首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   1篇
  国内免费   1篇
废物处理   1篇
环保管理   1篇
综合类   4篇
基础理论   1篇
污染及防治   25篇
评价与监测   1篇
社会与环境   1篇
  2017年   1篇
  2014年   2篇
  2013年   3篇
  2012年   1篇
  2011年   3篇
  2010年   2篇
  2009年   2篇
  2008年   2篇
  2007年   4篇
  2006年   4篇
  2005年   3篇
  2004年   4篇
  2003年   1篇
  2002年   1篇
  1990年   1篇
排序方式: 共有34条查询结果,搜索用时 727 毫秒
11.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   
12.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   
13.
Wang LC  Lee WJ  Tsai PJ  Lee WS  Chang-Chien GP 《Chemosphere》2003,50(9):1123-1129
This study investigated four sinter plants, classified into two categories--with selective catalytic reduction (SCR) (S1, S2 and S3) and without SCR (S4) as its air pollution control device. Polychlorinated dibenzofurans (PCDFs) are dominant in the stack flue gases of sinter plants with and without SCR. The polychlorinated dibenzofurans/polychlorinated dibenzo-p-dioxins (PCDFs/PCDDs) ratio exceeds 1 extremely. The degree of chlorination of the sinter plant without SCR is towards hepta and hexa congeners while that of the sinter plant with SCR is towards penta and hexa congeners. PCDD/Fs are indeed decomposed (75.5% and 69% on ng and ng TEQ bases, respectively) and not only reduced in degree of chlorination. The overall concentration in the stack flue gas of sinter plants with SCR (7.97-14.1 ng/Nm(3); 0.995-2.06 ng TEQ/Nm(3)) is lower than that of the sinter plant without SCR (28.9 ng/Nm(3); 3.10 ng TEQ/Nm(3)). In Taiwan, based on the emission factors of 0.970 microg TEQ/ton-feedstock (sinter plants with SCR) and 3.13 microg TEQ/ton-feedstock (sinter plant without SCR), the annual PCDD/F emission of 44.7 g TEQ/year from sinter plants is 60 and 121 times higher than those from municipal solid waste incinerators (0.750 g TEQ/year) and MWIs (0.369 g TEQ/year). These results show that sinter plants have become the dominating PCDD/F emission source since tighter emission limits have been applied to incinerators.  相似文献   
14.

Background and purpose

China's environmental problems and pollution control have global implications. China??s water pollution has been increasing with its urbanization and industrialization. Although great efforts have been taken to keep its wastewater discharge standards in pace with the water pollution development and technological advances, many challenges remain. A summary of the past achievements and lessons as well as the current problems in water pollution may provide a basis for future improvements in China and a reference for other countries.

Methods

Statistical data are summarized to reveal the evolution of China??s population, wastewater discharge and corresponding discharge standards over the past four decades. In particular, the specific control indexes and number of controlled items are discussed in details. The present water pollution situation is clearly illustrated by the water pollution map and the water quality distribution diagram. A comparison between China??s present wastewater discharge standards and those in the USA and the EU are also presented to find the possibilities for future improvement.

Results

The historical origins, major challenges and future perspectives of China??s wastewater discharge standards are overviewed. The barriers and ongoing efforts for standards formulation and implementation are highlighted. Some suggestions for future endeavors are given.

Conclusions

China??s wastewater discharge standard system has seen significant improvement over the past decades, but it still has many defects and limitations. Nonetheless, unprecedented great efforts are underway to address all these challenges. More stringent standards and subsequently a cleaner water environment in China can be expected in the near future.  相似文献   
15.
The particle size distributions and leaching characteristics of polybrominated diphenyl ethers (PBDEs) in the bottom ashes of two Taiwanese municipal solid waste incinerators (MSWIs A and B) were investigated to evaluate PBDE leaching into the environment through reutilization of bottom ashes. The PBDE contents in the bottom ashes of the MSWIs (29.0–243 ng/g) could be two orders higher than those in rural and urban soils. The PBDE fraction of the bottom ashes was more distributed in larger particles (> 0.25 mm). Similar trends were found for the PBDE contents in the bottom ashes and their PBDE leaching concentrations, revealing that the elevated PBDE contents in the bottom ashes may lead to a higher PBDE leaching mass. The leaching of PBDEs is attributed to diffusion driven by the concentration gradient and effective surface area. The normalized leaching ratios (NLRs) of PBDEs for the bottom ashes of the MSWIs are about four orders greater than those of PBDE-related raw materials and products, and this may be due to their porous structures having much greater effective surface area. The elevated NLRs of PBDEs thus deserve more attention when bottom ashes are recycled and reutilized as construction materials.  相似文献   
16.
This study was set out to assess polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) exposures and health-risk impact posed on sinter plant workers. One sinter plant located in southern Taiwan was selected and their workers were divided into four exposure groups based on their work tasks, including raw material charging workers, sintering grate workers, shredding workers, and others. Results show that their mean total PCDD/F and the corresponding total I-TEQ exposure levels shared the same trend as: shredding workers>others>sintering grate workers>raw material charging workers. For all selected exposure groups, their PCDD/F exposures were dominated by the particle phase contents. Congener profiles of the gaseous+particle phase PCDD/Fs were found with more fractions of high chlorinated congeners than low chlorinated congeners. The lifetime average daily doses (LADDs) and their resultant excess cancer risks (ECRs) found for sinter plant workers were higher than those residents living at the residential area and rural area, but were lower than those living at the nearby of the selected sinter plant, urban area, industrial area. Considering ECRs of the sinter plant workers were still higher than 10(-6) suggesting the need for adopting proper control measurements for reducing workers' PCDD/F exposures, particularly for those sinter zone workers.  相似文献   
17.
Wu FB  Chen F  Wei K  Zhang GP 《Chemosphere》2004,57(6):447-454
Hydroponic experiment was carried out to study the effect of three Cd levels on glutathione (GSH), free amino acids (FAA), and ascorbic acid (ASA) concentration in the different tissues of 2 barley cultivars with different Cd tolerance. Cadmium concentration in both roots and shoots increased with external Cd level, while biomass and ASA concentration declined, and Wumaoliuling, a Cd-sensitive genotype was more affected than ZAU 3, a Cd-tolerant genotype. The effect of Cd on GSH concentration was dose- and time-dependent. In the 5 d exposure, root GSH concentration increased in 0.5 microM Cd treatment compared with control, but decreased significantly in 5 microM Cd treatment, irrespective of genotypes. However, in the 10 d exposure, GSH concentration in all plant tissues decreased with increasing Cd levels in the culture medium, and Wumaoliuling was much more affected than ZAU 3. Cadmium treatment greatly altered FAA concentration and composition in plants. The effect of Cd on glutathione (Glu) concentration in roots varied with genotypes. ZAU 3 showed a steady increase in root Glu concentration in both 0.5 and 5 microM Cd treatments, while Wumaoliuling was decreased by 38.0% in 5 microM Cd treatment, compared with the control. The results indicate that GSH and ASA are attributed to Cd tolerance in barley plants, and the relative less reduction in GSH concentration in ZAU 3 under Cd stress relative to the control may account for its higher Cd tolerance.  相似文献   
18.
高浓度发酵废水的生物处理及资源化利用研究进展   总被引:2,自引:1,他引:1  
文章对糖蜜酒精、抗生素发酵生产过程废水厌氧、好氧等生物处理技术及其农业、工业方面的资源化利用现状进行了综述.结合本实验室近期的研究进展,着重介绍了国内外糖蜜废水的利用状况.指出了结合资源化利用的废水处理生物技术是未来的发展趋势,在经济、高效地转化高浓度有机废水为资源性产品的应用中前景广阔.  相似文献   
19.
Lin LF  Lee WJ  Li HW  Wang MS  Chang-Chien GP 《Chemosphere》2007,68(9):1642-1649
The objectives of the present study were to quantify (1) the emission factors of a variety of dioxin emission sources; (2) the overall dioxin emission inventory in Taiwan as well as in a major metropolitan (KC area); and (3) the contribution of power plants to the overall PCDD/F emission. To achieve these goals, a total of 95 flue gas samples were collected and analyzed for 17 PCDD/Fs from 20 sources to develop emission factors. The emission factor of PCDD/Fs from coal-fired power plants (0.62 microgI-TEQton(-1)) obtained in this study is considerably higher than the values reported from different countries including UK, USA, and Spain by a factor of 2-265. It means that the air pollution control devices in certain power plants need to be more efficient. The emission data showed that there is a total annual release to air of 6.1 and 95gI-TEQ from major sources in the KC area and Taiwan, respectively. The dominant sources of PCDD/Fs in the KC area are the coal-fired power plants, secondary aluminum smelting, electric arc furnaces, and open burning of rice straw, which contributed for 56%, 17%, 13%, and 3.3% to the total, respectively. However, in Taiwan, the dominant sources of PCDD/Fs are the iron ore sintering, coal-fired power plants, electric arc furnaces, and open burning of rice straw, which contributed for 32%, 28%, 23%, and 8.1% to the total, respectively. The results of this study showed that coal-fired power plants are very significant sources of PCDD/Fs and also provide an important database to assist the decision makers for formulating policies to alleviate dioxin concerns.  相似文献   
20.
To understand the fate of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in a fly ash treatment plant that used the Waelz rotary kiln process (hereafter the Waelz process), the samples of input and output media were collected and analyzed. The most important PCDD/F source in input mass was electric arc furnace (EAF) fly ash, which had a mean PCDD/F content of 18.51 ng/g and contributed more than 99% of PCDD/F input mass, whereas the PCDD/F input mass fractions contributed by the coke, sand, and ambient air were only 0.04%, 0.02%, and 0.000002%, respectively. For the PCDD/F output mass in the Waelz process, the major total PCDD/F contents of 43.73 and 10.78 ng/g were in bag-filter and cyclone ashes, which accounted for approximately 69% and 17%, respectively, whereas those of stack flue gas and slag were 14% and 0.423%, respectively. The Waelz process has a dechlorination mechanism for higher chlorinated congeners, but it is difficult to decompose the aromatic rings of PCDD/Fs. Therefore, this resulted in the accumulation of lower chlorinated congeners. The output/input ratio of total PCDD/F mass and total PCDD/F international toxicity equivalence (I-TEQ) was 0.62 and 1.19, respectively. Thus, the Waelz process for the depletion effect of total PCDD/F mass was positive but minor, whereas the effect for total PCDD/F I-TEQ was adverse overall.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号