Excessive nitrogen (N) loading to N-sensitive waters such as the Neuse River estuary (North Carolina) has been shown to promote changes in microbial and algal community composition and function (harmful algal blooms), hypoxia and anoxia, and fish kills. Previous studies have estimated that wet atmospheric deposition of nitrogen (WAD-N), as deposition of dissolved inorganic nitrogen (DIN: NO3-, NH3/NH4+) and dissolved organic nitrogen, may contribute at least 15% of the total externally supplied or "new" N flux to the coastal waters of North Carolina. In a 3-yr study from June 1996 to June 1999, we calculated the weekly wet deposition of inorganic and organic N at eleven sites on a northwest-southeast transect in the watershed. The annual mean total (wet DIN + wet organics) WAD-N flux for the Neuse River watershed was calculated to be 956 mg N/m2/yr (15026 Mg N/yr). Seasonally, the spring (March-May) and summer (June-August) months contain the highest total weekly N deposition; this pattern appears to be driven by N concentration in precipitation. There is also spatial variability in WAD-N deposition; in general, the upper portion of the watershed receives the lowest annual deposition and the middle portion of the watershed receives the highest deposition. Based on a range of watershed N retention and in-stream riverine processing values, we estimate that this flux contributes approximately 24% of the total "new" N flux to the estuary. 相似文献
INTRODUCTION: Work-related asthma has become the most prevalent occupational respiratory disease in the developed world. Occupational asthma is thought to affect 5%-10% of people worldwide. The first step in the diagnosis of occupational asthma is to establish work-relatedness. Although considerable research has been conducted in the area of occupational asthma, no simple, effective, and statistically sound method has been developed that can be used as an initial step to effectively identify the workers at risk for occupational asthma. The purpose of this research was to investigate whether Shewhart control chart method can be used as an effective method to detect occupational asthma. METHOD: Forty-five workers who completed the study and provided usable peak expiratory flow (a lung function marker) recordings while at work and away from work were included in this study. Control charts were developed using Shewhart's Method. The lower control limit of at work control chart (LCL(W)) was compared to each subject's Personal Best (PB) value. RESULTS: Reviewing the results of this comparison showed LCL(W)<60% PB to have a sensitivity of 85.71%, specificity of 87.50%, and an error rate of 13.33%. When the subjects suspected for false positive and false negative diagnoses were identified, the test produced a sensitivity of 95.24%, a specificity of 95.83% and an error rate of 4.44%. CONCLUSIONS: Our results were as good as, and in some cases better than, published clinical guidelines. IMPACT ON INDUSTRY: Our research showed that the control chart method is an effective, simple, and inexpensive tool for early intervention in workers suspected for occupational asthma. 相似文献
OBJECTIVES: It has been noted by several authors that risk (defined only in terms of total expected numbers of crash involvements per total distance driven) paints a misleading picture of crash liability, particularly for the young and the old, as their high risk is associated with risky driving patterns typical of people who drive low annual kms. This article sets out to analyze these driving patterns of low-km drivers and to evaluate the risk of these patterns. As licensing programs tend to focus on young and old drivers, who tend to drive lower annual distances, income and employment data are also analyzed for low-km drivers. This is to provide a better picture for policy makers of the sort of people and the sorts of transportation requirements that their policies may affect. METHODS: Crash data and travel data were disaggregated by driver characteristics and by driving conditions (road type, day and night, weekend and weekday) and combined to form estimates of risk for typical driving patterns of driver groups. Characteristics of driving patterns and of the drivers themselves were derived for groups defined by age and by the amount of annual driving undertaken. RESULTS: Older drivers who drive less tend to have higher risk per km mainly due to their predominantly urban trips. Nevertheless, because older drivers on average manage to reduce their risk per distance driven by choosing driving patterns that are safer than the driving patterns of other age groups, the risk of older drivers as a group is not overestimated. CONCLUSION: Despite being quite different from one another, the low- and high-km driving patterns of younger drivers were found to impose identical risks. 相似文献
Large cooking oil pool fires, occurring in industrial oil cookers, present a severe hazard to food processing plants due to their size and the large amount of hot oil involved. This paper reports a series of full-scale fire experiments conducted in a large industrial oil cooker mock-up. The characteristics of large cooking oil pool fires and the effect of oil depth and hood position in the oil cooker on fire growth were studied. The use of water mist for extinguishing large oil pool fires and their extinguishing performance under different discharge pressure and with different types of water mist systems were investigated. Experimental results showed that the cooking oil underwent a substantial expansion in volume during heating. The fires developed quickly once the oil auto-ignited. The fire growth rate was affected by the oil depth in the pan and the hood position in the oil cooker. The water mist fire suppression systems effectively extinguished large cooking oil fires and prevented them from re-igniting. Their extinguishing performance was determined by the type of water mist system, discharge pressure and hood position in the oil cooker. 相似文献
This paper presents detailed data on the thermal response of two 500 gal ASME code propane tanks that were 25% engulfed in a hydrocarbon fire. These tests were done as part of an overall test programme to study thermal protection systems for propane-filled railway tank-cars.
The fire was generated using an array of 25 liquid propane-fuelled burners. This provided a luminous fire that engulfed 25% of the tank surface on one side. The intent of these tests was to model a severe partially engulfing fire situation.
The paper presents data on the tank wall and lading temperatures and tank internal pressure. In the first test the wind reduced the fire heating and resulted in a late failure of the tank at 46 min. This tank failed catastrophically with a powerful boiling liquid expanding vapour explosion (BLEVE). In the other test, the fire heating was very severe and steady and this tank failed very quickly in 8 min as a finite rupture with massive two-phase jet release. The reasons for these different outcomes are discussed. The different failures provide a range of realistic outcomes for the subject tank and fire condition. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献
A visual-visual dual computer task was designed to test the effect of the thermal environment on dual task performance. The temperatures selected for testing were 20 and 35 °C Wet Bulb Globe Temperature (WBGT). 34 volunteers were randomly assigned to 1 of the 2 temperature conditions. Individual differences in single task performance were controlled by equating the baselines of single task performance. Once individual differences in single task capacity were controlled, statistically significant differences in performance were demonstrated. Mean accuracy was computed over a 1-hr testing period in each temperature condition. Participants’ mean accuracy in the 35° condition (38.18%) was substantially lower than in the 20° condition (50.88%). 相似文献