首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
废物处理   1篇
环保管理   6篇
基础理论   2篇
污染及防治   5篇
评价与监测   8篇
  2022年   1篇
  2017年   1篇
  2016年   2篇
  2015年   2篇
  2013年   2篇
  2011年   1篇
  2009年   2篇
  2007年   3篇
  2006年   3篇
  2003年   2篇
  2002年   1篇
  1997年   1篇
  1996年   1篇
排序方式: 共有22条查询结果,搜索用时 15 毫秒
11.
Sludge resulting from industrial waste water treatment at the industrial area of Patras, Greece, was spiked with cadmium, chromium and lead and entrenched in 4 experimental trenches. Soil from the unsaturated zone and sludge from the trenches were sampled at successive time points over a period of 14 months to monitor the movement of metals. Results showed that 94% of cadmium and 80% of lead but only 32% of chromium migrated from the sludge just 14 months after the entrenchment.

At the end of this time the buried sludge could be considered stabilised, as indicated by the total nitrogen content. Cd content in underlying soil layers at 3 m depth showed an increase in the first 7 months followed by a decrease, afterwards. Soil Pb concentration at 3 and 6 m depth was significantly high, in relation to it's initial concentration 14 months after the entrenchment. Pb and Cd in the soil samples were negatively correlated. It is suggested that lead displaces cadmium in the sediments.  相似文献   
12.
Chemical leasing is a new and innovative approach of selling chemicals. It aims at reducing the risks emanating from hazardous substances and ensuring long-term economic success within a global system of producing and using chemicals. This paper explores how, through chemical leasing, the consumption of chemicals, energy, resources and the generation of related wastes can be reduced. It also analyses the substitution of hazardous chemicals as a tool to protect environmental, health and safety and hence ensure compliance with sustainability criteria. For this, we are proposing an evaluation methodology that seeks to provide an answer to the following research questions: (1) Does the application of chemical leasing promote sustainability in comparison to an existing chemicals production and management system? 2. If various chemical leasing project types are envisaged, which is the most promising in terms of sustainability? The proposed methodology includes a number of basic goals and sub-goals to assess the sustainability for eight different chemical leasing case studies that have been implemented both at the local and the national levels. The assessment is limited to the relative assessment of specific case studies and allows the comparisons of different projects in terms of their relative contribution to sustainable chemistry. The findings of our assessment demonstrate that chemical leasing can be regarded as promoting sustainable chemistry in five case studies with certainty. However, on the grounds of our assessment, we cannot conclude with certainty that chemical leasing has equivalent contribution to sustainable chemistry in respect of three further case studies.  相似文献   
13.
Vassova lagoon is a typical Mediterranean (small, shallow, micro-tidal, well-mixed) coastal lagoon, receiving limited seasonal freshwater inflows from direct precipitation and underground seepage. An intensive study was carried out in order to quantify the mechanisms responsible for the intra-tidal and residual transport of water, salt, nutrients and chlorophyll at the mouth of this lagoon and to assess the lagoon's flushing behavior. Results indicated that although the system is micro-tidal, tidal effects appeared to be the dominant factor for the longitudinal distribution of physical and chemical parameters, while the associated residual flow is also important and serves as a baseline measure of overall circulation. However, analysis of the net longitudinal currents and fluxes of water, salt and nutrients revealed the importance of non-tidal effects (wind effect and precipitation incidents) in the mean tidal transport. It is shown that the Eulerian residual currents transported water and its properties inwards under southern winds, while a seaward transport was induced during precipitation incidents and northern winds. The Stokes drift effect was found an order of magnitude lower than the Eulerian current, directed towards the lagoon, proving the partially-progressive nature of the tide. Nutrients and chlorophyll-α loads are exported from the lagoon to the open sea during the ebb phase of the autumn and winter tidal cycles, associated with the inflow of nutrient-rich freshwater, seeped through the surrounding drainage canal. The reverse transport occurs in spring and early summer, when nutrients enter the lagoon during the flood tidal phase, from the nutrient-rich upper layer of the stratified adjacent sea. Application of a tidal prism model shows that Vassova lagoon has a mean flushing time of 7.5 days, ranging between 4 to 18 days, affected inversely by the tidal oscillation.  相似文献   
14.
In an attempt to evaluate the background levels of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), non-ortho, mono-ortho and indicator polychlorinated biphenyls (PCBs) in people living in an urban (Athens) and a rural (Kozani) area of Greece, blood serum and mother milk samples were analyzed. Analytical results are reported in this study. Statistically significantly differences were observed between regions, sexes and ages. Contamination levels in blood and human milk from Greece reported here are low compared to the previously reported dioxin data from other European countries and give no indication of particular health risk.  相似文献   
15.
A water quality monitoring program was undertaken from June 2004 to May 2005, on a monthly basis, in Polyphytos Reservoir of Aliakmon River. Depth, water temperature, dissolved oxygen, conductivity, pH and transparency (Secchi disk) were measured in situ, while collected water samples were analyzed in the laboratory for the determination of BOD, COD, total phosphorus (TP), ortho-phosphate (OP), chlorophyll-a (Chl-a), ammonium, nitrite and nitrate, total Kappajeldahl nitrogen (TKN) and heavy metals (Fe, Mn, Cu, Cr, Pb, Ni and Cd). Measured concentrations were compared to those from two previous studies conducted in July 1987 to June 1988 and January 1991 to February 1993. The following conclusions are drawn: the effect of the watershed on the lake environment, mostly through Aliakmon River, is significant, and it accelerates the eutrophication of the lake. The anoxic zones, which were defined in the lake, reinforce this conclusion. Nitrate, nitrite and ammonia were measured at lower concentrations compared to previous studies, while total phosphorus and chlorophyll-a were found at increased concentrations. The current trophic state of Polyphytos reservoir is eutrophic, based on the OECD method and Carlson's Trophic State Indices (TSI). The concentration of BOD and COD ranged at low levels. Furthermore, the mean concentrations of metals Fe, Mn, Cu, Cr, Pb, and Cd were below the potable water standards set by WHO and EU. During most part of the study period the ratio N/P for Polyphytos reservoir was higher than 7.2:1, and therefore, phosphorus is the limiting nutrient for algal growth.  相似文献   
16.
Geographic information systems (GIS) use is presented in the problem of sitting areas for construction of natural systems such as stabilization ponds (SPs) for domestic wastewater treatment. For this purpose, several variables, such as topography, land use, type of geological formation, distance to major rivers or lakes, distance to existing cities and villages, existence of environmentally protected areas, mean minimum monthly temperatures and required wastewater effluent characteristics were analyzed with the GIS, in order to accept or reject a particular area within a region. The method is applied in the region of Thrace (Northeast Greece) at the municipal level. The required area for SP systems was calculated in each of the 36 municipalities of Thrace (including two islands, Thassos and Samothraki) as a function of the population of each municipality, temperature and local wastewater effluent discharge criteria. Based on the GIS analysis, suitable locations were identified in each municipality first, and then the total required surface area of these systems was compared to the available surface area of each municipality, in order to decide whether SP systems could be a viable solution to the wastewater management problem in the particular region. In that way the present methodology offers a fast and simple method to check the suitability of new areas for construction of such systems.  相似文献   
17.
The geometry of the warm layers of stratified streams is studied on the basis of the one‐dimensional model. Particularly, the derived equations of the dimensionless length and shape of the warm layers are expressed as function of easily measured flow and density parameters, as well as, function of the interfacial friction coefficient, fi . These analytical models are also expressed in graphic forms, suitable for practical applications. Moreover, when fi cannot be estimated, approximated forms of the analytical models are also presented graphically.  相似文献   
18.
19.
Performance of a full-scale duckweed-covered treatment system in removing faecal bacteria is presented. The system consisted of three ponds in series and received septage from holding tanks. Inflow averaged between 36 m3 d−1 in the cold season and 60 m3 d−1 in the warm season, resulting in a total hydraulic retention time of 88 and 58 days, respectively. Duckweed (Lemna minor) colonized the ponds in the summer and continued to grow in the cold season. Due to the difficult harvesting process of the duckweed biomass, the investigation of the treatment efficiency was carried out without plant harvesting. The system was monitored for temperature, pH, oxygen, chlorophyll-a, Escherichia coli and Enterococci. Duckweed growth resulted in chlorophyll-a concentration reduction from 924 to 13 μg L−1, causing neutral and anoxic conditions in the pond water. A temperature effect was noticed on the E. coli decay coefficient with a decreasing trend along the treatment system. Enterococci always decayed less than E. coli. Differences on decay coefficients and removal efficiencies were not observed between the three ponds for both bacterial types. Effluent quality in terms of E. coli was 489 and 1377 cfu/100 mL, in the warm and the cold seasons, respectively, with average removals of 99.65 ± 1.46% and 99.33 ± 3.03%. Total Enterococci removal was 88.91 ± 23.1% in the warm season and 94.43 ± 24.45% in the cold season, resulting in mean effluent values of 1058 and 1404 cfu/100 mL, respectively. The seasonal differences in total removal efficiencies were insignificant for both bacterial types.  相似文献   
20.
Characterization of Rain and Roof Drainage Water Quality in Xanthi, Greece   总被引:1,自引:0,他引:1  
Thirteen field campaigns were undertaken in the period from December 2, 2002 until September 1, 2004 to collect water samples in order to characterize the quality of rainfall and roof drainage in the city of Xanthi, a typical provincial city in Greece. In each campaign, water samples were collected from 10 representative sites in the city (in total 130 samples), representing areas of distinct land use and human activities (i.e., traffic volume, residence density and industrial activity). The water samples were analyzed according to drinking water criteria for total coliform (not detected), temperature (range: 0.9–20°C), pH (range: 3.6–11.4), alkalinity (range: 0–21.5 mg CaCO3/L), nitrate (range: 0–2456 μg/L), ammonium (range: 0–2628 μg/L), sulfate (range: 0–0.5 mg/L), calcium (range: 259.1–3064 μeq/L), magnesium (range: 0.8–488.8 μeq/L), potassium (range: 0.0–110.6 μeq/L) and dissolved heavy metals (Fe, range: 0.01–0.18 mg/L; Mn, range: 0.01–0.09 mg/L; Zn, range: 0.01–0.54 mg/L; Cu, Cr and Ni, not detected). Pollutant concentrations were generally higher in roof drainage than in rainwater, but both were lower than drinking water standards. Dissolved heavy metal concentrations were generally higher in the areas of intensive human activities, such as roads with high traffic volume and densely populated residential areas. The satisfactory quality of rainwater, which results from this analysis, makes its use as grey water possible.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号