首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   173篇
  免费   2篇
安全科学   4篇
废物处理   5篇
环保管理   9篇
综合类   47篇
基础理论   33篇
环境理论   1篇
污染及防治   61篇
评价与监测   4篇
社会与环境   11篇
  2023年   4篇
  2022年   9篇
  2021年   5篇
  2020年   3篇
  2019年   9篇
  2018年   5篇
  2017年   9篇
  2016年   13篇
  2015年   6篇
  2014年   6篇
  2013年   10篇
  2012年   8篇
  2011年   14篇
  2010年   4篇
  2009年   11篇
  2008年   12篇
  2007年   9篇
  2006年   6篇
  2005年   6篇
  2004年   4篇
  2003年   9篇
  2002年   10篇
  2001年   1篇
  1993年   1篇
  1992年   1篇
排序方式: 共有175条查询结果,搜索用时 31 毫秒
41.
The photolysis of was studied for the removal of acetic acid in aqueous solution and compared with the H2O2/UV system. The radicals generated from the UV irradiation of ions yield a greater mineralization of acetic acid than the OH radicals. Acetic acid is oxidized by radicals without significant formation of intermediate by-products. Increasing system pH results in the formation of OH radicals from radicals. Maximum acetic acid degradation occurred at pH 5. The results suggest that above this pH, competitive reactions with the carbon mineralized inhibit the reaction of the solute with and also OH radicals. Scavenging effects of two naturally occurring ions were tested; in contrast to ions, the presence of Cl ions enhances the efficiency of the /UV process towards the acetate removal. It is attributed to the formation of the Cl radical and its great reactivity towards acetate.  相似文献   
42.
Spatial concentration distribution of a chemical in an indoor environment is an important factor in the evaluation of chemical nuisances. However, straightforward techniques for the determination of this distribution are not very common and usually limited in their application. Sorptive sampling using polydimethylsiloxane-coated stir bars and the combination of active and diffusive sampling were shown to allow uncomplicated spatial concentration profiling of multiple compounds in an indoor environment. The validity of the approach was demonstrated in the analysis of the spatial concentration distribution of a pyrethroid insecticide in a common bedroom. The relative concentrations of allethrin and piperonyl butoxide were profiled throughout the room upon the application of an insecticide vaporizer.  相似文献   
43.
Chèvre N  Brazzale AR 《Chemosphere》2008,72(5):803-810
Modeling concentration-response function became extremely popular in ecotoxicology during the last decade. Indeed, modeling allows determining the total response pattern of a given substance. However, reliable modeling is consuming in term of data, which is in contradiction with the current trend in ecotoxicology, which aims to reduce, for cost and ethical reasons, the number of data produced during an experiment. It is therefore crucial to determine experimental design in a cost-effective manner. In this paper, we propose to use the theory of locally D-optimal designs to determine the set of concentrations to be tested so that the parameters of the concentration-response function can be estimated with high precision. We illustrated this approach by determining the locally D-optimal designs to estimate the toxicity of the herbicide dinoseb on daphnids and algae. The results show that the number of concentrations to be tested is often equal to the number of parameters and often related to the their meaning, i.e. they are located close to the parameters. Furthermore, the results show that the locally D-optimal design often has the minimal number of support points and is not much sensitive to small changes in nominal values of the parameters. In order to reduce the experimental cost and the use of test organisms, especially in case of long-term studies, reliable nominal values may therefore be fixed based on prior knowledge and literature research instead of on preliminary experiments.  相似文献   
44.
We evaluated the impact of the 1999 Belgian dioxin incident on the blood plasma polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) levels among 232 Belgian blood donors (74% men, mean age 47 years). The Red Cross made plasma samples from before the incident of these donors available. A second plasma sample was collected during the second half of 2000. The sum of the 17 PCDD/F congeners was significantly lower in 2000 compared to 1998 (417 pg/g fat versus 445 pg/g fat, respectively). This could be completely attributed to the significant decrease of OctaCDD (301 pg/g fat in 2000 versus 277 pg/g fat in 1998). Moreover a slight but significant decrease was observed for 2,3,7,8-TetraCDF and for 1,2,3,4,6,7,8-HeptaCDF. 1,2,3,7,8-PentaCDF and 2,3,4,7,8-PentaCDF however showed a slight but significant increase (respective levels in 1998 were 0.004 and 14.5 pg/g fat compared to 0.006 and 17.9 pg/g fat in 2000). Given their significantly higher presence in incident related food samples this increase can be attributed to the food contamination episode. However, the total toxicity remained unchanged (22.9 in 1998 versus 23.1 pg WHO-TEQ/g fat, p>0.05). Moreover the observed congener profiles and the total PCDD/F levels were similar to those of other European non-occupationally exposed populations. In conclusion, the 1999 PCB/dioxin incident was traceable in the plasma profiles (rise of the two specific PCDF congeners), but comparison of the results for both years indicates that the changes were too small to cause an adverse public health effect.  相似文献   
45.
46.
Biological barriers are a beneficial application of biofilms that aim at reducing the hydraulic conductivity (K) in geological formations. Several studies have shown the potential benefits of creating such barriers either by stimulating the indigenous microbial community (biostimulation) or injecting bacteria (bioaugmentation). For example, laboratory experiments show that groundwater microorganisms attached to a ceramic surface and generated a biofilm as thick as 1,100 μm. In a limestone fracture, this bacterial community clogged a single fracture up to 99.2 percent within 22 days. At the field scale, applications in porous aquifers led to a five‐fold decrease in K after 2.5 days of biostimulation, and a bioaugmentation with a starved, adapted bacterial culture decreased K by 99.4 percent. One promising development of the biobarrier concept is a field application at a fractured bedrock site. Using a multidisciplinary approach and focusing on a well‐characterized fracture system, a field trial was undertaken in Southern Ontario to measure the extent of bioclogging and the stability over time. This article focuses on the literature pertinent to the preparation of this field trial and presents the innovative approach selected to monitor the bioclogging in such a challenging environment.  相似文献   
47.
Biosolids are applied to vineyards to supply organic matter. However, there is concern that this practice can increase the concentration of macronutrients and heavy metals in the soil, some of which can leach. We evaluated the environmental hazard of sewage sludge compost applied in March 1999 at 10, 30, and 90 Mg ha-1 fresh weight in a vineyard in southeastern France. Soil organic matter increased in all plots by 3 g kg-1 18 mo after the amendment. Neither total nor available heavy metal concentrations increased in the soil. Mineral nitrogen (N) in the topsoil of amended plots of 10, 30, and 90 Mg ha-1 increased by 5, 14, and 26 kg (NO3(-)-N + NH4(+)-N) ha-1, respectively, the first summer and by 2, 5, and 10 kg (NO3(-)-N + NH4(+)-N) ha-1, respectively, the second summer compared with controls. At the recommended rate, risks of N leaching is very low, but phosphorus (P) appeared to be the limiting factor. Phosphorus significantly increased only in plots amended with the highest rate in the topsoil and subsoil. At lower rates, although no significant differences were observed, P added was greater than the quantities absorbed by vines. In the long run, P will accumulate in the soil and may reach concentrations that will pose a risk to surface waters and ground water. Therefore, although the current recommended rate (10 Mg ha-1) increased soil organic matter without the risk of N leaching, total sewage sludge loading rates on vineyards should be based on P concentrations.  相似文献   
48.
49.
We examined how fire hazard was affected by prescribed burning and fuel recovery over the first six years following treatment. Eight common Mediterranean fuel complexes managed by means of prescribed burning in limestone Provence (South-Eastern France) were studied, illustrating forest and woodland, garrigue and grassland situations. The coupled atmosphere-wildfire behaviour model FIRETEC was used to simulate fire behaviour (ROS, intensity) in these complex vegetations. The temporal threshold related to the effectiveness of prescribed burning in reducing the fire hazard was assessed from derivated fuel dynamics after treatment. The study showed that prescribed burning treatment was effective for the first two years in most of the Mediterranean plant communities analysed. Thereafter, all forests and shrublands were highly combustible with a fire line intensity of more than 5000 kW/m except for pine stands with or without oak (medium intensity of 2000 kW m−1 3 years after treatment). Low fire line intensity (900 kW m−1) was obtained for grassland which was entirely treatment-independent since the resprouter hemicryptophyte, Brachypodium retusum, is highly resilient to fire. Fire behaviour was greatly affected by fuel load accumulation of Quercus ilex in woodland, and by standing necromass of Rosmarinus officinalis in treated garrigue. Pure pine stands with shrub strata similar to garrigue showed a lower fire intensity due to wind speed decrease at ground level under tree canopy, underlining the advantage of maintaining a proportion of canopy cover in strategic fuel-break zones.  相似文献   
50.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号