The concentrations of trace metals (Cd, Pb, Cu, Cr, Fe, Ni, Zn and Co) were studied in soil profiles of eight municipal waste
dump sites in Warri metropolis. The results indicate that concentrations of trace metals varied widely among the different
dumpsites and decreased with depths in a studied soil profile. The accumulation pattern for the heavy metals in the soil profiles
follows the order: Fe > Pb > Mn > Co > Cr > Zn > Ni > Cu > Cd. The concentrations of metals found in these sites was below
the Canadian remediation criteria for land for agricultural, residential and commercial/industrial purposes except for the
cadmium levels in some sites that exceeded criterion values for agricultural and residential. In such sites, remedial actions
are required before any form of chosen development can take place. The levels of heavy metals found in these dump sites were
higher than that of the control site. The examined metals showed no significant correlation with soil physicochemical properties
at the surface horizon, which is suggestive evidence that these metals arise from anthropogenic input. 相似文献
The main aim of this study is the integrated assessment of a proposed Waste-to-Energy facility that could contribute in the Municipal Solid Waste Management system of the Region of Central Greece. In the context of this paper alternative transfer schemes for supplying the candidate facility were assessed considering local conditions and economical criteria. A mixed-integer linear programming model was applied for the determination of optimum locations of Transfer Stations for an efficient supplying chain between the waste producers and the Waste-to-Energy facility. Moreover different Regional Waste Management Scenarios were assessed against multiple criteria, via the Multi Criteria Decision Making method ELECTRE III. The chosen criteria were total cost, Biodegradable Municipal Waste diversion from landfill, energy recovery and Greenhouse Gas emissions and the analysis demonstrated that a Waste Management Scenario based on a Waste-to-Energy plant with an adjacent landfill for disposal of the residues would be the best performing option for the Region, depending however on the priorities of the decision makers. In addition the study demonstrated that efficient planning is necessary and the case of three sanitary landfills operating in parallel with the WtE plant in the study area should be avoided. Moreover alternative cases of energy recovery of the candidate Waste-to-Energy facility were evaluated against the requirements of the new European Commission Directive on waste in order for the facility to be recognized as recovery operation. The latter issue is of high significance and the decision makers in European Union countries should take it into account from now on, in order to plan and implement facilities that recover energy efficiently. Finally a sensitivity check was performed in order to evaluate the effects of increased recycling rate, on the calorific value of treated Municipal Solid Waste and the gate fee of the candidate plant and found that increased recycling efforts would not diminish the potential for incineration with energy recovery from waste and neither would have adverse impacts on the gate fee of the Waste-to-Energy plant. In general, the study highlighted the need for efficient planning in solid waste management, by taking into account multiple criteria and parameters and utilizing relevant tools and methodologies into this context. 相似文献
Activated (AC-PW) and non-activated (C-PW) carbonaceous materials were prepared from the Brazilian-pine fruit shell (Araucaria angustifolia) and tested as adsorbents for the removal of reactive orange 16 dye (RO-16) from aqueous effluents. The effects of shaking time, adsorbent dosage and pH on the adsorption capacity were studied. RO-16 uptake was favorable at pH values ranging from 2.0 to 3.0 and from 2.0 to 7.0 for C-PW and AC-PW, respectively. The contact time required to obtain the equilibrium using C-PW and AC-PW as adsorbents was 5 and 4 h at 298 K, respectively. The fractionary-order kinetic model provided the best fit to experimental data compared with other models. Equilibrium data were better fit to the Sips isotherm model using C-PW and AC-PW as adsorbents. The enthalpy and entropy of adsorption of RO-16 were obtained from adsorption experiments ranging from 298 to 323 K. 相似文献
Abstract: Systematic conservation assessment (an information‐gathering and prioritization process used to select the spatial foci of conservation initiatives) is often considered vital to conservation‐planning efforts, yet published assessments have rarely resulted in conservation action. Conservation assessments may lead more directly to effective conservation action if they are reoriented to inform conservation decisions. Toward this goal, we evaluated the relative priority for conservation of 7 sites proposed for the first forest reserves in the Union of the Comoros, an area with high levels of endemism and rapidly changing land uses in the western Indian Ocean. Through the analysis of 30 indicator variables measured at forest sites and nearby villages, we assessed 3 prioritization criteria at each site: conservation value, threat to loss of biological diversity from human activity, and feasibility of reserve establishment. Our results indicated 2 sites, Yiméré and Hassera‐Ndrengé, were priorities for conservation action. Our approach also informed the development of an implementation strategy and enabled an evaluation of previously unexplored relations among prioritization criteria. Our experience suggests that steps taken to ensure the closer involvement of practitioners, include a broader range of social data, encourage stakeholder participation, and consider the feasibility of conservation action can improve the relevance of assessments for conservation planning, strengthen the scientific basis for conservation decisions, and result in a more realistic evaluation of conservation alternatives.相似文献
Indoor sources have been identified as a major contributor to the increase of particle concentration in indoor environments. The work presented here is a study of the characteristics of particulate matter number size distribution and mass concentration under controlled indoor activities in a laboratory room. The objective is to characterize particulate matter concentrations indoors resulted under the influence of specific sources. Measurements were performed in an empty laboratory (period September–October 2006) using a GRIMM SMPS+C system (particle size range between 11.1 and 1083.3 nm), a DustTrak Aerosol Monitor (TSI) and a P-Trak Ultrafine Particle Counter (TSI). The studied indoor activities included candle burning, hot plate heating, water boiling, onion frying, vacuuming, hair drying, hair spraying, smoking and burning of incense stick. The AMANpsd computer algorithm was used to evaluate the modal structure of measured particle number size distribution data. Furthermore, the change of the particle number size distribution shape under the influence of different emission sources was studied versus time. Finally the particle emission rates were computed. High particle number concentrations were observed during smoking, onion frying, candle burning and incense stick burning. The highest particle mass concentrations were measured during smoking and hair spraying. The shift of the particle size distribution to larger diameters suggests the presence of strong coagulation effect during candle burning, incense stick burning, smoking and onion frying. The size distribution was mainly bimodal during onion frying and candle burning, whereas the size distribution remained unimodal during incense stick burning and smoking experiments. 相似文献
Monitoring of body burden of toxic elements is usually based on analysis of concentration of particular elements in blood, urine and/or hair. Analysis of these matrices, however, predominantly reflects short- or medium-term exposure to trace elements or pollutants. In this work, urinary stones were investigated as a matrix for monitoring long-term exposure to toxic and essential elements. A total of 431 samples of urinary calculi were subjected to mineralogical and elemental analysis by infrared spectroscopy and inductively coupled plasma mass spectrometry. The effect of mineralogical composition of the stones and other parameters such as sex, age and geographical location on contents of trace and minor elements is presented. Our results demonstrate the applicability of such approach and confirm that the analysis of urinary calculi can be helpful in providing complementary information on human exposure to trace metals and their excretion. Analysis of whewellite stones (calcium oxalate monohydrate) with content of phosphorus <0.6 % has been proved to be a promising tool for biomonitoring of trace and minor elements.
The spatial and temporal variations of some trace metals in the surface sediments of Cochin Estuary were analyzed along with their geochemical associations to identify the possible sources, bioavailability and the health risks posed by them. The dominance of kaolinite and suggested that clay minerals distribution is influenced by sediment sorting. Total metal analysis revealed enrichment for Cd, Pb and Zn due to anthropogenic activities. The speciation analysis established that notwithstanding the large availability, carbonate as well as organic and sulfides bound fractions showed negligible associations with most of the metals. Hydrous Fe–Mn oxides appeared to play a major role in controlling the fate and transport of these metals in the sediments of Cochin Estuary. Lower contribution of the residual fractions for Cd (21%–26%), Pb (<60%) and Zn (24%–42%) indicated an obvious increase of other geochemical fractions. Risk assessment analysis revealed that regardless of total concentration, none of the analyzed metals were at safe levels in the estuary as appreciable percentages were found to be associated with mobile geochemical forms. The speciation study conspicuously established that the metals originating from non-geogenic sources are largely associated with the labile fractions and hence are more detrimental to the aquatic biota. 相似文献
Accurate trend estimates are necessary for understanding which species are declining and which are most in need of conservation action. Imperfect species detection may result in unreliable trend estimates because this may lead to the overestimation of declines. Because many management decisions are based on population trend estimates, such biases could have severe consequences for conservation policy. We used an occupancy‐modeling framework to estimate detectability and calculate nationwide population trends for 14 Swiss amphibian species both accounting for and ignoring imperfect detection. Through the application of International Union for Conservation of Nature Red List criteria to the different trend estimates, we assessed whether ignoring imperfect detection could affect conservation policy. Imperfect detection occurred for all species and detection varied substantially among species, which led to the overestimation of population declines when detectability was ignored. Consequently, accounting for imperfect detection lowered the red‐list risk category for 5 of the 14 species assessed. We demonstrate that failing to consider species detectability can have serious consequences for species management and that occupancy modeling provides a flexible framework to account for observation bias and improve assessments of conservation status. A problem inherent to most historical records is that they contain presence‐only data from which only relative declines can be estimated. A move toward the routine recording of nonobservation and absence data is essential if conservation practitioners are to move beyond this toward accurate population trend estimation. 相似文献