全文获取类型
收费全文 | 74篇 |
免费 | 3篇 |
国内免费 | 7篇 |
专业分类
安全科学 | 1篇 |
废物处理 | 4篇 |
环保管理 | 2篇 |
综合类 | 18篇 |
基础理论 | 11篇 |
污染及防治 | 25篇 |
评价与监测 | 22篇 |
灾害及防治 | 1篇 |
出版年
2023年 | 1篇 |
2022年 | 3篇 |
2021年 | 1篇 |
2020年 | 1篇 |
2019年 | 2篇 |
2018年 | 2篇 |
2017年 | 1篇 |
2015年 | 2篇 |
2014年 | 4篇 |
2013年 | 5篇 |
2012年 | 5篇 |
2011年 | 4篇 |
2010年 | 1篇 |
2009年 | 4篇 |
2008年 | 4篇 |
2007年 | 6篇 |
2006年 | 2篇 |
2005年 | 6篇 |
2004年 | 4篇 |
2003年 | 2篇 |
2002年 | 1篇 |
2001年 | 4篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1997年 | 5篇 |
1996年 | 2篇 |
1992年 | 1篇 |
1991年 | 7篇 |
1990年 | 1篇 |
1985年 | 1篇 |
排序方式: 共有84条查询结果,搜索用时 78 毫秒
71.
72.
Fish scale (FS) loaded TiO2 composites were investigated as photocatalysts in degradation of Methyl Orange under solar light irradiation. Composites were prepared through sol-gel method by varying mass ratio of TiO2/FS at 90:10, 70:30 and 50:50, respectively. The catalysts prepared in this study were characterized by using XRD, SEM, FT-IR and nitrogen sorption. The effects of solar irradiation, mass ratio of TiO2/FS composites, irradiation time and catalyst loadings were studied. Synergistic effect was found in TiO2/FS of 90:10 composite which performed higher photocatalytic degradation than synthesized TiO2 under solar light irradiation. However, further increasing fish scale content in the composites reduced the photocatalytic activity drastically. Under solar light irradiation, all the catalysts in this study exhibited photocatalytic activity, except TiO2/FS of 50:50 composite that only acted as a weak biosorbent without performing any photocatalytic property. Photocatalytic degradation increased with increasing catalyst loading and irradiation time but decreased with increased of initial dye concentration. 相似文献
73.
Principal component analysis (PCA) is capable of handling large sets of data. However, lack of consistent method in data pre-treatment and its importance are the limitations in PCA applications. This study examined pre-treatments methods (log (x?+?1) transformation, outlier removal, and granulometric and geochemical normalization) on dataset of Mengkabong Lagoon, Sabah, mangrove surface sediment at high and low tides. The study revealed that geochemical normalization using Al with outliers removal resulted in a better classification of the mangrove surface sediment than that outliers removal, granulometric normalization using clay and log (x?+?1) transformation. PCA output using geochemical normalization with outliers removal demonstrated associations between environmental variables and tides of mangrove surface sediment, Mengkabong Lagoon, Sabah. The PCA outputs at high and low tides also provided to better interpret information about the sediment and its controlling factors in the intertidal zone. The study showed data pre-treatment method to be a useful procedure to standardize the datasets and reducing the influence of outliers. 相似文献
74.
A sequencing batch reactor (SBR) seeded with flocculated sludge and fed with synthetic wastewater was operated for an enhanced biological phosphorus removal (EBPR) process. Eight weeks after reactor startup, sludge granules were observed. The granules had a diameter of 0.5 to 3.0 mm and were brownish in color and spherical or ellipsoidal in shape. No significant change was observed in sludge granule size when operational pH was changed from 7 to 8. The 208-day continuous operation of the SBR showed that sludge granules were stably maintained with a sludge volume index (SVI) between 30 to 55 mL/g while securing a removal efficiency of 83% for carbon and 97% for phosphorus. Fluorescent in situ hybridization (FISH) confirmed the enrichment of polyphosphate accumulating organisms (PAOs) in the SBR. The observations of sludge granulation in this study encourage further studies in the development of granules-based EBPR process. 相似文献
75.
Robert E. Hinchee Say Kee Ong 《Journal of the Air & Waste Management Association (1995)》2013,63(10):1305-1312
An in situ test method to measure the aerobic biodegradation rates of hydrocarbons in contaminated soil is presented. The test method provides an initial assessment of bioventing as a remediation technology for hydrocarbon-contaminated soil. The in situ respiration test consists of ventilating the contaminated soil of the unsatiirated zone with air and periodically monitoring the depletion of oxygen (O2) and production of carbon dioxide (CO2) over time after the air is turned off. The test is simple to implement and generally takes about four to five days to complete. The test was applied at eight hydrocarbon-contaminated sites of different geological and climatic conditions. These sites were contaminated with petroleum products or petroleum fuels, except for two sites where the contaminants were primarily polycyclic aromatic hydrocarbons. Oxygen utilization rates for the eight sites ranged from 0.02 to 0.99 percent O2/hour. Estimated biodegradation rates ranged from 0.4 to 19 mg/kg of soil/day. These rates were similar to the biodegradation rates obtained from field and pilot studies using mass balance methods. Estimated biodegradation rates based on O2 utilization were generally more reliable (especially for alkaline soils) than rates based on CO2 production. CO2 produced from microbial respiration was probably converted to carbonate under alkaline conditions. 相似文献
76.
Lai Yoke Lee Jiang Yong Hu Say Leong Ong How Yong Ng Shih Wei Wong Yaoyu Feng Xiaolan Tan 《Water environment research》2008,80(8):725-731
The application of immunofluorescent labeling using quantum dots for detection of inactivated Cryptosporidium parvum oocysts in spiked water samples (reservoir water, treated wastewater effluent, permeate of a membrane bioreactor, and tap water) provided more consistent results compared with the organic fluorophores label. The varying degree of particles present in the different water samples (with turbidity ranging from 0.2 to 6.1 NTU) in nonconcentrated water samples had insignificant interference on the labeled counts (2-sample t-tests, p > 0.236) using the quantum dot label, while the quantum dot label provided an advantage of approximately 50% lower interference in concentrated water samples compared with the organic fluorophores label. 相似文献
77.
Endocrine disruptor contamination is an emerging issue of concern in the field of water quality engineering. In this study, a lab-scale microfiltration (MF) and reverse osmosis (RO) based water reclamation system was set up to monitor and evaluate the removal of bisphenol A (BPA), which is a known oestrogenic compound. The identification and quantification of BPA were performed by using gas chromatography coupled with mass spectrometry. It was noted that the detection method used in this study was able to achieve an average recovery ranging from 88.2 to 94.1% of BPA with standard deviations of less than 10% in different spiked samples. The detection limit of the analytical protocol was determined at 20 ng L(-1). Based on the analytical protocol, it was noted that a low level of BPA (1.18-3.04 microg L(-1)) could be detected in feed water (effluent of an activated sludge treatment system) to the dual membrane water reclamation system. The results obtained suggested that BPA could be easily chlorinated by sodium hypochlorite with a dosage of 4 to 5 mg L(-1) and a contact time of 1 to 2 min. In this lab-scale study, a satisfactory removal of BPA was readily obtained by RO and BPA was abated to an undetectable level in the product water. It was noted that the RO rejection characteristic of BPA was not sensitive to the variations in raw feed water characteristics experienced in this study. In addition, it was noted that BPA concentration present in raw feed water did not exert any significant impact on RO performance in terms of BPA rejection. The results of this study demonstrated that membrane technology could be effectively used for BPA removal. 相似文献
78.
Wei-Eng Thung Soon-An Ong Li-Ngee Ho Yee-Shian Wong Fahmi Ridwan Yoong-Ling Oon Yoong-Sin Oon Harvinder Kaur Lehl 《环境科学学报(英文版)》2018,30(4):295-300
This study demonstrated the potential of single chamber up-flow membrane-less microbial fuel cell(UFML-MFC) in wastewater treatment and power generation. The purpose of this study was to evaluate and enhance the performance under different operational conditions which affect the chemical oxygen demand(COD) reduction and power generation,including the increase of KCl concentration(MFC1) and COD concentration(MFC2). The results showed that the increase of KCl concentration is an important factor in up-flow membrane-less MFC to enhance the ease of electron transfer from anode to cathode. The increase of COD concentration in MFC2 could led to the drop of voltage output due to the prompt of biofilm growth in MFC2 cathode which could increase the internal resistance. It also showed that the COD concentration is a vital issue in up-flow membrane-less MFC.Despite the COD reduction was up to 96%, the power output remained constrained. 相似文献
79.
Kevin Spencer Adolfo W Liao Hariklea Skentou Charas YT Ong Kypros H Nicolaides 《黑龙江环境通报》2001,21(4):270-273
Maternal serum total activin-A concentration was measured in 45 pregnancies affected by trisomy 21 and 493 control unaffected pregnancies at 10–14 weeks of gestation. In the trisomy 21 pregnancies total activin-A concentration was significantly higher (1.36 MoM of the unaffected pregnancies) and in 16% of cases the level was above the 95th centile of normal. The log10 SD for the control group and the trisomy 21 group were 0.17 and 0.22, respectively. The median pregnancy associated plasma protein-A (PAPP-A) in this trisomy 21 series was 0.49 and for free β-hCG was 2.05. In the trisomy group there were significant positive associations between total activin-A and PAPP-A (0.6071) and free β-hCG (0.4255). The low median difference and the high overlap in values between trisomic and unaffected pregnancies make total activin-A of little practical use in first-trimester screening for trisomy 21. Copyright © 2001 John Wiley & Sons, Ltd. 相似文献
80.
C. P. Ong M. R. Khan S. F. Y. Li H. K. Lee 《Environmental monitoring and assessment》1991,19(1-3):35-46
This paper describes the use of the overlapping resolution mapping procedure to optimize the separation of priority pollutants by isocratic, reversed-phase high-performance liquid chromatography. Three classes of pollutants are considered: polycyclic aromatic hydrocarbons, substituted phenols and phthalate esters. The procedure requires only seven chromatographic runs for each set of pollutants before an optimized mobile phase composition is derived which can satisfactorily resolve all the components in the respective mixtures of pollutants. The main advantage of such a systematic scheme to optimize mobile phase compositions is an improvement in method development times compared to conventional techniques. Another benefit is that expenditures on solvents are reduced. 相似文献