首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   102篇
  免费   0篇
  国内免费   4篇
安全科学   9篇
废物处理   22篇
环保管理   6篇
综合类   9篇
基础理论   16篇
污染及防治   22篇
评价与监测   14篇
社会与环境   8篇
  2023年   4篇
  2022年   12篇
  2021年   8篇
  2020年   1篇
  2019年   5篇
  2018年   9篇
  2017年   6篇
  2016年   5篇
  2015年   6篇
  2014年   4篇
  2013年   12篇
  2012年   6篇
  2011年   10篇
  2010年   2篇
  2009年   6篇
  2008年   1篇
  2007年   3篇
  2006年   2篇
  2005年   2篇
  2004年   1篇
  1985年   1篇
排序方式: 共有106条查询结果,搜索用时 203 毫秒
41.
Background. Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body’s movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. Materials and methods. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. Results. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p?<?0.05). Conclusion. Overall, this study indicated that applying ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.  相似文献   
42.
A steady-state space radiant heat model and a stove combustion model are developed to simulate the heat exchanges between various surfaces in the room and the stove and stack surfaces, assuming stiochiometric combustion inside the stove and the exhaust gases flow out through the stack by natural convection. The space heat model calculates the fuel consumption, the stove, stack temperatures, and the mass flow rate of exhaust gases, and provides an opportunity to study the energy efficiency of the stove, while satisfying the constraints of thermal comfort. Fanger (1982) Fanger, P. O. 1982. Thermal Comfort Analysis and Applications in Engineering, 156198. New York: McGraw Hill.  [Google Scholar] model and a radiation exchange model between various surfaces of the space, the thermal building energy balance, and stove combustion process is applied to determine the mean radiant temperature (MRT) and the extent of thermal comfort as determined by predicted mean vote (PMV).

The overall model is validated by performing experiments in a room placed inside a controlled outdoor environment. The room is heated using a domestic stove common for rural areas of Lebanon and the MRT, the room air temperature, the walls and window temperatures are measured at two stove positions. The measured MRT, the average room temperature, and the wall surface temperatures agreed within ±7% of values predicted by the numerical model.

A parametric study is performed to optimize the stove and occupant locations in the room where adequate comfort level can be maintained at lower fuel consumption levels. The values of MRT and PMV depend strongly on the position of the radiant stove heater and stack with respect to the cold window and the occupant location. It is shown that it is possible to save up to 15% in stove fuel consumption by changing the stove position in the room with respect to the window and to the person, while maintaining the same level of comfort.  相似文献   
43.
Journal of Polymers and the Environment - The present work presents an analysis of the tensile properties of Palm as well as Luffa natural fiber composites (NFC) in high density polyethylene...  相似文献   
44.
45.
Environmental Science and Pollution Research - The utilization of plastics has now become a threat to the environment as it generates microplastic particles (&lt;5 mm in size). The increasing...  相似文献   
46.
Environmental Science and Pollution Research - In this work, waste cooking palm oil (WCPO)-based carbon nanotubes (CNTs) with encapsulated iron (Fe) nanoparticles have been successfully produced...  相似文献   
47.
From environmental viewpoint, the most important advantage of compact fluorescent lamps (CFLs) is reduction of green house gas emissions. But their significant disadvantage is disposal of spent lamps because of containing a few milligrams of toxic metals, especially mercury and lead. For a successful implementation of any waste management plan, availability of sufficient and accurate information on quantities and compositions of the generated waste and current management conditions is a fundamental prerequisite. In this study, CFLs were selected among 20 different brands in Iran. Content of heavy metals including mercury, lead, nickel, arsenic and chromium was determined by inductive coupled plasma (ICP). Two cities, Tehran and Tabriz, were selected for assessing the current waste management condition of CFLs. The study found that waste generation amount of CFLs in the country was about 159.80, 183.82 and 153.75 million per year in 2010, 2011 and 2012, respectively. Waste generation rate of CFLs in Iran was determined to be 2.05 per person in 2012. The average amount of mercury, lead, nickel, arsenic and chromium was 0.417, 2.33, 0.064, 0.056 and 0.012 mg per lamp, respectively. Currently, waste of CFLs is disposed by municipal waste stream in waste landfills. For improving the current conditions, we propose by considering the successful experience of extended producer responsibility (EPR) in other electronic waste management. The EPR program with advanced recycling fee (ARF) is implemented for collecting and then recycling CFLs. For encouraging consumers to take the spent CFLs back at the end of the products’ useful life, a proportion of ARF (for example, 50%) can be refunded. On the other hand, the government and Environmental Protection Agency should support and encourage recycling companies of CFLs both technically and financially in the first place.  相似文献   
48.
This study aimed to evaluate possible health effects associated with long-term occupational exposure to low levels of mercury vapors. Forty-six subjects exposed to mercury and 65 healthy unexposed employees were studied. The subjects were administered a questionnaire on experienced symptoms and underwent clinical examinations as well as routine biochemical tests. Atmospheric and urinary concentrations of mercury were measured, too. Environmental concentrations of mercury were estimated to be 3.97 ± 6.28 μg/m(3) and urinary concentrations of mercury in exposed and referent groups were 34.30 ± 26.77 and 10.15 ± 3.82 μg/dm(3), respectively. Additionally, symptoms such as somatic fatigue, anorexia, loss of memory, erethism, blurred vision and teeth problems were significantly more common among exposed individuals. These observations indicate that occupational exposure to mercury vapors, even at low levels, is likely to be associated with neurological and psychological symptoms.  相似文献   
49.
Journal of Material Cycles and Waste Management - This study focuses on the potential usage of sago pith waste ash (SPWA) obtained from sago pith waste (SPW) calcined from 500 to...  相似文献   
50.
This study investigated the concentration of potentially toxic elements (PTEs) including Al, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Mo, Ni, Pb, Sb, V, and Zn in 102 soils (in the Near and Far areas of the mine), 7 tailings, and 60 plant samples (shoots and roots of Artemisia sieberi and Zygophylum species) collected at the Gol-E-Gohar iron ore mine in Iran. The elemental concentrations in tailings and soil samples (in Near and Far areas) varied between 7.4 and 35.8 mg kg?1 for As (with a mean of 25.39 mg kg?1 for tailings), 7.9 and 261.5 mg kg?1 (mean 189.83 mg kg?1 for tailings) for Co, 17.7 and 885.03 mg kg?1 (mean 472.77 mg kg?1 for tailings) for Cu, 12,500 and 400,000 mg kg?1 (mean 120,642.86 mg kg?1 for tailings) for Fe, and 28.1 and 278.1 mg kg?1 (mean 150.29 mg kg?1 for tailings) for Ni. A number of physicochemical parameters and pollution index for soils were determined around the mine. Sequential extractions of tailings and soil samples indicated that Fe, Cr, and Co were the least mobile and that Mn, Zn, Cu, and As were potentially available for plants uptake. Similar to soil, the concentration of Al, As, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Zn in plant samples decreased with the distance from the mining/processing areas. Data on plants showed that metal concentrations in shoots usually exceeded those in roots and varied significantly between the two investigated species (Artemisia sieberi > Zygophylum). All the reported results suggest that the soil and plants near the iron ore mine are contaminated with PTEs and that they can be potentially dispersed in the environment via aerosol transport and deposition.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号