Oil contamination has become a primary environmental concern due to increased exploration, production, and use. When oil enters the soil, it may attach or adsorb to soil particles and stay in the soil for an extended period, contaminating the soil and surrounding areas. Nanoparticles have been widely used for the treatment of organic pollutants in the soil. Surfactant foam has effectively been employed to remediate various soil contaminants or recover oil compounds. In this research, a mixture of biosurfactant foam/nanoparticle was utilized for remediation of oil-contaminated soil. The results demonstrated that the biosurfactant/nanoparticle mixture and nitrogen gas formed high-quality and stable foams. The foam stability depended on the foam quality, biosurfactant concentration, and nanoparticle dosage. The pressure gradient change in the soil column relied on the flowrate (N2 gas + surfactant/nanoparticle mixture), foam quality, and biosurfactant concentration. The optimal conditions to obtain good quality and stable foams and high oil removal efficiency involved 1 vol% rhamnolipid, 1 wt% nanoparticle, and 1 mL/min flowrate. Biosurfactant foam/nanoparticle mixture was effectively used to remediate oil-contaminated soil, whereas the highest treatment efficiency was 67%, 59%, and 52% for rhamnolipid biosurfactant foam/nanoparticle, rhamnolipid biosurfactant/nanoparticle, and only rhamnolipid biosurfactant, respectively. The oil removal productivity decreased with the increase of flowrate due to the shorter contact time between the foam mixture and oil droplets. The breakthrough curves of oil pollutants in the soil column also suggested that the foam mixture’s maximum oil treatment efficiency was higher than biosurfactant/nanoparticle suspension and only biosurfactant.
Various clean-up technologies have been developed for the removal and/or destruction of trichloroethene (TCE) in the subsurface. Surfactant-aided soil washing followed by photodegradation could be a promising approach to such a task. The modelling of TCE photodegradation by UV in Brij 35 surfactant micelles is therefore investigated. Two stages of TCE degradation are observed in surfactant Brij 35 systems. A lag phase is observed at the commencement of the degradation, but the duration of the lag phase is significantly reduced as the initial pH increases. As the overall decay of TCE is also found to be faster at higher pH levels, it is suggested that the free radical reaction is dominant at high pH levels, and the formation of lag phases is mainly due to the deficiency of free radicals at lower pH levels. Since the period of the lag phase gradually decreases with the increase of initial pH level, and the two pseudo first-order reaction constants (one for the lag phase and one for the subsequent fast decay) for TCE decay in both stages are also pH dependent, a non-steady-state mathematical model is developed for the prediction of TCE photodegradation in Brij 35 solutions, in which the remaining fraction of TCE (C/C0) in the system can be determined at any instant by using a simple parameter of the initial system pH. 相似文献
A microbubble ozonation process for enhancing sludge solubilization was proposed and its performance was evaluated in comparison to a conventional ozone bubble contactor. Microbubbles are defined as bubbles with diameters less than several tens of micrometers. Previous studies have demonstrated that microbubbles could accelerate the formation of hydroxyl radicals and hence improve the ozonation of dyestuff wastewater. The results of this study showed that microbubble ozonation was effective in increasing ozone utilization and improving sludge solubilization. For a contact time of 80 min, an ozone utilization efficiency of more than 99% was obtained using the microbubble system, while it gradually decreased from 94% to 72% for the bubble contactor. The rate of microbial inactivation was obviously faster in the microbubble system. At an ozone dose of 0.02 g O3 g−1 TSS, about 80% of microorganisms were inactivated in the microbubble system, compared with about 50% inactivation for the bubble contactor. Compared to the bubble contactor, more than two times of COD and total nitrogen, and eight times of total phosphorus content were released from the sludge into the supernatant by using the microbubble system at the same ozone dosage. The application of microbubble technology in ozonation processes may provide an effective and low cost approach for sludge reduction. 相似文献
The purpose of this study was to conduct a field study at a Florida field site on surface emissions and subsurface distribution of cis-and trans-1,3-dichloropropene (1,3-D) and chloropicrin (CP) in raised beds injected with Telone C35 with four replications. A total of 16 beds were applied with Telone C35 by chisel injection and covered with four different plastic films, 4 beds for each film. Each bed was installed with five 20-cm long soil pore air probes and a surface air collection pan at arbitrarily locations along the length of each bed for sampling soil pore air and surface air, respectively, for analysis of the three biologically active compounds, cis- and trans-1,3-D and CP. We found that average concentrations of the three compounds at 20-cm depth among the beds covered with four different plastic films generally were not statistically different. Among the four beds covered with the same plastic film, average concentrations of the three compounds were statistically different only in the four metallic PE covered beds at 5 and 24 hours after injection. Volatilization rates of the three compounds among the beds covered with four different plastic films, with the exception of CP at 48 hours after injection, were not statistically different. It appeared that initial upward diffusion and volatilization flux were influenced by solar radiation. Initial subsurface concentrations of the three compounds and volatilization flux, especially cis-1,3-D, were greater in the beds on the east side of the field than that in the beds on the west side of the field. Whether or not difference in initial subsurface concentrations of the compounds between east side beds and west side beds may influence fumigant efficacy remains to be determined. 相似文献
Heat stress on workers working outdoors in the power industry may result in fatigue and deterioration in task performance. This research collected and analyzed data on task performance of workers working indoors and outdoors with and without a cooling suit. The task performance was compared on the basis of heart rate, oxygen consumption, tympanic temperature, subjective responses, productivity, and error rates. Based on One-Way Analysis Of Variance (ANOVA) results, a significantly lower estimated working oxygen consumption was observed (p < .001) when the cooling suit was worn. The productivity was higher while workers wore the cooling suit as compared to no cooling suit (p = .011) whereas the error rates were significantly lower (p < .001). Also a significantly lower self-reported discomfort was observed in the neck and shoulders while working wearing the cooling suit (p = .004). This study concluded that wearing a cooling suit while working outdoors was associated with physiological benefits as well as improved task performance of the study participants. 相似文献
Landfill leachates were collected and their chemical properties analyzed once every two months over a ten-month period from
the Gin Drinkers' Bay (GDB) and Junk Bay (JB) landfills. The contents of solids, and inorganic and organic components fluctuated
considerably with time. In general, the chemical properties of the two leachates correlated negatively (P<0.05) with the amounts of rainfall prior to the sampling periods. However, magnesium and pH of the leachates remained relatively
constant with respect to sampling time. The JB leachate contained higher average contents of solids and inorganic and organic
matter than those of GDB with the exception of trace metals. Trace metals were present in the two leachates in trace quantities
(<1.0 mg/liter). The concentrations of average ammoniacal nitrogen were 1040 and 549 mg/liter, while chemical oxygen demand
(COD) values were 767 and 695 mg/liter for JB and GDB leachates, respectively. These results suggest that the leachates need
further treatment before they can be discharged to the coastal waters. 相似文献
According to the practice researching and formulating “The Oil Spill Contingency Plan of south Chinese Sea”,this paper analyses and discusses the structure,functions and main contents of marine oil spill contingency planning,programs the organizing and commanding system and emergency response system,and advances the planning and researching method to coordinate comprehensively and to design practically the detailed emergency response steps until to formulate the ease operating programs for the plan implementation(PPI) and the PPI to apply high-techniques supporting emergency administrations and response. 相似文献