全文获取类型
收费全文 | 105篇 |
免费 | 0篇 |
国内免费 | 5篇 |
专业分类
安全科学 | 6篇 |
废物处理 | 25篇 |
环保管理 | 13篇 |
综合类 | 16篇 |
基础理论 | 12篇 |
污染及防治 | 31篇 |
评价与监测 | 2篇 |
社会与环境 | 5篇 |
出版年
2023年 | 2篇 |
2022年 | 1篇 |
2021年 | 1篇 |
2019年 | 3篇 |
2018年 | 5篇 |
2017年 | 5篇 |
2016年 | 6篇 |
2015年 | 6篇 |
2014年 | 5篇 |
2013年 | 8篇 |
2012年 | 5篇 |
2011年 | 6篇 |
2010年 | 10篇 |
2009年 | 8篇 |
2008年 | 9篇 |
2007年 | 10篇 |
2006年 | 2篇 |
2005年 | 3篇 |
2004年 | 7篇 |
2003年 | 1篇 |
2002年 | 2篇 |
2000年 | 2篇 |
1994年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
排序方式: 共有110条查询结果,搜索用时 62 毫秒
61.
Dechlorination and destruction of PCDDs/PCDFs in fly ashes from municipal solid waste incinerators by low temperature thermal treatment 总被引:2,自引:0,他引:2
Dechlorination and destruction characteristics of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) in fly ashes from commercial-scale municipal solid waste incinerators by low temperature thermal treatment using a laboratory-scale heating system were investigated. Experiments were carried out in reducing atmosphere at temperatures of 300 degrees C, 450 degrees C and 600 degrees C respectively, for the treatment time of 1h and 3h. Concentrations of PCDDs/PCDFs in raw fly ashes ranged from 35.5 to 107.3 microg kg(-1) (1.5-3.4 microg TEQ kg(-1)) and treated fly ashes ranged from 0.34 to 45.3 microg kg(-1) (0.012-1.63 microg TEQ kg(-1)). Concentrations of PCDDs/PCDFs in fly ashes treated at the different temperatures and times were observed to decrease with increase of treatment temperature and time by dechlorination or destruction. The distribution of octa- and hepta-chlorinated congeners were decreased and tetra-, penta- and hexa-chlorinated congeners were increased at 300 degrees C and 450 degrees C, but the distribution of octa- and hepta-chlorinated congeners were increased and tetra-, penta- and hexa-chlorinated congeners were again decreased at 600 degrees C. Total destruction efficiencies of PCDDs/PCDFs in fly ashes showed above 95% at the treatment temperature of 450 degrees C for 3h. However, removal efficiency of each congener in fly ashes varied, especially, 2,3,7,8-TeCDD and 1,2,3,7,8-PeCDD in fly ash A increased. And the dechlorination and destruction characteristics of PCDDs/PCDFs in fly ash A and B was different due to difference in contents of Ca-compounds and metal oxides such as CuO and PbO in fly ashes. 相似文献
62.
S. Niggol Seo 《Mitigation and Adaptation Strategies for Global Change》2013,18(7):1019-1034
This paper refines the spatial resolution and spillover effects of a micro-econometric analysis of adaptation of agricultural portfolios to climate change using the Global Positioning System (GPS). From the household surveys collected across South America by the World Bank, the GPS recordings of exact farm locations such as latitude, longitude, and altitude are matched with high resolution grid cell climate data from the Climate Research Unit as well as geographically referenced soils and geography data from the Food and Agriculture Organization. The choice of agricultural systems at the farm level is estimated using spatial Logit model and the conditional land value is estimated for each system of agriculture after correcting for selection bias and spatial spillovers. Future choices and land values are simulated using the fine resolution climate scenarios by the UKMO (United Kingdom Meteorological Office) and GISS (Goddard Institute for Space Studies). This paper finds that, under the UKMO HadGEM1 (Hadley Center Global Environmental Model 1) scenario by around 2060, the choices of the specialized systems are expected to fall, but the mixed system would increase. The land value of the crops-only falls by 29 %, but the mixed system land value falls only by 12 %. Under a milder GISS ER (ModelE-R) scenario, the land value of the mixed system increases by 6 %. With full adaptations of agricultural systems, the expected land value falls by 17 %. Without adaptations, the damage increases. This paper demonstrates that adaptation behaviors can be best studied by a fine resolution micro-econometric analysis of agricultural portfolios using the GPS reference. 相似文献
63.
64.
Zhongkun M Junmin Jeon Sangchai Kim Sangchul Jung Woobum Lee Seonggyu Seo 《环境科学学报(英文版)》2012,24(10):1785-1789
In this study,the amounts of odorous carbonyl compounds(OCCs) including acetaldehyde(Acet-A),propionaldehyde(Pron-A),butylaldehyde(Buty-A),iso-valeric aldehyde(Iso-Vale-A) and n-valeric aldehyde(N-Vale-A) emitted from a fishery industrial complex near the exhibition facilities of "Expo 2012 Yeosu Korea" were measured.Acet-A was found to be the most abundant OCC,and the total concentrations of the OCCs were the highest in the summer.However,due to vehicular exhaust and photochemical reactions,the concentrations of some of the OCCs presented their highest levels in the fall.A significant correlation between Acet-A and Buty-A was found at the major fishery facilities(r = 0.816,p = 1.87E-15,n = 60) and at the border areas(r = 0.809,p = 3.40E-12,n = 48) of this fishery industrial complex.The concentrations of OCCs at the border areas were not worse than those at the urban areas in other places,indicating that the concentrations of ambient OCCs at the border areas were not greatly influenced by manmade activities. 相似文献
65.
66.
Moonkyung Chung Min Woo Seo Kang Suk Kim Jun Boum Park 《Waste management & research》2006,24(3):250-259
Geosynthetic liner systems are generally installed in landfill sites to prevent toxic leachate from escaping into the adjoining environment by utilizing their impervious characteristics. Therefore, it is important to protect the geomembrane from being damaged or destroyed during all phases of landfilling, namely landfill construction, waste tipping and landfill closure. This paper presents firstly the observed performance of a geomembrane liner from a landfill site where the geomembrane liner was installed on the slopes of a Korean landfill; and secondly the results of an inclined board laboratory test. Two types of experiments were conducted to identify the protecting effect of the overlaying geosynthetic on the geomembrane liners. At a testing landfill site, the slope consisted of three different sub-inclines and two 2-m-wide intermediate levels. The sub-inclines were each 8 m in vertical height and their angle of inclination was 1: 1.5 (vertical: horizontal). The reported observations were made for a time period of approximately 1 year, until the landfill was filled with wastes to the top of the uppermost slope. In addition, inclined board laboratory tests were carried out. During the inclined board test, a base table is inclined slowly and steadily until the block located on the base table starts to slide, when the tension and displacements of two geosynthetics, namely the geomembrane liner and protecting geotextile, are measured. In conclusion, test results showed that the down-drag force generated by waste accumulation and sliding of upper material was to a large extent dissipated through the elongation of the protecting geosynthetic overlying the geomembrane and thus was not transferred to the geomembrane. Unless the protecting geosynthetic undergoes structural failure, this stress relaxation phenomenon continues to occur so that the magnitude of tensile force to be applied on the geomembrane remains marginal. 相似文献
67.
68.
69.
S. H. Park E. J. Kim T. H. Yun J. H. Lee C. K. Kim Y. H. Seo S. A. Oh S. S. Choi S. J. Cho M. S. Kim G. Y. Han M. Y. Kim H. S. Jeong D. S. Cheon H. S. Kim 《Food and environmental virology》2010,2(2):69-73
Waterborne outbreaks of enteric viruses are a major public health concern. The present study has been carried out to assess the presence of enteric viruses responsible for human acute gastroenteritis (AGE) in groundwater intended for drinking and produce washing. In total, 62 samples from groundwater for drinking and produce washing collected from Dec 2007 to Dec 2008 in Seoul were tested for enteric viruses using conventional RT–PCR, ELISA, and real-time RT–PCR. Our results showed that enteric viruses were detected in 7 (8.8%) groundwater samples. Rotaviruses were detected in 3 (4.8%) of the samples by ELISA; human adenoviruses were detected in 2 (3.2%) of the samples by ELISA; and nested RT–PCR detected noroviruses in 2 (3.2%) of the samples. In one of the groundwater sample, the norovirus RNA was detected by conventional RT–PCR which was confirmed positive by real-time RT–PCR. Additionally, real-time RT–PCR successfully detected norovirus RNA in five out of 62 water samples (8.1%). The data demonstrate that real-time RT–PCR will be useful as a rapid and sensitive method for detecting norovirus in water samples. Phylogenetic analysis revealed that the noroviruses detected in two of the groundwater samples belonged to GII-4. These studies can provide important information for the prevalence of enteric viruses in Korean groundwater. 相似文献
70.
Deepak Pudasainee Jeong-Hun Kim Yong-Chil Seo 《Atmospheric environment (Oxford, England : 1994)》2009,43(39):6254-6259
Regulatory control of mercury emission from anthropogenic sources has become a global concern in the recent past. Coal-fired power plants are one of the largest sources of anthropogenic mercury emission into the atmosphere. This paper summarizes the current reducing trend of mercury emission as co-beneficial effect by more stringent regulation changes to control primary air pollutants with introducing test results from the commercial coal-fired facilities and suggesting a guideline for future regulatory development in Korea. On average, mercury emission concentrations ranged 16.3–2.7 μg Sm?3, 2.4–1.1 μg Sm?3, 3.1–0.7 μg Sm?3 from anthracite coal-fired power plants equipped with electrostatic precipitator (ESP), bituminous coal-fired power plants with ESP + flue gas desulphurization (FGD) and bituminous coal-fired power plants with selective catalytic reactor (SCR) + cold side (CS) ? ESP + wet FGD, respectively. Among the existing air pollution control devices, the best configuration for mercury removal in coal-fired power plants was SCR + CS ? ESP + wet FGD, which were installed due to the stringent regulation changes to control primary air pollutants emission such as SO2, NOx and dust. It was estimated that uncontrolled and controlled mercury emission from coal-fired power plants as 10.3 ton yr?1 and 3.2 ton yr?1 respectively. After the installation of ESP, FGD and SCR system, following the enforcement of the stringent regulation, 7.1 ton yr?1 of mercury emission has been reduced (nearly 69%) from coal-fired power plants as a co-benefit control. Based on the overall study, a sample guideline including emission limits were suggested which will be applied to develop a countermeasure for controlling mercury emission from coal-fired power plants. 相似文献