首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   1篇
  国内免费   8篇
安全科学   10篇
废物处理   10篇
环保管理   11篇
综合类   19篇
基础理论   25篇
污染及防治   39篇
评价与监测   11篇
社会与环境   2篇
  2022年   3篇
  2021年   5篇
  2019年   4篇
  2018年   10篇
  2017年   7篇
  2016年   6篇
  2014年   4篇
  2013年   19篇
  2012年   6篇
  2011年   10篇
  2010年   6篇
  2009年   11篇
  2008年   11篇
  2007年   6篇
  2006年   3篇
  2005年   4篇
  2004年   4篇
  2003年   1篇
  2002年   2篇
  2001年   4篇
  2000年   1篇
排序方式: 共有127条查询结果,搜索用时 15 毫秒
81.
The capabilities of selected strains from genera Lactobacillus and Bifidobacterium to produce extracellular bioactive compounds with antimutagenic properties against benzo[a]pyrene (BaP) and sodium azide (SA) were tested as a function of growth phase. The bacterial supernatants from exponential and stationary phases were characterized with different patterns of antimutagenic activity against the two mutagens. All lactobacilli exhibited either no effect or low antimutagenicity against BaP during exponential growth. Higher antimutagenic activities of lactobacilli supernatants were observed in the stationary phase against SA as well. An exception was Lactobacillus sakei 23K which expressed a relatively low percent of inhibition of mutagenesis (PI = 28.14 +/- 7.41) in the exponential phase and no antimutagenic activity in the stationary phase. Of the bifidobacteria, only Bifidobacterium adoleascentis ATCC 15703 exhibited higher antimutagenecity against BaP in the exponential phase. The same bacterial supernatants however, did not possess any antimutagenicity against SA in either the exponential or stationary phases. B. bifidum ATCC 11863 did not express any significant differences in its activity against either BaP or SA in the exponential or stationary phases. Only B. breve ATCC 15700 expressed a high antimutagenic effect against SA in the stationary phase but exhibited no effect during exponential growth. Overall, bacterial antimutagenic responses were associated with growth phase and type of mutagen.  相似文献   
82.
Abstract: Water resources planning and management efficacy is subject to capturing inherent uncertainties stemming from climatic and hydrological inputs and models. Streamflow forecasts, critical in reservoir operation and water allocation decision making, fundamentally contain uncertainties arising from assumed initial conditions, model structure, and modeled processes. Accounting for these propagating uncertainties remains a formidable challenge. Recent enhancements in climate forecasting skill and hydrological modeling serve as an impetus for further pursuing models and model combinations capable of delivering improved streamflow forecasts. However, little consideration has been given to methodologies that include coupling both multiple climate and multiple hydrological models, increasing the pool of streamflow forecast ensemble members and accounting for cumulative sources of uncertainty. The framework presented here proposes integration and offline coupling of global climate models (GCMs), multiple regional climate models, and numerous water balance models to improve streamflow forecasting through generation of ensemble forecasts. For demonstration purposes, the framework is imposed on the Jaguaribe basin in northeastern Brazil for a hindcast of 1974‐1996 monthly streamflow. The ECHAM 4.5 and the NCEP/MRF9 GCMs and regional models, including dynamical and statistical models, are integrated with the ABCD and Soil Moisture Accounting Procedure water balance models. Precipitation hindcasts from the GCMs are downscaled via the regional models and fed into the water balance models, producing streamflow hindcasts. Multi‐model ensemble combination techniques include pooling, linear regression weighting, and a kernel density estimator to evaluate streamflow hindcasts; the latter technique exhibits superior skill compared with any single coupled model ensemble hindcast.  相似文献   
83.
A toxicity test using spore release of the aquatic green alga, Ulva, was developed and evaluated by assessing the toxicity of different organic and inorganic chemicals and elutriates of sewage or waste sludge. The toxic ranking of four metals was: Cu (EC50 of 0.040mgL(-1))>Cd (0.095mgL(-1))>Pb (0.489mgL(-1))>Zn (0.572mgL(-1)). The EC50 for TBTO ranged from 24 to 63microgL(-1). The most toxic VOC was formalin (EC50 of 0.788microlL(-1)) and the least toxic was acetone. Spore release was significantly inhibited in all elutriates; the greatest and least toxic effects were for industrial sewage (3.29%) and filtration bed (10.08%), respectively. The bioassay is simple, inexpensive and sensitive. The cosmopolitan distribution of Ulva means that the test would have a potential application worldwide.  相似文献   
84.
以反渗透膜为主,综合集成超滤、微滤、砂滤、活性碳吸附、紫外线消毒等技术措施.设计安装了适合农村自来水、井水、河水不同饮用水源深度净化处理的3套设备。运行结果表明,设备对于饮用水源中的有机物、微生物、色味臭,以及自来水中的余氯,处理效果非常明显。研究成果为解决分散型农村安全饮用水问题.提供了比较好的技术方案。  相似文献   
85.
This study evaluates the adsorption ability ofbisphenol A(BPA) on titanium dioxide(TiO2) and its effect on the photocatalysis by advanced oxidation process using UV radiation and TiO2 photocatalyst. Degradation of BPA was also evaluated for the system without adsorption prior to photocatalytic reaction. The separation of TiO2 from BPA solution treated by pilot-scale photocatalytic reactor (capacity 0.16 m^3) was studied using submerged ultrafiltration (UF) membrane. It was found that although adsorption capacity of BPA was not high, adsorption played an important role in improving the efficiency ofphotocatalysis. On the other hand, during the separation of TiO2 particles from aqueous suspension, the permeate flux of the membrane was strongly affected by transmembrane pressure and TiO2 dose. The permeate turbidity was decreased below 1 NTU.  相似文献   
86.
A comprehensive evaluation of work-related perfomance factors is a prerequisite to developing integrated and long-term solutions to workplace performance improvement. This paper describes a work-factor classification system that categorizes the entire domain of workplace factors impacting performance. A questionnaire-based instrument was developed to implement this classification system in industry. Fifty jobs were evaluated in 4 different service and manufacturing companies using the proposed questionnaire-based instrument. The reliability coefficients obtained from the analyzed jobs were considered good (.589 to .862). In general, the physical work factors resulted in higher reliability coefficients (.847 to .862) than non-physical work factors (.589 to .768). performance work-factor system classification  相似文献   
87.
In search of readily available and relatively inexpensive materials for phosphorus removal, waste oyster shell is a waste product from oyster-culturing farm and also presents a major disposal problem in itself. Activated oyster shell produced by pyrolysis at 750 °C exhibits promising performance as a suitable substance for phosphorus removal. The capacity of the activated oyster shell, in terms of equivalents of OH? per gram of material, is about 80% than that of calcium hydroxide. However, the granular nature of activated oyster shell (AOS) makes it much easier to handle than lime. This would be a very important advantage for treatment facilities that cannot afford specialized powder handling facilities necessary for lime. Another advantage of AOS is its time-release properties, which can allow it to be added to reactors intermittently and still achieve consistent phosphate precipitation. Distribution of phosphate after contact with AOS indicates that adsorption does not play a significant role in phosphate removal with AOS. Rather, it appears that the phosphate is precipitated in the presence of Ca2+ and high pH as a key mechanism. Since it is produced from a waste product of mariculture, AOS is a sustainable precipitant for phosphate removal.  相似文献   
88.
This study was designed to find the effects of two kinds of dust-free garments with (A) and without (B) frozen gel strip (FGS), and half-naked clothing (brassiere and shorts; C) on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperatures as well as sweat rate and clothing microclimate were measured during 140 min in 9 healthy females. Inquiries were also made into the subjective rating of thermal, humidity, and comfort sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal and skin temperatures (chest and forehead), heart rate, and sweat rate were clearly lowest in garb C, intermediate in garb A, and highest in garb B throughout the experiment; (b) Temperature and humidity within clothing were lower in garb A than in garb B; (c) More than half of the 9 participants decreased thermal sensation by wearing garb A. These results suggest that the usage of FGS could improve the heat load in lightly working participants wearing dust-free garments.  相似文献   
89.
Zhang Y  Zhu YX  Kwon KK  Park JH  Kim SJ 《Chemosphere》2004,55(3):389-394
To study the biodegradation rate of pyrene dissolved in liquid medium supplemented with mineral salts, a synchronous fluorimetry (SF) method was established. The limit of detection for pyrene dissolved in mineral salts medium (MSM) was determined as 0.19 ng/ml with a relative standard deviation of less than 1.3% (n = 9). The pyrene degrading rates of four bacterial strains were investigated using this method under the same experimental conditions. The degradation rates of the three active strains ranged from 76% to 87% after a 14-h incubation. The results were confirmed by the gas chromatography with a flame ionized detector (GC/FID) method. This implies that pyrene degradation can be directly monitored by the SF method without the solvent extraction of samples. The advantages of SF are that it is less laborious, faster, and less expensive than the GC/FID determination method with solvent extraction. The SF method provides a new tool for studying the degradation of polynuclear aromatic hydrocarbons (PAHs) in the natural environment and under experimental conditions.  相似文献   
90.
Screening of poultry flocks for foodborne pathogen Salmonella contamination is critical for Salmonella control in preharvest stages of poultry production. In this study, two sampling methods (litter and air filter) were compared for detection of S. typhimurium from experimentally infected chicks some of which had received either a probiotic competitive exclusion culture or transfer of cecal contents from salmonellae-free adult birds. At 4, 9, and 11 days after inoculation, S. typhimurium samples were enumerated by selective plating. For both types of sampling, the control birds yielded the greatest levels of environmental contamination followed by the samples from the probiotic inoculated birds with the birds receiving the cecal transfer culture having the lowest levels of contamination. Although the two sampling methods responded in a similar fashion, detection sensitivity needs to be increased for air filter sampling.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号