the monimolimnion. From 1958 to 2003 the chemocline descended 1.1 m and the volume of the monimolimnion from 698,000 m3 to 114,000 m3. Annual loss of volume is occurring at a rate of 1.9% since 1958. Although groundwater interception wells are maintaining the volume of the entire lake, the recession of the chemocline indicates that conditions that have maintained meromixis at Soap Lake are currently not in equilibrium. 相似文献
Semi-continuous and 24-h averaged measurements of fine carbonaceous aerosols were made concurrently at three sites within each of two U.S. Midwestern Cities; Detroit, Michigan and Cleveland, Ohio; during two, one-month intensive campaigns conducted in July of 2007 and January & February of 2008. A comparison of 24-h measurements revealed substantial intra-urban variability in carbonaceous aerosols consistent with the influence of local sources, and excesses in both PM2.5 organic carbon (OC) and elemental carbon (EC) were identified at individual sites within each city. High time-resolved black carbon (BC) measurements indicated that elemental carbon concentrations were higher at sites adjacent to freeways and busy surface streets, and temporal patterns suggested that excess EC at sites adjacent to freeways was dominated by mobile source emissions while excesses in EC away from traffic corridors was dominated by point/area source emissions. The site-to-site variability in OC concentrations was approximately 7% within the neighborhood scale (0.5–4 km) and between 4 and 27% at the urban scale (4–100 km). In contrast, measurements of organic source tracers, in conjunction with a Chemical Mass Balance (CMB) source-apportionment model, indicated that the spatial variation in the contribution of both mobile and stationary sources to PM2.5 OC often exceeded the variation in OC mass concentration by a factor of 3 or more. Markers for mobile sources, biomass smoke, natural gas, and coal combustion differed by as much as 60% within the neighborhood scale and by greater than 200% within the urban scale. The observations made during this study suggest that the urban excess of carbonaceous aerosols is much more complex than has been previously reported and that a more rigorous, source-oriented approach should be taken in order to assess the risk associated with exposure to carbonaceous aerosols within the industrialized environments of the Midwestern United States. 相似文献