首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   197篇
  免费   4篇
  国内免费   18篇
安全科学   11篇
废物处理   16篇
环保管理   20篇
综合类   33篇
基础理论   31篇
环境理论   1篇
污染及防治   87篇
评价与监测   11篇
社会与环境   5篇
灾害及防治   4篇
  2023年   1篇
  2022年   3篇
  2019年   2篇
  2018年   9篇
  2017年   14篇
  2016年   8篇
  2015年   8篇
  2014年   10篇
  2013年   21篇
  2012年   13篇
  2011年   16篇
  2010年   13篇
  2009年   11篇
  2008年   21篇
  2007年   16篇
  2006年   13篇
  2005年   11篇
  2004年   11篇
  2003年   7篇
  2002年   3篇
  2001年   2篇
  1994年   2篇
  1991年   1篇
  1978年   1篇
  1970年   1篇
  1969年   1篇
排序方式: 共有219条查询结果,搜索用时 31 毫秒
121.
This study evaluated the prospective damage costs of PM(2.5) inhalation. We performed a health risk assessment based on an exposure-response function to estimate the annual population risk in the Seoul metropolitan city, Korea. Also, we estimated a willingness-to-pay (WTP) amount for reducing the mortality rate in order to evaluate a statistical life value. We combined the annual population risk and the value-of-statistical-life to calculate the damage cost estimate. In the health risk assessment, we applied the PM(2.5) relative risk to evaluate the annual population risk. We targeted an exposure population of 5,401,369 persons who were over the age of 30. Using a Monte-Carlo simulation for uncertainty analysis, we estimated that the population risk of PM(2.5) inhalation during a year in Seoul is 2181 premature deaths for acute exposure and 18,510 premature deaths for chronic exposure. The monthly average WTP for 5/1000 mortality reduction over ten years is $20.20 USD (95% C.I: $16.60-24.50) and the implied value-of-statistical-life (VSL) is $485,000 USD (95% C.I: $398,000-588,000). The damage cost estimate due to risk from PM(2.5) inhalation in Seoul is about $1057 million USD per year for acute exposure, and $8972 million USD per year for chronic exposure. It is important to note that this cost estimate does not reflect all health damage cost estimates in this urban area. This recommendation is a model for evaluating a mortality risk reduction and as such we must re-evaluate an integrated application of morbidity risk.  相似文献   
122.

Bedrock groundwaters in Geumsan County, Korea, were surveyed to investigate the distribution and geochemical behaviors of arsenic and fluoride, mobilized through geogenic processes. The concentrations were enriched up to 113 μg/L for arsenic and 7.54 mg/L for fluoride, and 16% of 150 samples exceeded World Health Organization drinking water guidelines for each element. Simple Ca-HCO3 groundwater types and positive correlations with pH, Ca, SO4, and HCO3 were characteristics of high (>10 μg/L) As groundwaters. The oxidation reaction of sulfide minerals in metasedimentary rocks and locally mineralized zones seems to be ultimately responsible for the existence of arsenic in groundwater. Desorption process under high pH conditions may also control the arsenic mobility in the study area. High (>1.5 mg/L) F groundwaters were found in the Na-HCO3 type and with greater depth. Fluoride seemed to be enriched by deep groundwater interaction with granitic rocks, and continuous supply to shallow Ca-HCO3-type groundwater kept the concentration high. In the study area, drinking water management should include periodic As and F monitoring in groundwater.

  相似文献   
123.
124.
爆炸物污染土壤中2,4-DNT和2,6-DNT的生物降解中试研究   总被引:1,自引:0,他引:1  
设计采用包括土壤生物降解、反硝化以及循环混合系统构成的中试流程,模拟原位生物修复工艺,依靠污染土壤自身的生物降解过程去除2,4-二硝基甲苯(2,4-DNT) 和2,6-二硝基甲苯(2,6-DNT).结果表明,即使在温度较低的条件下(8~15℃),2,4-DNT 和2,6-DNT仍可以被完全去除.两者虽然属于同分异构体,但前者的生物降解速率大大高于后者.系统可以维持自身的碱度平衡和保证无机营养供应,无需调节或补充;反硝化能够正常进行,从而防止亚硝酸根在系统内积累抑制DNT生物降解,但要彻底去除亚硝酸根及硝酸根,需要外加碳源.  相似文献   
125.
126.
To evaluate the effect of handle design characteristics on subjective ratings and pulling forces, meat-hook handles with various handle shapes, sizes, and hook positions were tested in a pulling task. Finger and phalange force data measured by force sensitive resistors and subjective ratings of discomfort were also evaluated. Generally subjects preferred 37-mm double frustum, 30-mm oval handles followed by 30-mm double frustum handles, 37-mm oval, and 45-mm double frustum handles. In the analyses of total pulling force, 37- and 45-mm double frustum handles showed less required pulling force than the others. The averages of finger force contributions to the total pulling force were 27.2, 28.1, 23.9, and 20.8% in order from index to little fingers. The average of phalange force contributions were 28.8, 33.6, and 37.6% for the distal, middle, and proximal phalanges, respectively. The findings illustrate that the pulling finger forces and subjective discomfort ratings were related to the handle shape as well as handle size.  相似文献   
127.
128.
Many studies have been recently reported that veterinary antibiotics released into the environment have a detrimental effect on humans such as the occurrence of antibiotic-resistant bacteria. However, only limited information is available regarding to the release of antibiotics in environmental compartments in Korea. Objectives of this study were to evaluate the concentrations of antibiotics in water, sediment, and soil adjacent to a composting facility in Korea and to determine the dilution effects of antibiotics when released into the environment. Seven antibiotics of chlortetracycline, oxytetracycline, tetracycline, sulfamethazine, sulfamethoxazole, sulfathiazole, and tylosin were evaluated by high-performance liquid chromatography?Ctandem mass spectrometry following pretreatment using solid-phase extraction to clean the samples. Results showed that the highest concentration of each antibiotic in both aqueous and solid samples was detected from a site adjacent to the composting facility. We also found that the studied water, sediment, and soil samples are contaminated by veterinary antibiotics throughout comparison with studies from other countries. However, relatively lower concentrations of each antibiotic were observed from the rice paddy soil located at the bottom of the water stream. Further research is necessary to continuously monitor the antibiotics release into ecosystems, thereby developing an environmental risk assessment.  相似文献   
129.
A prediction model based on the partial least squares of the multivariate statistical analysis methods was developed for the flash point (FP) of binary liquid mixtures. Estimation of the FP of flammable substances is important for safety measures in industrial processes. Since experimental FP data of liquid mixtures are scarce in the literature, there have been many researches to estimate the FP of liquid mixtures using physicochemical laws. In this study, the partial least squares (PLS) method using experimental data was used as a prediction model of the FP of binary liquid mixtures. The FPs predicted from the PLS method were also compared to results from the existing calculating methods using physicochemical laws such as Raoult's law and the Van Laar equation.  相似文献   
130.
The nitrogen oxides (NOx) reduction technology by combustion modification which has economic benefits as a method of controlling NOx emitted in the combustion process, has recently been receiving a lot of attention. Especially, the moderate or intense low oxygen dilution (MILD) combustion which applied high temperature flue gas recirculation has been confirmed for its effectiveness with regard to solid fuel as well. MILD combustion is affected by the flue gas recirculation ratio and the composition of recirculation gas, so its NOx reduction efficiency is determined by them. In order to investigate the influence of factors which determine the reduction efficiency of NOx in MILD coal combustion, this study changed the flow rate and concentration of nitrogen (N2), carbon dioxide (CO2) and steam (H2O) which simulate the recirculation gas during the MILD coal combustion using our lab-scale drop tube furnace and performed the combustion experiment. As a result, its influence by the composition of recirculation gas was insignificant and it was shown that flue gas recirculation ratio influences the change of NOx concentration greatly. Implications: We investigated the influence of factors determining the nitrogen oxides (NOx) reduction efficiency in MILD coal combustion, which applied high-temperature flue gas recirculation. Using a lab-scale drop tube furnace and simulated recirculation gas, we conducted combustion testing changing the recirculation gas conditions. We found that the flue gas recirculation ratio influences the reduction of NOx emissions the most.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号