ABSTRACT Refrigerant pressure drop and temperature change in pipes are normally ignored in the thermodynamic analysis of traditional vehicle air conditioning system, this will result in serious errors. In this Paper, pressure drop and temperature difference are simulated in different pipes of electric vehicle (EV) heat pump system to analysis the effects of pipes in the actual EV heat pump system. The results indicate that the greater the mass flow, the faster pressure drop increases, the temperature difference decreases. Pressure drop of saturated liquid refrigerant is smaller than that of saturated gas refrigerant at the same saturation pressure and mass flow rate. The higher the refrigerant pressure (no phase change), the slower pressure drop decreases, the faster the temperature difference decreases. Pressure drop decreases with the increment of bending angle of the pipe. For EV heat pump system, suitable valves and less branches are helpful for energy saving of the system. Shortening the pipe between compressor and condenser can reduce temperature change obviously. Pressure drop per unit length in the pipe between evaporator and compressor is large especially in heating mode because of lower refrigerant density. It even reaches to over 100 times of that in the pipe between condenser and throttle valve in heating mode and has negative effects on the performance of the system. If the evaporator is closer to the compressor and the number of branches is less, then pressure drop will decrease a lot, which will be advantageous for energy saving of the heat pump system. 相似文献
• Strong metal-support interaction exists on Pt/Fe3O4 catalysts.• Pt metal particles facilitate the formation of oxygen vacancies on Fe3O4.• Fe3O4 supports enhance the strength of CO adsorption on Pt metal particles. The self-inhibition behavior due to CO poisoning on Pt metal particles strongly impairs the performance of CO oxidation. It is an effective method to use reducible metal oxides for supporting Pt metal particles to avoid self-inhibition and to improve catalytic performance. In this work, we used in situ reductions of chloroplatinic acid on commercial Fe3O4 powder to prepare heterogeneous-structured Pt/Fe3O4 catalysts in the solution of ethylene glycol. The heterogeneous Pt/Fe3O4 catalysts achieved a better catalytic performance of CO oxidation compared with the Fe3O4 powder. The temperatures of 50% and 90% CO conversion were achieved above 260°C and 290°C at Pt/Fe3O4, respectively. However, they are accomplished on Fe3O4 at temperatures higher than 310°C. XRD, XPS, and H2-TPR results confirmed that the metallic Pt atoms have a strong synergistic interaction with the Fe3O4 supports. TGA results and transient DRIFTS results proved that the Pt metal particles facilitate the release of lattice oxygen and the formation of oxygen vacancies on Fe3O4. The combined results of O2-TPD and DRIFTS indicated that the activation step of oxygen molecules at surface oxygen vacancies could potentially be the rate-determining step of the catalytic CO oxidation at Pt/Fe3O4 catalysts. The reaction pathway involves a Pt-assisted Mars-van Krevelen (MvK) mechanism. 相似文献
• Highly efficient debromination of BDE-47 was achieved in the ZVZ/AA system.• BDE-47 debromination by the ZVZ/AA can be applied to a wide range of pH.• AA inhibits the formation of (hydr)oxide and accelerates the corrosion of ZVZ.• Reduction mechanism of BDE-47 debromination by the ZVZ/AA system was proposed. A new technique of zero-valent zinc coupled with ascorbic acid (ZVZ/AA) was developed and applied to debrominate the 2,2′,4,4′-Tetrabromodiphenyl ether (BDE-47), which achieved high conversion and rapid debromination of BDE-47 to less- or non-toxic forms. The reaction conditions were optimized by the addition of 100 mg/L ZVZ particles and 3 mmol/L AA at original solution pH= 4.00 using the solvent of methanol/H2O (v:v= 4:6), which could convert approximately 94% of 5 mg/L BDE-47 into lower-brominated diphenyl ethers within a 90 min at the ZVZ/AA system. The high debromination of BDE-47 was mainly attributed to the effect of AA that inhibits the formation of Zn(II)(hydr)oxide passivation layers and promotes the corrosion of ZVZ, which leads to increase the reactivity of ZVZ. Additionally, ion chromatography and gas chromatography mass spectrometry analyses revealed that bromine ion and lower-debromination diphenyl ethers formed during the reduction of BDE-47. Furthermore, based on the generation of the intermediates products, and its concentration changes over time, it was proposed that the dominant pathway for conversion of BDE-47 was sequential debromination and the final products were diphenyl ethers. These results suggested that the ZVZ/AA system has the potential for highly efficient debromination of BDE-47 from wastewater. 相似文献
Rock ptarmigan (Lagopus muta) and willow ptarmigan (L. lagopus) are Arctic birds with a circumpolar distribution but there is limited knowledge about their status and trends across their circumpolar distribution. Here, we compiled information from 90 ptarmigan study sites from 7 Arctic countries, where almost half of the sites are still monitored. Rock ptarmigan showed an overall negative trend on Iceland and Greenland, while Svalbard and Newfoundland had positive trends, and no significant trends in Alaska. For willow ptarmigan, there was a negative trend in mid-Sweden and eastern Russia, while northern Fennoscandia, North America and Newfoundland had no significant trends. Both species displayed some periods with population cycles (short 3–6 years and long 9–12 years), but cyclicity changed through time for both species. We propose that simple, cost-efficient systematic surveys that capture the main feature of ptarmigan population dynamics can form the basis for citizen science efforts in order to fill knowledge gaps for the many regions that lack systematic ptarmigan monitoring programs.
Compound pollution refers to two or more kinds of pollutants with different properties, a pollutant from different sources, or the simultaneous existence of two or more different types of pollutants in the same environment. In this study, we aimed to investigate the individual and combined toxicity of the insecticide imidacloprid (IMI), the herbicide acetochlor (ACT), and the fungicide tebuconazole (TBZ) to zebrafish. The acute toxicity test results showed that the 96-h LC50 values of IMI, ACT, and TBZ were 276.84 (259.62–294.35) mg active ingredient (a.i.) L−1, 1.52 (1.34–1.74) mg a.i. L−1, and 8.16 (7.7–8.6) mg a.i. L−1, respectively. The combinations of IMI, ACT, and TBZ with toxicity ratios of 1:2:2, 1:4:4, 2:4:1, and 4:1:4 displayed synergistic toxic effects on zebrafish, while the toxicity ratios of 1:1:1, 1:1:2, 2:1:2, 2:2:1, and 4:2:1 of IMI, ACT, and TBZ, respectively, exhibited antagonistic toxic effects on zebrafish. The following experiments were performed with a toxicity ratio of 1:4:4 (IMI:ACT:TBZ). The activities of four enzyme biomarkers related to oxidative stress in the liver, catalase (CAT), superoxide dismutase (SOD), glutathione S-transferase (GST), and malondialdehyde (MDA) content were evaluated in each exposure group on days 7, 14, 21, and 28. Compared with those of the control group, the activities of CAT, SOD, and GST and the MDA content were significantly altered at different time points in the individual and combined exposure groups. Additionally, the activities of CAT, SOD, and GST and the MDA content were significantly altered in the combined group compared with those of the individual group after 14 days or 21 days of exposure. Therefore, it was confirmed that combined toxicity studies are indispensable in risk assessment. 相似文献
Environmental Science and Pollution Research - A series of g-C3N4/SrTiO3 (CN/SrTiO3) composites with the different mass ratio of g-C3N4 were prepared by facile in situ hydrothermal growth method,... 相似文献
Environmental Science and Pollution Research - Chinese industrial structure is characterized by a large proportion of industries with high energy consumption and high pollution, such as coal,... 相似文献
Most disaster studies rely on convenience sampling and ‘after-only’ designs to assess impacts. This paper, focusing on Hurricane Harvey (2017) and leveraging a pre-/post-event sample of Greater Houston households (n=71) in the United States, establishes baselines for disaster preparedness and home structure flood hazard mitigation, explores household-level ramifications, and examines how preparedness and mitigation relate to health effects, event exposures, and recovery. Between 70 and 80 per cent of participants instituted preparedness measures. Mitigation actions varied: six per cent had interior drainage systems and 83 per cent had elevated indoor heating/cooling components. Sixty per cent reported home damage. One-half highlighted allergies and two-thirds indicated some level of post-traumatic stress (PTS). Three-quarters worried about family members/friends. The results of generalised linear models revealed that greater pre- event mitigation was associated with fewer physical health problems and adverse experiences, lower PTS, and faster recovery. The study design exposed the broad benefits of home structure flood hazard mitigation for households after Harvey. 相似文献
Seventy-two squares of 100 ha were selected by stratified random sampling with probabilities proportional to size (pps) to survey landscape changes in the period 1996–2003. The area of the plots times the urbanization pressure was used as a size measure. The central question of this study is whether the sampling with probabilities proportional to size leads to gain in precision compared to equal probability sampling. On average 1.03 isolated buildings per 100 ha have been built, while 0.90 buildings per 100 ha have been removed, leading to a net change of 0.13 building per 100 ha. The area with unspoiled natural relief has been reduced by 2.3 ha per 100 ha, and the length of linear relicts by 137 m per 100 ha. On average 74 m of linear green elements have been planted per 100 ha, while 106 m have been removed, leading to a net change of −31 m per 100 ha. For the state variables ‘unspoiled natural relief', ‘ linear relicts', ‘removed linear green elements', and ‘new – removed linear green elements' there is a gain in precision due to the pps-sampling. For the remaining state variables there is no gain or even a loss of precision (`new buildings', ‘removed buildings', ‘new – removed buildings', ‘new linear green elements'). Therefore, if many state variables must be monitored or when interest is not only in the change but also in the current totals, we recommend to keep things simple, and to select plots with equal probability. 相似文献