首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   119篇
  免费   1篇
  国内免费   8篇
安全科学   10篇
废物处理   10篇
环保管理   11篇
综合类   19篇
基础理论   25篇
污染及防治   39篇
评价与监测   12篇
社会与环境   2篇
  2022年   3篇
  2021年   5篇
  2019年   4篇
  2018年   10篇
  2017年   7篇
  2016年   6篇
  2014年   4篇
  2013年   19篇
  2012年   6篇
  2011年   10篇
  2010年   6篇
  2009年   11篇
  2008年   12篇
  2007年   6篇
  2006年   3篇
  2005年   4篇
  2004年   4篇
  2003年   1篇
  2002年   2篇
  2001年   4篇
  2000年   1篇
排序方式: 共有128条查询结果,搜索用时 31 毫秒
11.
The combination of bioremediation and electrokinetics, termed bioelectrokinetics, has been studied constantly to enhance the removal of organic and inorganic contaminants from soil. The use of the bioleaching process originating from Fe- and/or S-oxidizing bacteria may be a feasible technology for the remediation of heavy metal-contaminated soils. In this study, the bioleaching process driven by injection of S-oxidizing bacteria, Acidithiobacillus thiooxidans, was evaluated as a pre-treatment step. The bioleaching process was sequentially integrated with the electrokinetic soil process, and the final removal efficiency of the combined process was compared with those of individual processes. Tailing soil, heavily contaminated with Cd, Cu, Pb, Zn, Co, and As, was collected from an abandoned mine area in Korea. The results of geochemical studies supported that this tailing soil contains the reduced forms of sulfur that can be an energy source for A. thiooxidans. From the result of the combined process, we could conclude that the bioleaching process might be a good pre-treatment step to mobilize heavy metals in tailing soil. Additionally, the electrokinetic process can be an effective technology for the removal of heavy metals from tailing soil. For the sake of generalizing the proposed bioelectrokinetic process, however, the site-specific differences in soil should be taken into account in future studies.  相似文献   
12.
13.
This study investigated the effect of adding vanadium (V) to natural manganese oxide (NMO) in ammonia (NH3) selective catalytic reduction (SCR). The addition of V to NMO decreased the catalytic activity at low temperatures by blocking the active site. However, the enhancement of catalytic activity was achieved by controlling NH3 oxidation at high temperatures. From the NH3 temperature programmed desorption and oxygen on/off test, it was confirmed that the amount of Lewis acid site and active lattice oxygen of the catalyst affects the catalytic performance at low temperature.  相似文献   
14.
In South Korea, nine million tons of fly ash (FA) are annually produced and approximately 70 % is reutilized for industrial demand. For the prompt reuse and insufficient reclamation site, quality control of FA which is main productive construction material from coal ash is very important. Assessed Pozzolanic-activity Index (API) test which needs only 2 days for evaluation of pozzolanic reaction is currently considered as an alternative of activity index measurement. This paper aims for an applicability of API test for prompt quality control and investigation of domestic FA properties. For the work, FAs from two different power plant types are prepared, and quality tests are carried out based on Korean Standards (KS) methods and API method. Lots of test results are compared with those from API and K-value test for FA with age of 7 days–1 year. From the test results for FA aged 1 year, API results are evaluated to be closely related with those from activity index and K-value, and the correlations are improved with increasing ages regardless of plant types. The applicability of API test is verified and the reduced period of FA quality evaluation can accelerate prompt use and the related process of FA.  相似文献   
15.
This paper discusses about the quantitative effect of windbreak fences on wind velocity in the reclaimed land at Saemangeum in South Korea. Windbreak fences were constructed in the reclaimed land to reduce the wind velocity to prevent the generation and diffusion of dust. However, up to this time, no in-depth studies were conducted to quantitatively measure the effect of the windbreak fences on wind velocity thus an optimum windbreak structure is not yet determined. Using CFD simulations, the effects of fence porosity, fence height, and the distance between the adjacent fences were investigated. A wind tunnel experiment was initially conducted and data gathered were used to develop the CFD models. From the experiments and CFD simulations, the overall percentage difference of the measured velocities was 7.20% which is generally acceptable to establishing the reliability of the CFD models. The reduction effect on wind velocity was measured in between the adjacent fences up to a height of 0.6 m from the ground surface. In terms of porosity ( = 0, 0.2, 0.4, 0.6), 0.2 was found to be the optimum value. Conversely, the effect of fence height (0.6, 0.8 and 1.0 m) showed no significant difference; therefore, 0.6 m height is recommended. In addition, the reduction effect of distance between the adjacent fences (2, 4 and 6 m) on wind velocity having a 0.2 porosity has decreased to about 75% regardless of the distance. In the case of the reclaimed land in Saemangeum, a decrease of 75% can prevent the generation and diffusion of dusts. However, the source of dusts is very large. Therefore, constructing an array of windbreak with 6 m distance between them is deemed necessary.  相似文献   
16.
This study is aimed at exploring the characteristics of fatal occupational injuries in Korea’s construction industry and comparing the causes in various occupations within that industry. There were 10,276 fatal occupational injury victims in Korea over 8 years (1997–2004). The mortality risk due to injuries in construction and non-construction industries was calculated, and their causes were compared. The number of victims of fatal occupational injuries in the construction industry was 4333 (42.2% of the total fatal occupational injuries), and the 1 year mortality risk was higher (23.7/100,000 persons) than in non-construction industries (10.4). Falling was the most frequent (52.7%) cause of fatal injuries. In addition, deaths due to structural collapse and electric shock were significantly higher than in other industries. When the distribution of the causal factors in various occupations within the construction industry was investigated, some factors appeared more frequently in certain occupations than in others. As the construction industry encompasses a large proportion of occupational injuries, a reduction in this field alone will substantially contribute to an overall reduction of occupational injuries in Korea. Further research for effective prevention is needed.  相似文献   
17.
Our objective was to evaluate distribution and accumulation of trace elements (TEs) in surface sediments along the Hooghly (Ganges) River Estuary, India, and to assess the potential risk with view to human health. The TE concentrations (mg kg?1 dry weight) exhibited a wide range in the following order: Al (31.801 ± 15.943) > Fe (23.337 ± 7584) > Mn (461 ± 147) > S (381 ± 235) > Zn (54 ± 18) > V (43 ± 14) > Cr (39 ± 15) > As (34 ± 15) > Cu (27 ± 11) > Ni (24 ± 9) > Se (17 ± 8) > Co (11 ± 3) > Mo (10 ± 2) > Hg (0.02 ± 0.01). Clay, silt, iron, manganese and sulphur were important for the accumulation of TE in the sediments as confirmed by factor analysis and Pearson correlation. The accumulation and dispersal of TEs were most likely to be governed by both tide-induced processes and anthropogenic inputs from point and non-point sources. Enrichment factor analysis and geoaccumulation index revealed serious contamination of the sediments with Se and As, while comparing the consensus-based sediment quality guidelines (SQGs), adverse biological effects to benthic fauna might be caused by As, Cu, Ni and Cr. This investigation may serve as a model study and recommends continuous monitoring of As, Se, Cu, Ni and Cr to ascertain that SQGs with respect to acceptable levels of TEs to safeguard geochemical health and ecology in the vicinity of this estuary.  相似文献   
18.
Abstract

Screening of poultry flocks for foodborne pathogen Salmonella contamination is critical for Salmonella control in preharvest stages of poultry production. In this study, two sampling methods (litter and air filter) were compared for detection of S. typhimurium from experimentally infected chicks some of which had received either a probiotic competitive exclusion culture or transfer of cecal contents from salmonellae‐free adult birds. At 4, 9, and 11 days after inoculation, S. typhimurium samples were enumerated by selective plating. For both types of sampling, the control birds yielded the greatest levels of environmental contamination followed by the samples from the probiotic inoculated birds with the birds receiving the cecal transfer culture having the lowest levels of contamination. Although the two sampling methods responded in a similar fashion, detection sensitivity needs to be increased for air filter sampling.  相似文献   
19.
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries.  相似文献   
20.
Due to high usage of tetracycline antibiotics, concerns have been raised about their environmental fate. In this study, potential changes in the pseudo-first-order hydrolysis rate constants for three tetracyclines, tetracycline (TC), oxytetracycline (OTC) and chlortetracycline (CTC), were evaluated by measuring the rate constants in batch and column leaching experiments. The first-order hydrolysis rate constants were measured at pH 5, 7, and 9 using batch tests. The values were highest at pH 7 for all three tetracyclines (0.0030 ± 0.0004, 0.0042 ± 0.0001, and 0.0323 ± 0.0003 h(-1) for TC, OTC, and CTC, respectively), indicating relatively short environmental half-lives of tetracyclines. Interestingly, it was found that the rates of degradation of the parent tetracyclines were much faster when silica sand was present in a batch solution or when the solution was passed through a silica column. For example, the ratios of the first-order degradation rate constants obtained in the column experiments to those in batch experiments were 13.2, 2.1, and 2.0 for TC, OTC, and CTC at a volumetric flow rate of 0.08 mL h(-1), with an observed tendency for this ratio to increase with an increased flow rate. This indicates that the silica surface may serve as a catalyst for hydrolysis and that the actual environmental half-lives of tetracycline antibiotics could be shorter than those estimated from laboratory hydrolysis rate constants using the standard batch protocol. Furthermore, the toxicity of the column effluent containing hydrolysis metabolites was assessed using bioluminescence inhibition in Vibrio fischeri. It was estimated that the toxicity of the metabolites of CTC was lower than that of their parent compound, whereas the toxicity of metabolites of TC and OTC was as high as or higher than that of their parent compounds.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号