首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   71篇
  免费   1篇
废物处理   3篇
环保管理   3篇
综合类   7篇
基础理论   11篇
污染及防治   23篇
评价与监测   19篇
社会与环境   6篇
  2023年   2篇
  2022年   3篇
  2021年   3篇
  2019年   2篇
  2018年   10篇
  2017年   5篇
  2016年   4篇
  2015年   1篇
  2014年   1篇
  2013年   11篇
  2012年   1篇
  2011年   3篇
  2010年   2篇
  2009年   3篇
  2007年   1篇
  2006年   3篇
  2004年   3篇
  2003年   5篇
  2002年   3篇
  2000年   1篇
  1985年   1篇
  1965年   1篇
  1964年   2篇
  1955年   1篇
排序方式: 共有72条查询结果,搜索用时 15 毫秒
51.
Investigations were conducted into the treatment of effluents produced during manufacturing processes at both a chemicals production facility and a paint manufacturing facility. A comparison of costs of wastewater treatment at both facilities was also performed. The untreated effluents from both facilities were high in biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS). In addition, the effluents from the two facilities deviated significantly in dissolved oxygen (DO) content and pH levels. However, both facilities ultimately released treated wastewater with allowable amounts or levels of BOD, COD, TDS, DO, and pH as permitted by the Department of the Environment, Ministry of Environment and Forests, Bangladesh (DOE). The effluent treatment plants (ETP) at both facilities contained combinations of chemical and biological treatment processes. The treatment processes used at the chemicals production facility and at the paint manufacturing facility were continuous and semi‐batch processes, respectively. The biological treatment section of the ETP at the chemicals production facility has both anaerobic and aerobic units, while the paint manufacturing facility has only an aerobic unit. Annual installation and operation costs of the ETP at the chemicals production facility was Bangladeshi Taka (Tk) 1,300,000 ($16,667 US dollars) and Tk 800,000 ($10,257), respectively. The annual installation and operation costs of the ETP at the paint manufacturing facility were Tk 3,050,000 ($39,103) and Tk 6,200,000 ($79,488), respectively.  相似文献   
52.
The study has analysed the effects of various factors on hydroelectric power generation potential to include climate change/variability, water demand, and installation of proposed hydroelectric power schemes in the Zambezi River Basin. An assessment of historical (1970–2000) power potential in relation to climate change/variability at existing hydro electric power schemes(Cahora Bassa, Kariba, Kafue Gorge and Itezhi-Tezhi) in the Zambezi River Basin was conducted. The correlation of hydroelectric power potential with climate change/variability aimed at observing the link and extent of influence of the latter on the former was investigated. In order to predict the future outlook of hydro electric power potential, General Circulation Models (GCM) were used to generate projected precipitation. The monthly simulated precipitation was extracted from the GCM for every sub basin and used to compute future precipitation. Further, future water demand in the sub basins of the Zambezi River Basin were estimated based on the respective population growth rate in each sub basin. Subsequently, water balance model, with projected precipitation and water demand input was used to determine projected run-offs of sub basins of the Zambezi River Basin. .Based on the projected run-offs of sub basins, reservoir storage capacities at existing hydro electric power schemes were estimated. The baseline assessment revealed a strong relationship between hydroelectric power potential and climate change/variability. The study also revealed that the main climate and other risks associated with current and future hydro electric power generation include projected dry years, floods and increasing water demand. The results indicate that the hydroelectric power potential has a tendency towards gradual reduction in its potential in all existing and proposed hydroelectric power schemes owing to climate change and increasing water demand.  相似文献   
53.
The paper describes differential tolerance of two fresh water crustaceans Mesocyclops hyalinus and Allodiaptomus satanus to 60Co gamma radiation. Mesocyclops hyalinus is dominant species at site 1, near a Thermal Power Plant at Kolaghat East Midnapore where fly ash deposition is a regular phenomenon. Allodiaptomus satanus is dominant species at site 2 at Kolkata, Ballygung where anthroponotic activities are more pronounced. M. hyalinus is naturally exposed to more stressful situation than A. satanus as revealed by comparing the hydrological parameters of the two habitats. Experimental exposure to ionizing radiation resulted in differential changes in viability morphology and antioxidant enzyme activities in the two selected species. Survival experiments showed greater tolerance of M. hyalinus compared to A. satanus up to 8Gy (absorbed dose) after which if showed drastic fail in survival. More pronounced morphological changes were observed in A. satanus as compared to that in M. hyalinus. The pattern of changes in antioxidant enzyme activity is distinctly opposite in the two radiation exposed species. While in M. hyalinus stimulation in activity of both CAT (excepting at 10Gy absorbed dose) and SOD was observed A. satanus showed decrease in activity of both the enzymes when compared to their unirradiated counterparts.  相似文献   
54.
Environmental Chemistry Letters - Fresh food products such as fruits and vegetables are usually degrading fast after harvest, notably due to the production of ethylene, an aging hormone, by the...  相似文献   
55.

Background, aim and scope  

Soil organic matter (SOM) is known to increase with time as landscapes recover after a major disturbance; however, little is known about the evolution of the chemistry of SOM in reconstructed ecosystems. In this study, we assessed the development of SOM chemistry in a chronosequence (space for time substitution) of restored Jarrah forest sites in Western Australia.  相似文献   
56.
Environmental Science and Pollution Research - The world faces tremendous challenges and environmental crises due to the rising strength of wastewater. The conventional technologies fail to achieve...  相似文献   
57.
Leachate and groundwater samples were collected from Gazipur landfill-site and its adjacent area to study the possible impact of leachate percolation on groundwater quality. Concentration of various physico-chemical parameters including heavy metal (Cd, Cr, Cu, Fe, Ni, Pb and Zn) and microbiological parameters (total coliform (TC) and faecal coliform (FC)) were determined in groundwater and leachate samples. The moderately high concentrations of Cl, NO 3, SO2− 4, NH+ 4, Phenol, Fe, Zn and COD in groundwater, likely indicate that groundwater quality is being significantly affected by leachate percolation. Further they proved to be as tracers for groundwater contamination. The effect of depth and distance of the well from the pollution source was also investigated. The presence of TC and FC in groundwater warns for the groundwater quality and thus renders the associated aquifer unreliable for domestic water supply and other uses. Although some remedial measures are suggested to reduce further groundwater contamination via leachate percolation, the present study demand for the proper management of waste in Delhi.  相似文献   
58.
Public transport in Delhi was amended by the Supreme Court of India to use Compressed Natural Gas (CNG) instead of diesel or petrol. After the implementation of CNG since April 2001, Delhi has the highest fraction of CNG-run public vehicles in the world and most of them were introduced within 20 months. In the present study, the concentrations of various criteria air pollutants (SPM, PM10, CO, SO2 and NOx) and organic pollutants such as benzene, toluene, xylene (BTX) and polycyclic aromatic hydrocarbons (PAHs) were assessed before and after the implementation of CNG. A decreasing trend was found for PAHs, SO2 and CO concentrations, while the NOx level was increased in comparison to those before the implementation of CNG. Further, SPM, PM10, and BTX concentrations showed no significant change after the implementation of CNG. However, the BTX concentration demonstrated a clear relation with the benzene content of gasoline. In addition to the impact of the introduction of CNG the daily variation in PAHs levels was also studied and the PAHs concentrations were observed to be relatively high between 10 pm to 6 am, which gives a proof of a relation with the limited day entry and movement of heavy vehicles in Delhi.  相似文献   
59.
Today, environment pollution control is a matter of concern, everybody is willing to make a product that should be ecofriendly. Nowadays, water resources are full of untreated waste materials, discharge of hazardous and toxic dyes coming from textile and other chemical industries. These environmental hazards are difficult to remove by commercial water treatment plans, thus we need something that would present an efficient means for removal of these hazards. In this research paper, we have synthesize silver nanoparticle in a green way by using aqueous extract of Allium cepa (onion), and further these silver nanoparticle were tested for the catalytic degradation of various dyes by UV/Visible spectroscopy and silver nanoparticle showed reduction in dyes intensity after a particular period of incubation time. SEM and TEM, Particle size and Zeta potential analysis was done to analyze the surface morphology, particle size range and stability of the silver nanoparticle. Greenly synthesized silver nanoparticle was found to be spherical in shape, having particle size value ranged from 50 to 100 nm with a zeta potential value of ?29 mV. An EDX spectroscopy method was used to confirm the presence of silver nanoparticle in the synthesized material. An X-ray crystallography was done to ensure the crystallinity of the silver nanoparticle. Further an ATR-FTIR was performed to confirm the capping of the silver nanoparticle with the phenolic group of the onion. All these study emphasized that silver nanoparticle capped with onion (AgNPs@Ac) is the excellent catalyst for the reduction of hazardous and toxic dyes as well as they serve best purpose of the eco-friendly approach.  相似文献   
60.
A comprehensive attempt has been made to evaluate the diurnal and spatial pattern of CO2 exchange between the atmosphere and water along the estuarine track of Indian Sundarbans during the two summer months, April and May, 2011. Rigorous field observations were carried out which included the hourly measurements of total alkalinity, pH, fugacity of CO2 in ambient air and water surface, dissolved oxygen, and chlorophyll a. The estuarine water was found rich in total alkalinity and was oversaturated with CO2 throughout the diurnal cycle in the two stations situated at the inner and middle estuary, respectively, whereas an entirely reverse situation was observed in the outer fringes. The fugacity of CO2 in water ranged from 152 to 657 μatm during the study period. The percentage of over-saturation in inner and middle estuary varied from 103 to 168 and 103 to 176 %, respectively, whereas the degree of under-saturation in the outer estuary lied between 40 and 99 %. Chlorophyll a concentrations were found higher in the outer estuary (12.3?±?2.2 mg?m?3) compared to the middle (6.4?±?0.6 mg?m?3) and inner parts (1.6?±?0.2 mg?m?3), followed by a similar decreasing pattern in nutrient availability from the outer to inner estuary. The sampling stations situated at the inner and middle estuary acted as a net source of 29.69 and 23.62 mg?CO2?m?2 day?1, respectively, whereas the outer station behaved as a net sink of ?33.37 mg?CO2 m?2 day?1. The study of primary production and community respiration further supports the heterotrophic nature of the estuary in the inner region while the outer periphery was marked by dominant autotrophic character. These contrasting results are in parity with the source characters of many inner estuaries and sinking characters of the outer estuaries situated at the distal continental shelf areas.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号