全文获取类型
收费全文 | 166篇 |
免费 | 4篇 |
国内免费 | 2篇 |
专业分类
安全科学 | 7篇 |
废物处理 | 20篇 |
环保管理 | 14篇 |
综合类 | 11篇 |
基础理论 | 30篇 |
环境理论 | 1篇 |
污染及防治 | 38篇 |
评价与监测 | 31篇 |
社会与环境 | 19篇 |
灾害及防治 | 1篇 |
出版年
2023年 | 4篇 |
2022年 | 21篇 |
2021年 | 22篇 |
2020年 | 4篇 |
2019年 | 6篇 |
2018年 | 12篇 |
2017年 | 9篇 |
2016年 | 16篇 |
2015年 | 10篇 |
2014年 | 6篇 |
2013年 | 25篇 |
2012年 | 8篇 |
2011年 | 9篇 |
2010年 | 4篇 |
2009年 | 5篇 |
2008年 | 3篇 |
2007年 | 1篇 |
2006年 | 2篇 |
2005年 | 1篇 |
2004年 | 1篇 |
1989年 | 1篇 |
1986年 | 1篇 |
1985年 | 1篇 |
排序方式: 共有172条查询结果,搜索用时 15 毫秒
41.
Mikhak Hossein Rahimian Mehdi Gholamrezai Saeed 《Environment, Development and Sustainability》2022,24(8):9833-9850
Environment, Development and Sustainability - In this research, 17 implications of changing cropping patterns (CP) to low water demand plants (LWDPs) were identified. Then, the experts were asked... 相似文献
42.
Hadi Hajizadeh Namaghi Gholam Hossein Karami Saeed Saadat 《Environmental monitoring and assessment》2011,174(1-4):573-583
In order to assess the chemical properties of groundwater and soil in ophiolitic zone of Firuzabad, in east of Shahrood, Iran, 10 soil samples with regard to sensitive points (vicinity to mine, ophiolitic rocks, and villages) and 10 groundwater samples including nine samples from springs, and also one sample from a well in a village of the study area were taken. These samples were analyzed in laboratories using inductively coupled plasma method. The soil samples were also evaluated for grain size. The obtained results show that most of heavy and major elements were exceeding the permissible levels in soil and water samples in the study area. On the subject of soil quality, concentrations of elements Cr, Mn, Fe, Ca, Mg, Ca, Ni, and Zn are above permissible levels. Enrichment factor and index of geoaccumulation have been calculated for heavy and major elements of all soil samples. According to the obtained results, it may be argued that soil samples are contaminated in relation to the above-mentioned indices. Comparing the concentrations of elements with results of grain size analysis illustrates that the concentrations of Cr, Ni, Fe, Mg, and Co are positively correlated with sand fraction and the concentrations of Al, P, Mn, and Pb are directly proportional with clay fraction in soil samples. The study on water contamination suggests that concentrations of elements Cr, Ni, and Mg in groundwater samples of the study area are above the permissible levels. Some indices like metal index and heavy metal pollution index show that most of the water samples include heavy metal contamination. 相似文献
43.
M. Hossein Sabet Otto J. Helweg 《Journal of the American Water Resources Association》1989,25(5):1047-1053
ABSTRACT: Construction of a “peaking storage tank” may reduce the operational cost of municipal water in the availability of a time-of-use energy rate. A peaking storage tank is used for storing water that is pumped from wells or other sources of supply during off-peak periods when energy costs are less for use during periods of on-peak water demand. The optimal size of a peaking storage tank is that which results in the minimum total cost, which includes both the storage construction cost and the cost of operation of the pumps. The operational cost for a given time-of-use rate is determined by help of a pipe network simulation model solved by the Newton-Raphson technique and a dynamic programming optimization model. A more simplified method is also introduced. Analyses show that low off-peak energy costs make the construction of peaking storage tanks economically attractive and reduce on-peak energy use, which results in electrical load leveling. 相似文献
44.
Vahid Mohasseli Amir Hossein Khoshgoftarmanesh Hossein Shariatmadari 《Environmental science and pollution research international》2017,24(22):17985-17992
Sulfur dioxide (SO2) is considered as a main air pollutant in industrialized areas that can damage vegetation. In the present study, we investigated how exposure to SO2 and foliar application of iron (Fe) would affect certain physiological characteristics of Plantago major. The plant seedlings exposed or unexposed to SO2 (3900 μg m?3) were non-supplemented or supplemented with Fe (3 g L?1) as foliar spray. Plants were exposed to SO2 for 6 weeks in 100 × 70 × 70 cm chambers. Fumigation of plants with SO2 was performed for 3 h daily for 3 days per week (alternate day). Lower leaf Fe concentration in the plants exposed to SO2 at no added Fe treatment was accompanied with incidence of chlorosis symptoms and reduced chlorophyll concentration. No visible chlorotic symptoms were observed on the SO2-exposed plants supplied with Fe that accumulated higher Fe in their leaves. Both at with and without added Fe treatments, catalase (CAT) and peroxidase (POD) activity was higher in the plants fumigated with SO2 in comparison with those non-fumigated with SO2. Foliar application of Fe was also effective in increasing activity of antioxidant enzymes CAT and POD. Exposure to SO2 led to reduced cellulose but enhanced lignin content of plant leaf cell wall. The results obtained showed that foliar application of Fe was effective in reducing the effects of exposure to SO2 on cell wall composition. In contrast to SO2, application of Fe increased cellulose while decreased lignin content of the leaf cell wall. This might be due to reduced oxidative stress induced by SO2 in plants supplied with Fe compared with those unsupplied with Fe. 相似文献
45.
Zhaleh Hedayat Bert Belmans M. Hossein Ayatollahi Ine Wouters Filip Descamps 《International Journal of Green Energy》2017,14(7):650-655
When designing energy efficient buildings it is useful to study existing climate—responsive building typologies. The wind towers or wind-catchers of Yazd city in Iran are typical examples of such a typology. Although many previous studies have investigated the performance of various types of wind catcher systems, studies based on a long-term real-life measurement can be rarely found. In this study a long-term whole year monitoring campaign on an existing full scale four sided wind catcher in Yazd was carried out in 2014–2015. Three prevailing wind directions were identified and the measured on-site wind speeds were used to estimate the wind induced natural ventilation potential of the tower. A shaft/tower airflow performance index was developed. The monitoring results were compared to the ASHRAE Standard 62:2001 ventilation rate requirement. Results show that the total ventilation rate of the wind tower surpasses the ASHRAE Standard requirements. Furthermore it shows that the shafts are exposed to the prevailing wind directions perform better. For more effective natural ventilation a wind tower with adaptable openings/shafts are proposed. 相似文献
46.
Marie Mequannt Yirga Fikadu Haile Mebrahtu Ehteshammajd Shaghayegh Azadi Hossein Scheffran Jürgen 《Environment, Development and Sustainability》2021,23(9):12904-12924
Environment, Development and Sustainability - Smallholder farmers are the most vulnerable community to climate change in Ethiopia since they rely heavily on the subsistence rain-fed farming system.... 相似文献
47.
Jahangir Mohammad Hossein Mousavi Seyed Ali Asayesh Zarchi Ruhollah 《Environment, Development and Sustainability》2021,23(10):14494-14527
Environment, Development and Sustainability - The tourism sectors consume a high amount of electrical power, which in most cases is supplied by the electrical grid and diesel generator. As a... 相似文献
48.
Safaynikoo Peymaneh Dehghani Mohammad Hossein 《Environmental Economics and Policy Studies》2021,23(2):441-466
Environmental Economics and Policy Studies - Economists have long argued over the political economy of tradable emission permits, especially the political pressure of lobby groups on international... 相似文献
49.
Karimi Pouria Azarpira Hossein Rasolevandi Tayebeh Sarkhosh Maryam Azizi Shohreh Mohseni Seyed Mohsen Sadani Mohsen 《Environmental science and pollution research international》2023,30(6):14630-14640
Environmental Science and Pollution Research - In this study, simultaneous removal of an organic matter (diazinon, DIZ) and an inorganic substance (chromium, Cr) was used. Breaking down of organic... 相似文献
50.
A stochastic conflict resolution model for trading pollutant discharge permits in river systems 总被引:1,自引:0,他引:1
This paper presents an efficient methodology for developing pollutant discharge permit trading in river systems considering the conflict of interests of involving decision-makers and the stakeholders. In this methodology, a trade-off curve between objectives is developed using a powerful and recently developed multi-objective genetic algorithm technique known as the Nondominated Sorting Genetic Algorithm-II (NSGA-II). The best non-dominated solution on the trade-off curve is defined using the Young conflict resolution theory, which considers the utility functions of decision makers and stakeholders of the system. These utility functions are related to the total treatment cost and a fuzzy risk of violating the water quality standards. The fuzzy risk is evaluated using the Monte Carlo analysis. Finally, an optimization model provides the trading discharge permit policies. The practical utility of the proposed methodology in decision-making is illustrated through a realistic example of the Zarjub River in the northern part of Iran. 相似文献