排序方式: 共有64条查询结果,搜索用时 62 毫秒
41.
Bussotti F Gerosa G Cenni E Cozzi A Ferretti M Bettini D Nibbi R 《Environmental monitoring and assessment》2003,85(3):221-238
This study examines defoliation and discoloration findings collected throughout the Italian Level I network between 1997 and 2000. Prior to this period no Quality Assurance procedures had been implemented, so that earlier findings cannot be considered reliable. The aim of the study is to compare differentindices used in reporting findings, in order to determine the full potential and limitations of each. In international surveys,findings are normally expressed in terms of individual trees presenting a defoliation level greater than 2 %; this criterion,however, has been challenged since it is not based on scientificevidence. By analysing the distribution of defoliation values(grouped in 5% classes) relating to the main species (Fagus sylvatica, Quercus pubescens, Quercus cerris, Picea abies), the study examines the behaviour of statistical indices such as the median, the mode and the mean. Instead of using the traditional 25% threshold to determine the part of the population with the highest defoliation values, a procedureis suggested whereby a different threshold can be determined foreach species. It is established based on the 90° percentile of cumulative defoliation values recorded over the four-year period. Each index used to report findings possessesits own information potential, and the findings may at times appear contradictory. The use of a combined defoliation and discoloration index (Ilce = Lacking Crown Equivalent Index) is also proposed, but the results obtained do not differin substance from the results relating to defoliation alone. Thefunctional limitations of this index are due mainly to the way the data are collected: for this reason suggestions are made onhow to improve the procedure in future surveys. 相似文献
42.
43.
Air pollutants and the characterization of the organic content of aerosol particles in a mixed industrial/semi-rural area in central Italy 总被引:1,自引:0,他引:1
Di Filippo P Riccardi C Gariazzo C Incoronato F Pomata D Spicaglia S Cecinato A 《Journal of environmental monitoring : JEM》2007,9(3):275-282
Both regulated and unregulated air pollutants were detected during an intensive seasonal sampling campaign in a mixed industrial/semi-rural area on the outskirts of Rome, Italy, at two sites located opposite a hospital waste incinerator, downwind according to the direction of the prevailing local winds. Concentrations of pollutants were significantly lower than in urban atmospheres. The composition of particulate organic material indicated a heavy biogenic impact, accompanied by a lower contribution from petroleum-related processes. Both PAH and nitro-PAH group compositions of particulates were used to assess the nature and relative importance of sources. Both sites showed that different and diffuse sources contributed to local pollution with a significant contribution from traffic, proving that the hospital waste incinerator was not the main pollution source in this area. Among unregulated compounds, a series of positional isomers of nitro-PAHs and other organic compounds associated with particulate matter were investigated. In particular, 1- and 3-nitrophenanthrene identification was carried out, and they proved to be the most abundant nitro-PAHs. 相似文献
44.
Gerosa G Ferretti M Bussotti F Rocchini D 《Environmental pollution (Barking, Essex : 1987)》2007,145(3):629-635
Weekly-fortnightly ozone (O3) concentrations measured by passive sampling at 81 forest monitoring plots in France, Italy, Spain and Switzerland over the period 2000-2002 were used to estimate the cumulative exposure index AOT40. The estimation method is based on a deterministic model which describes the O3 daily profile as a function of relative altitude (the difference between the altitude of the site and the lowest altitude within a 5 km radius) and the time of the day. Estimated AOT40 values (AOT40(e)) were evaluated against co-located automatic measurement stations and with 14 independent automatic stations located throughout Italy whose weekly mean O3 values were used to simulate passive samplers. AOT40 can be predicted by modelling passive sampling data (R2: 0.90; P<0.0001, SE of estimates: 3271 ppb h), although considerable deviations can occur for individual sites. Estimated AOT40 shows a distinct, significant latitudinal and altitudinal gradient. Taking the 3-year average as a whole, exceedance of critical level of 5000 ppb h occurs at 77-100% of the monitored sites, respectively. 相似文献
45.
Filippo Gavelli 《Journal of Loss Prevention in the Process Industries》2010,23(6):773-780
Ambient air vaporizers (AAVs) are widely used to regasify liquefied industrial gases, which are liquefied for transport and storage. Depending on the conditions (temperature and relative humidity) of ambient air and AAV effluent, the potential exists for the formation of fog as the two fluids mix with each other. This has raised some regulatory and environmental concerns that the fog cloud may impact human activities in the vicinity of the AAV arrays.This paper describes a CFD-based modeling approach to predict the formation, dispersion and dissipation of a fog cloud due to AAV operation. The model uses the psychrometrics equations to determine when saturated air conditions are reached and to calculate mass and energy transfer between the moist air and the fog cloud. A parametric study is presented, based on an array of 6 AAVs, to demonstrate the effects of wind speed and AAV discharge elevation on the behavior of the fog cloud. 相似文献
46.
Delia Cavallo Cinzia L. Ursini Patrizia Di Filippo Aureliano Ciervo Sergio Spicaglia Donatella Pomata Federica Incoronato Sergio Iavicoli 《Water, Air, & Soil Pollution: Focus》2009,9(1-2):69-77
Airborne particulate matter (PM) extracts were investigated for their content of organic compounds and for the direct and oxidative DNA damage induced on lung epithelial cells A549. PM10 was seasonally collected at two monitoring sites (Stations 1 and 2), characterized by different traffic loads. The cells were exposed for 30 min to extracts of PM10 diluted at 0.025%, 0.05%, and 0.1% for summer samples, and at 0.05%, 0.1%, and 0.15% for winter samples. Oxidative and direct DNA damage were evaluated by formamidopyrimidine glycosylase (fpg) comet assay analyzing tail moment (TM) values from fpg-enzyme-treated cells (TMenz) and enzyme untreated cells (TM) respectively and by comet percentage analysis. Measurements relating to Station 2 showed higher levels of polycyclic aromatic hydrocarbons (PAHs), and their methyl-(methyl-PAHs) and nitro-(nitro-PAHs) derivatives in both the seasons. Nitro-PAH concentrations were higher in summer than in winter at both the stations. We found a significant increase of comet percentages at the highest dose of extract from both stations in summer and from Station 2 in winter. The TM and TMenz values relative to the summer sampling showed an early oxidative DNA damage induction also followed by direct DNA damage more evident at Station 2, that seems to correlate with the presence of higher nitro-PAH concentrations during the warm season. At both monitoring stations, the results from winter sampling campaign showed a direct DNA damage induction at 0.1% of extract and oxidative-direct DNA damage at the highest dose (0.15%). 相似文献
47.
Filippo Gavelli Melissa K. Chernovsky Edward Bullister Harri K. Kytomaa 《Journal of Loss Prevention in the Process Industries》2009,22(6):809-819
The use of computational fluid dynamics (CFD) models to simulate LNG vapor dispersion scenarios has been growing steadily over the last few years, with applications to LNG spills on land as well as on water. Before a CFD model may be used to predict the vapor dispersion hazard distances for a hypothetical LNG spill scenario, it is necessary for the model to be validated with respect to relevant experimental data. As part of a joint-industry project aimed at validating the CFD methodology, the LNG vapor source term, including the turbulence level associated with the evaporation process vapors was quantified for one of the Falcon tests.This paper presents the method that was used to quantify the turbulent intensity of evaporating LNG, by analyzing the video images of one of the Falcon tests, which involved LNG spills onto a water pond. The measured rate of LNG pool growth and spreading and the quantified turbulence intensity that were obtained from the image analysis were used as the LNG vapor source term in the CFD model to simulate the Falcon-1 LNG spill test. Several CFD simulations were performed, using a vaporization flux of 0.127 kg/m2 s, radial and outward spreading velocities of 1.53 and 0.55 m/s respectively, and a range of turbulence kinetic energy values between 2.9 and 28.8 m2/s2. The resulting growth and spread of the vapor cloud within the impounded area and outside of it were found to match the observed behavior and the experimental measured data.The results of the analysis presented in this paper demonstrate that a detailed and accurate definition of the LNG vapor source term is critical in order for any vapor cloud dispersion simulation to provide useful and reliable results. 相似文献
48.
Filippo Randelli 《Regional Environmental Change》2009,9(3):221-229
Up to now, the “low” price of oil has prevented the development of alternative fuels but with the current high price and increasing
scarcity, biofuels could become an economically attractive alternative. However, the economic assessment of biofuels has to
take into account total production costs, including impact on agriculture, and the energy balance of first generation alternative
fuels (biodiesel and bioethanol). Moreover, plans to produce biofuels from agriculture should not be achieved without considering
the latest developments and reforms of the common agricultural policy, which promotes a change towards sustainable rural development
based on multifunctional agriculture. From the analysis carried out, it emerges that first generation biofuels do not seem
to be the best solution because of high production cost, limited land availability and low net energy balance. Furthermore,
only a small quantity of biofuels can be produced as alternative to fossil oil because an incremental production will lead
to the rising of agri-food prices. Only second generation biofuels could be a possible solution, although they still require
much supplementary research and analysis. 相似文献
49.
50.
Gerosa G Marzuoli R Bussotti F Pancrazi M Ballarin-Denti A 《Environmental pollution (Barking, Essex : 1987)》2003,125(1):91-98
During the summer of 2001, 2-year-old Fraxinus excelsior and Fagus sylvatica plants were subjected to ozone-rich environmental conditions at the Regional Forest Nursery at Curno (Northern Italy). Atmospheric ozone concentrations and stomatal conductance were measured, in order to calculate the foliar fluxes by means of a one-dimensional model. The foliar structure of both species was examined (thickness of the lamina and of the individual tissues, leaf mass per area, leaf density) and chlorophyll a fluorescence was determined as a response parameter. Stomatal conductance was always greater in Fraxinus excelsior, as was ozone uptake, although the highest absorption peaks did not match the peaks of ozone concentration in the atmosphere. The foliar structure can help explain this phenomenon: Fraxinus excelsior has a thicker mesophyll than Fagus sylvatica (indicating a greater photosynthesis potential) and a reduced foliar density. This last parameter, related to the apoplastic fraction, suggests a greater ability to disseminate the gases within the leaf as well as a greater potential detoxifying capacity. As foliar symptoms spread, the parameters relating to chlorophyll a fluorescence also change. PI (Performance Index, Strasser, A., Srivastava, A., Tsimilli-Michael, M., 2000. The fluorescence transient as a tool to characterize and screen photosynthetic samples. In: Yunus, M., Pathre, U., Mohanty, P., (Eds.) Probing Photosynthesis: Mechanisms, Regulation and Adaptation. Taylor & Francis, London, UK, pp. 445-483.) has proved to be a more suitable index than Fv/Fm (Quantum Yield Efficiency) to record the onset of stress conditions. 相似文献