首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   105篇
  免费   0篇
安全科学   7篇
废物处理   7篇
环保管理   8篇
综合类   3篇
基础理论   12篇
污染及防治   41篇
评价与监测   18篇
社会与环境   9篇
  2023年   2篇
  2022年   5篇
  2021年   2篇
  2018年   5篇
  2017年   2篇
  2016年   3篇
  2014年   8篇
  2013年   10篇
  2012年   8篇
  2011年   2篇
  2010年   9篇
  2009年   5篇
  2008年   9篇
  2007年   9篇
  2006年   4篇
  2005年   3篇
  2004年   7篇
  2003年   6篇
  2002年   3篇
  2000年   1篇
  1999年   1篇
  1997年   1篇
排序方式: 共有105条查询结果,搜索用时 125 毫秒
91.
The purpose of this research was to study the fate and toxicity of triclosan (TCS) in activated sludge systems and to investigate the role of biodegradation and sorption on its removal. Two continuous-flow activated sludge systems were used; one system was used as a control, while the other received TCS concentrations equal to 0.5 and 2mgl(-1). At the end of the experiment, 1mgl(-1) TCS was added in the control system to investigate TCS behaviour and effects on non-acclimatized biomass. For all concentrations tested, more than 90% of the added TCS was removed during the activated sludge process. Determination of TCS in the dissolved and particulate phase and calculation of its mass flux revealed that TCS was mainly biodegraded. Activated sludge ability to biodegrade TCS depended on biomass acclimatization and resulted in a mean biodegradation of 97%. Experiments with batch and continuous-flow systems revealed that TCS is rapidly sorbed on the suspended solids and afterwards, direct biodegradation of sorbed TCS is performed. Regarding TCS effects on activated sludge process, addition of 0.5mgl(-1) TCS on non-acclimatized biomass initially deteriorated ammonia removal and nitrification capacity. After acclimatization of biomass, nitrification was fully recovered and further increase of TCS to 2mgl(-1) did not affect the performance of activated sludge system. The effect of TCS on organic substrate removal was minor for concentrations up to 2mgl(-1), indicating that heterotrophic microorganisms are less sensitive to TCS than nitrifiers.  相似文献   
92.
Groundwater hydrogeochemistry of Trikala municipality, central Greece   总被引:1,自引:0,他引:1  
Sixty-four samples from the groundwater resources of Trikala municipality, central Greece, were collected during two periods (2006 and 2007) and analyzed for physico-chemical parameters (temperature, pH, specific electrical conductivity, and total dissolved solids), major ions (Ca2+, Cl?, HCO 3 ? , K+, Mg2+, Na+, NO 3 ? , SO 4 2? ), and several potentially toxic elements (Al, B, Ba, Br, Ca, Ce, Cl, Cr, Cu, Fe, K, La, Li, Mg, Mn, Mo, Na, Nd, Ni, P, Pb, Rb, S, Sc, Si, Sn, Sr, U, V, Y, Zn). European Council directives and USEPA guidelines were used to assess the water quality. The results indicate that all samples are fresh water, suitable for human consumption. All basic ions and physico-chemical parameters have average concentrations below their recommended optimum limits with the exception of electrical conductivity, for January 2007, and nitrate for October 2006 and January 2007 sampling periods. This exceedance is the result of dissolution of minerals such as calcite and dolomite that are present in the surrounding rocks and the application of fertilizers, respectively. Lead is the only element with an average value that exceeds the recommended EC guideline, while special attention should be paid to one borehole (T9) which has elevated NO 3 ? values which may pose a risk to human health.  相似文献   
93.
Predicting photochemical pollution in an industrial area   总被引:1,自引:0,他引:1  
In order to confront pollution events concerning the city of Elefsis, in the environmentally aggravated area of Thriassion Plain, an effort is undertaken to create a model forecasting maximal daily concentrations of NO(x) (NO(2)+NO), NO(2) and O(3). The data analyzed were obtained from the Bureau of Pollution Control and Environments Quality based in Elefsis. The model in question uses hourly values of the pollutants as well as meteorological data recorded at the center of the city of Elefsis from 1993 to 1999. Three fitting methods are utilized, namely ordinary least squares, piecewise, and quantile regression. The verification and reliability of the forecasting models are based on the measurements of the year 2000. The results are considered to be satisfactory, with the forecasted values following the general tendencies.  相似文献   
94.
Ecological assessments of surface water bodies are essential in order to evaluate the level of degradation in freshwater ecosystems and to address the subsequent decline in services they provide. These assessments cover multiple aspects of the aquatic environment, particularly biological elements due to their ability to respond to all pressures within an ecosystem. Such assessments can enable the identification of the multiple pressures which threaten water bodies, facilitating sustainable decisions regarding their management to be identified. Here, the design requirements of the networks which facilitate ecological assessments are presented. A river basin district in England is used as a case study to investigate the number of elements monitored, the number of failing elements and the relationship between failing elements. Findings demonstrate the value of ensuring that monitoring networks are risk based and appropriately designed to meet their objectives. This therefore requires that monitoring is not only for the communicating of compliance but also for use iteratively so that the design of monitoring networks and ultimately management can be continually improved.  相似文献   
95.
Abstract

In this paper, coming out of a broader research project on how the digital prototype can be effectively integrated in the product development process of the clothing industry, the authors investigate the relationship between Corporate Social Responsibility (CSR) and Collective Actions on Sustainability and the environmental impact of the new model of fast and accelerating fashion. Extensive research was contacted with personal interviews and analysed primary data shows how new technology solutions like Product Lifecycle Management (PLM), 3D visualisation or 3D prototyping can work with and across supply chain partners to reduce the environmental footprint of their processes. The final phase of the paper involves the conceptualisation of a new apparel product development model, encompassing various digital tools which aim at addressing fit problems, extending the useful life of clothes and reducing the environmental impact of clothing in use through design and services.  相似文献   
96.

Purpose

Perfluorooctane sulfonate (PFOS) belongs to a group of chemicals called perfluoroalkyl acids that have been extensively used in various applications such as stain and oil resistant treatments for fabrics, fire-fighting foams, and insecticides. These chemicals present an environmental and health risk being present in many samples both in wildlife and humans. In this study, we investigate the effect of PFOS on fatty acid ??-oxidation in developing chicken embryos.

Methods

Fertilized chicken eggs were exposed in ovo to PFOS at day?4 of incubation. On day?10, the eggs were dissected and livers were incubated in vitro with 3H-palmitic acid for 2?h. The media were collected, and after clean up, the amount of tritiated water was measured with liquid scintillation counting to determine the rate of palmitic acid ??-oxidation.

Results

PFOS was found to induce fatty acid ??-oxidation at doses starting from a lowest observed effect level (LOEL) of 0.1???g/g egg weight. Maximum induction of 77?% compared to control was seen at 0.3???g/g.

Conclusions

The administered doses in which effects are seen are around and even lower than the levels that can be found in wild populations of birds. General population human levels are a factor of two to three times lower than the LOEL value of this study. The environmental contamination of PFOS therefore presents a possibility of effects in wild populations of birds.  相似文献   
97.
The aim of this study was to compare two alternative toxicity assessment methods to determine wastewater toxicity and predict treatment plant process upsets. The toxicity of two synthetic organic compounds (triclosan and 4-n-nonylphenol), which are commonly detected in municipal wastewater, and municipal and industrial wastewaters with different heavy metals content were evaluated by the nitrification inhibition assay and bioluminescence toxicity test. Comparison between both assays confirmed that Vibrio fischeri is generally more sensitive than autotrophic bacteria, and, if not calibrated, the bioluminescence method tends to overestimate toxic effects on activated sludge biomass. The nitrification inhibition assay appears to predict plant process upsets more accurately. Both methods showed a significant toxicity decrease through treatment that could be partially attributed to the significant heavy metals removal obtained by primary and secondary treatment. A good correlation for the two assays was obtained, as indicated by a high correlation coefficient (r2 = 0.80).  相似文献   
98.
Two different experimental techniques employing conservative tracers to determine exfiltration losses in a sewer system are reported. Both techniques compare the in-sewer responses measured along designated indicator and reference sections to assess the level of exfiltration although with different degrees of reliability. The experimental and interpretation errors associated with a pulse dosing technique, in which Rhodamine WT is used as the single tracer, are described. The estimation of exfiltration requires the comparison of indicator and reference peaks which need to be well resolved and reproducible in order to provide realistic results. A more consistent technique involves the continuous dosing of two different tracers with the objective of producing simultaneous downstream peak tracer concentrations. Any errors due to flow variations are eliminated and the longer measurement period allows both peak and background concentrations to be more accurately determined. Rhodamine WT, Li and Br were used in different combinations over the approximately 20 min duration of each continuous dosing experiment and were found to demonstrate conservative behaviours with measured recoveries of 97.6-100.6%, 97.3-101.4% and 108.4-109.2%, respectively. The analytical problems associated with the determination of the different tracers in sewage are described and are shown to be responsible for the reduced accuracy of the results associated with the use of Br. The preferred combination of tracers is Rhodamine WT as the indicator and Li as the reference and these are shown to be capable of estimating sewer losses to an accuracy of +/-1.0% using the continuous dosing approach.  相似文献   
99.
The objective of this work was to determine the composition and production rate of medical waste from the health care facility of social insurance institute, a small waste producer in Xanthi, Greece. Specifically, produced medical waste from the clinical pathology (medical microbiology) laboratory, the X-ray laboratory and the surgery and injection therapy departments of the health facility was monitored for six working weeks. A total of 240 kg medical solid waste was manually separated and weighed and 330 L of liquid medical waste was measured and classified. The hazardous waste fraction (%w/w) of the medical solid waste was 91.6% for the clinical pathology laboratory, 12.9% for the X-ray laboratory, 24.2% for the surgery departments and 17.6% for the injection therapy department. The infectious waste fraction (%w/w) of the hazardous medical solid waste was 75.6% for the clinical pathology laboratory, 0% for the X-ray laboratory, 100% for the surgery departments and 75.6% for the injection therapy department. The total hazardous medical solid waste production rate was 64 ± 15 g/patient/d for the clinical pathology laboratory, 7.2 ± 1.6 g/patient/d for the X-ray laboratory, 8.3 ± 5.1 g/patient/d for the surgery departments and 24 ± 9 g/patient/d for the injection therapy department. Liquid waste was produced by the clinical pathology laboratory (infectious-and-toxic) and the X-ray laboratory (toxic). The production rate for the clinical pathology laboratory was 0.03 ± 0.003 L/patient/d and for the X-ray laboratory was 0.06 ± 0.006 L/patient/d. Due to the small amount produced, it was suggested that the most suitable management scheme would be to transport the hazardous medical waste, after source-separation, to the Prefectural Hospital of Xanthi to be treated with the hospital waste. Assuming this data is representative of other small medical facilities, medical waste production can be estimated for such facilities distributed around Greece.  相似文献   
100.
Cadmium levels in Europe: implications for human health   总被引:5,自引:0,他引:5  
In this study we used the Forum of European Geological Surveys geochemical baseline data to examine the distribution of cadmium (Cd) in Europe, with a particular reference to the international soil and water guideline values. The highest cadmium levels were found to occur in topsoil and to follow closely the distribution of P2O5, suggesting that the contamination was from the use of rock phosphate fertilizer in intensive arable agriculture. In terms of human health impacts, food (up to several hundred μg/day) was found as the only major route of exposure to Cd for the non-smoking general population. It appeared that low levels of chronic exposure to Cd resulted in completely different human health impacts than those high levels that had caused the ‘itai–itai’ disease. Some correlations were suggested between cadmium levels and the age-adjusted prostate or breast cancer rates distributed in the European countries under study.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号