排序方式: 共有60条查询结果,搜索用时 15 毫秒
31.
Benkdad A Laissaoui A Tornero MV Benmansour M Chakir E Garrido IM Moreno JB 《Environmental monitoring and assessment》2011,182(1-4):317-324
Macroalgae species Codium sp, Bangia atropurpurea, Membranoptera alata, Plocamium cartilagineum, Dictyota dichotoma, Fucus spiralis and Stypocaulon scoparia were collected from seven stations along the north coast of Morocco. Samples were analysed to determine activities of naturally occurring radionuclides ((210)Pb, U isotopes and (40)K) and concentrations of metals (Zn, Fe, Co, Cu, Ni, Mn, Pb, Cd, As and Cr) using radiometric and ICP-OES techniques, respectively. Metal concentrations were within ranges reported in the scientific literature, and concentrations of bio-essential elements were in the order Mn>Fe> Zn>Cu in all samples. Brown algae had the highest concentrations of almost all metals, and concentrations decreased in the order brown>red>green algae. With respect to radionuclides, the red alga P. cartilagineum had the highest activities of (210)Pb, in most cases an order of magnitude higher than for the green alga Codium sp. (234)U and (238)U activities in all algae samples were in the range 0.96- 7.61 and 1.16-6.14 Bq/kg dry weight, respectively. Our analyses of radionuclide activities and metal concentrations in marine macroalgae showed large differences among taxa. These results provide insights into which algal species should be used for biomonitoring programmes. 相似文献
32.
Garrido Isabel Fenoll José Flores Pilar Hellín Pilar Pérez-Lucas Gabriel Navarro Simón 《Environmental science and pollution research international》2021,28(19):23647-23656
Environmental Science and Pollution Research - One of the consequences of phytosanitary treatments applied to crops is the generation of a great volume of agro-wastewater having pesticide residues.... 相似文献
33.
34.
There is a necessity for improved physical understanding of solute transport processes in heterogeneous soil systems. In situ nondestructive techniques like time domain reflectometry (TDR) and fiber optic miniprobes (FOMPs) permit the collection of unique measurements of solute transport processes in soils for the purposes of model development and validation. This study examined the application of TDR and FOMPs to measure solute transport at various points laterally and at two depths in a heterogeneous clay-loam soil. A miscible displacement experiment was performed at a constant irrigation flux to examine the applicability of these probes to field soils. In their first application to a field soil, the FOMPs were successfully calibrated and performed well in measuring solute breakthrough curves. Two flow regimes were identified in the soil profile, the first where lateral spreading of the solute occurred in the surface horizon, followed by convergence into preferential flow pathways in the second transport zone. The measured transport response was heterogeneous with at least two identifiable vertical flow phases. It was demonstrated using transfer function modeling and data from a corresponding laboratory study that the FOMPs were measuring the slower phase, while the TDR probes captured a composite of the fast and slow phases. The combination of these two techniques may be a means to separate solute transport phases in heterogeneous media and relate laboratory column results to field studies. 相似文献
35.
36.
Application of water quality indices and analysis of the surface water quality monitoring network in semiarid North-Central Chile 总被引:4,自引:0,他引:4
Espejo L Kretschmer N Oyarzún J Meza F Núñez J Maturana H Soto G Oyarzo P Garrido M Suckel F Amezaga J Oyarzún R 《Environmental monitoring and assessment》2012,184(9):5571-5588
Surface water quality has increasing importance worldwide and is particularly relevant in the semiarid North-Central Chile, where agriculture and mining activities are imposing heavy pressure on limited water resources. The current study presents the application of a water quality index in four watersheds of the 29°-33°S realm for the period 1999-2008, based on the Canadian Council of Ministers for the Environment approach and the Chilean regulation for irrigation water quality. In addition, two modifications to the index are tested and a comprehensive characterization of the existing monitoring network is performed through cluster analysis. The basins studied show fairly good water quality in the overall, specially the Limarí basin. On the other hand, the lower index values were obtained for the headwaters of Elqui, associated with the El Indio mining district. The first modification of the indicator (i.e., to consider parameters differentially according to their effect on human health or the environment) did not produce major differences with respect to the original index, given the generally good water quality. The second modification (i.e., to consider as threshold values the more restrictive figures derived from a set of regulations) yielded important differences in the indicator values. Finally, an adequate characterization of the monitoring network was obtained. The results presented spatial coherence and the information can be used as a basis for the optimization of the monitoring network if required. 相似文献
37.
El-Ghenymy A Arias C Cabot PL Centellas F Garrido JA Rodríguez RM Brillas E 《Chemosphere》2012,87(10):1126-1133
38.
39.
Degradation of clofibric acid in acidic aqueous medium by electro-Fenton and photoelectro-Fenton 总被引:2,自引:0,他引:2
Sirés I Arias C Cabot PL Centellas F Garrido JA Rodríguez RM Brillas E 《Chemosphere》2007,66(9):1660-1669
Acidic aqueous solutions of clofibric acid (2-(4-chlorophenoxy)-2-methylpropionic acid), the bioactive metabolite of various lipid-regulating drugs, have been degraded by indirect electrooxidation methods such as electro-Fenton and photoelectro-Fenton with Fe(2+) as catalyst using an undivided electrolytic cell with a Pt anode and an O(2)-diffusion cathode able to electrogenerate H(2)O(2). At pH 3.0 about 80% of mineralization is achieved with the electro-Fenton method due to the efficient production of oxidant hydroxyl radical from Fenton's reaction between Fe(2+) and H(2)O(2), but stable Fe(3+) complexes are formed. The photoelectro-Fenton method favors the photodecomposition of these species under UVA irradiation, reaching more than 96% of decontamination. The mineralization current efficiency increases with rising metabolite concentration up to saturation and with decreasing current density. The photoelectro-Fenton method is then viable for treating acidic wastewaters containing this pollutant. Comparative degradation by anodic oxidation (without Fe(2+)) yields poor decontamination. Chloride ion is released during all degradation processes. The decay kinetics of clofibric acid always follows a pseudo-first-order reaction, with a similar rate constant in electro-Fenton and photoelectro-Fenton that increases with rising current density, but decreases at greater metabolite concentration. 4-Chlorophenol, 4-chlorocatechol, 4-chlororesorcinol, hydroquinone, p-benzoquinone and 1,2,4-benzenetriol, along with carboxylic acids such as 2-hydroxyisobutyric, tartronic, maleic, fumaric, formic and oxalic, are detected as intermediates. The ultimate product is oxalic acid, which forms very stable Fe(3+)-oxalato complexes under electro-Fenton conditions. These complexes are efficiently photodecarboxylated in photoelectro-Fenton under the action of UVA light. 相似文献
40.
Degradation of the herbicide 2,4-DP by anodic oxidation, electro-Fenton and photoelectro-Fenton using platinum and boron-doped diamond anodes 总被引:1,自引:0,他引:1
This paper reports the degradation of 2,4-DP (2-(2,4-dichlorophenoxy)-propionic acid) solutions of pH 3.0 by environmentally friendly electrochemical methods such as anodic oxidation, electro-Fenton and photoelectro-Fenton with a Pt or boron-doped diamond (BDD) anode. In the two latter techniques an O(2)-diffusion cathode was used and 1.0mM Fe(2+) was added to the solution to give hydroxyl radical (*OH) from Fenton's reaction between Fe(2+) and H(2)O(2) generated at the cathode. All treatments with BDD are viable to decontaminate acidic wastewaters containing 2,4-DP since they give complete mineralization, with loss of chloride ion, at high current due to the great production of oxidant *OH at the BDD surface favoring the destruction of final carboxylic acids. *OH formed from Fenton's reaction destroys more rapidly aromatic products, making the electro-Fenton and photoelectro-Fenton processes much more efficient than anodic oxidation. UVA light in photoelectro-Fenton with BDD has little effect on the degradation rate of pollutants. The comparative procedures with Pt lead to slower decontamination because of the lower oxidizing power of this anode. The effect of current on the degradation rate and efficiency of all methods is studied. The 2,4-DP decay always follows a pseudo-first-order kinetics. Chlorohydroquinone, chloro-p-benzoquinone and maleic, fumaric, malic, lactic, pyruvic, acetic, formic and oxalic acids are detected as products by chromatographic techniques. A general sequence accounting for by the reaction of all these intermediates with the different oxidizing agents is proposed. 相似文献