首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   0篇
  国内免费   2篇
废物处理   19篇
环保管理   1篇
综合类   5篇
基础理论   4篇
污染及防治   7篇
评价与监测   1篇
社会与环境   4篇
  2023年   1篇
  2022年   1篇
  2021年   2篇
  2019年   1篇
  2017年   2篇
  2014年   2篇
  2013年   1篇
  2012年   1篇
  2011年   2篇
  2010年   5篇
  2009年   4篇
  2007年   1篇
  2006年   3篇
  2005年   3篇
  2004年   3篇
  2003年   2篇
  2002年   1篇
  2001年   2篇
  1999年   1篇
  1995年   1篇
  1982年   1篇
  1969年   1篇
排序方式: 共有41条查询结果,搜索用时 15 毫秒
21.
Several attempts have been made to detect and retrieve fetal nucleated cells including nucleated erythrocytes (NRBCs), leukocytes, and trophoblasts in maternal blood. We have recently developed a new method for non-invasive fetal DNA diagnosis from maternal blood. Peripheral blood granulocytes including NRBCs were isolated by a discontinuous density gradient method using Percoll (Pharmasia). NRBCs were found and retrieved at a single cell level using a micromanipulator under a microscope. To determine whether the origin of the NRBCs was maternal or fetal, the NRBCs were analysed by polymerase chain reaction (PCR) amplification to determine the presence of a Y-chromosome-specific repeat sequence in mothers carrying male fetuses. We were successful in predicting fetal sex accurately in 10 out of 11 samples taken from maternal blood. This new technique opens up fetal DNA diagnosis from maternal blood during the first trimester of pregnancy to the whole population because there is no risk to the fetus or the mother.  相似文献   
22.
Total diet study (TDS) samples of 14 food groups from 16 locations in Japan, collected in 1999 and 2000, were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) to estimate the update of daily intake of these contaminants from food. The mean daily intake of toxic equivalency (TEQ) for an adult weighing 50 kg, calculated at non-detected isomer concentrations equal to zero (ND=0), was estimated to be 2.25 pg TEQ/kg b.w./day. When non-detected isomer concentrations are assumed to be equal to half of the limits of detection (ND=1/2 LOD), the mean daily intake was estimated to be 3.22 pg TEQ/kg b.w./day. These values were below the tolerable daily intake (TDI) of 4 pg TEQ/kg b.w. for PCDD/Fs and dioxin-like PCBs set in Japan. In both the estimates, the mean daily intakes were highest from fish and shellfish (76.9% at ND=0 and 53.9% at ND=1/2 LOD of the total TEQs), followed by those from meat and eggs (15.5% at ND=0 and 11.7% at ND=1/2 LOD of the total TEQs). Congener specific data revealed that these total TEQ levels were dominated by 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF and 3,3,4,4,5-PeCB in each case (71.7% at ND=0 and 63.1% at ND=1/2 LOD of the total TEQs). The dioxin-like PCBs (non-ortho and mono-ortho PCBs) accounted for about 50% of these total TEQs. These data will be very useful in the risk assessment of PCDD/Fs and dioxin-like PCBs from food in Japan.  相似文献   
23.
Although international negotiation on the mitigation of climate change is a process of determining burden-sharing rules between countries, there has been no clear agreement on equity principles for burden sharing. During the negotiating process up to the Kyoto Protocol, various proposals were made on such burden-sharing rules, but an agreement on emission targets for Annex I countries was achieved without explicitly agreeing to any rules. In the next phase of the negotiation, debates on emission targets are likely to shift from those between developed countries to those between all parties to the convention. In such a phase, debates on burden-sharing rules will be revisited. The purpose of this paper is: (1) to determine implicitly a formula for the rule for burden sharing between Annex I countries that was considered to be underlying the emission targets of the Kyoto Protocol, and (2) to examine plausible emission targets and timing of commitments for non-Annex I countries in the future by using the result of the analysis on the Kyoto Protocol. A multi-regression method is used for this purpose. It was concluded that the burden sharing between Annex I countries in the Kyoto Protocol can mostly be explained by three variables: the increase in the rate of CO2 emission during the years 1990 to 2010, the increase in the rate of afforestation between 1990 and 1995, and the GDP per capita at the time of negotiation. The timing of future commitments of developing countries and the levels of targets differ widely, depending on which index or formula is agreed as "equitable". Some of the developing countries would have to start limiting their emissions within several years if GDP per capita or CO2 per capita were chosen as the burden-sharing indicator. Developing countries would not have to make commitments until the mid-late 21st century if population growth rate were chosen. If the inferred formula of the Kyoto Protocol were applied to developing countries, they would have had to start mild limitation from 1990.  相似文献   
24.
日本是亚洲太平洋地区进行法人报告的首创者.本文回顾了过去的十年中日本环境报告举措的发展.也描述了对日本公司进行的环境报告的调查反应.在日本正在开始注重确保环境报告可靠性的方法.环境上先进公司的环境报告正在朝可持续发展性报告的方向转移.  相似文献   
25.
Goal, Scope and Background Cadavers for gross anatomy laboratories are usually prepared by using embalming fluid which contains formaldehyde (FA) as a principal component. During the process of dissection, FA vapors are emitted from the cadavers, resulting in the exposure of medical students and their instructors to elevated levels of FA in the laboratory. The American Conference of Governmental Industrial Hygienists (ACGIH) has set a ceiling limit for FA at 0.3 ppm. In Japan, the Ministry of Health, Labour and Welfare has set an air quality guideline defining two limit values for environmental exposure to FA: 0.08 ppm as an average for general workplaces and 0.25 ppm for specific workplaces such as an FA factory. Although there are many reports on indoor FA concentrations in gross anatomy laboratories, only a few reports have described personal FA exposure levels. The purpose of the present study was to clarify personal exposure levels as well as indoor FA concentrations in our laboratory in order to investigate the relationship between them. Methods The gross anatomy laboratory was evaluated in the 4th, 10th and 18th sessions of 20 laboratory sessions in total over a period of 10 weeks. Air samples were collected using a diffusive sampling device for organic carbonyl compounds. Area samples were taken in the center and four corners of the laboratory during the entire time of each session (4-6 hours). Personal samples were collected from instructors and students using a sampling device pinned on each person's lapel, and they were 1.1 to 6 hours in duration. Analysis was carried out using high performance liquid chromatography. Results and Discussion Room averages of FA concentrations were 0.45, 0.38 and 0.68 ppm for the 4th, 10th and 18th sessions, respectively, ranging from 0.23 to 1.03 ppm. These levels were comparable to or relatively lower than the levels reported previously, but were still higher than the guideline limit for specific workplaces in Japan and the ACGIH ceiling limit. The indoor FA concentrations varied depending on the contents of laboratory sessions and seemed to increase when body cavity or deep structures were being dissected. In all sessions but the 4th, FA levels at the center of the room were higher than those in the corners. This might be related to the arrangement of air supply diffusers and return grills. However, it cannot be ruled out that FA levels in the corners were lowered by leakage of FA through the doors and windows. Average personal exposure levels were 0.80, 0.45 and 0.51 ppm for instructors and 1.02, 1.08 and 0.89 ppm for students for the 4th, 10th and 18th session, respectively. The exposure levels of students were significantly higher than the mean indoor FA concentrations in the 4th and 10th sessions, and the same tendency was also observed in the 18th session. The personal exposure level of instructors was also significantly higher than the indoor FA level in the 4th session, while they were almost the same in the 10th and 18th sessions. Differences in behavior during the sessions might reflect the differential personal exposure levels between students and instructors. Conclusion The present study revealed that, if a person is close to the cadavers during the gross anatomy laboratory, his/her personal exposure level is possibly 2 to 3-fold higher than the mean indoor FA concentration. This should be considered in the risk assessment of FA in gross anatomy laboratories. Recommendation and Outlook If the risk of FA in gross anatomy laboratories is assessed based on the indoor FA levels, the possibility that personal exposure levels are 2 to 3-fold higher than the mean indoor FA level should be taken into account. Otherwise, the risk should be assessed based on the personal exposure levels. However, it is hard to measure everyone's exposure level. Therefore, further studies are necessary to develop a method of personal exposure assessment from the indoor FA concentration.  相似文献   
26.
Alkaline eluate from municipal solid waste (MSW) incineration residue deposited in landfill alkalizes waste and soil layers. From the viewpoint of accelerating stability and preventing heavy metal elution, pH of the landfill layer (waste and daily cover soil) should be controlled. On the other hand, pH of leachate from existing MSW landfill sites is usually approximately neutral. One of the reasons is that daily cover soil can neutralize alkaline solution containing Ca2+ as cation. However, in landfill layer where various types of wastes and reactions should be taken into consideration, the ability to neutralize alkaline solutions other than Ca(OH)2 by soil should be evaluated. In this study, the neutralization capacities of various types of soils were measured using Ca(OH)2 and NaOH solutions. Each soil used in this study showed approximately the same capacity to neutralize both alkaline solutions of Ca(OH)2 and NaOH. The cation exchange capacity was less than 30% of the maximum alkali neutralization capacity obtained by the titration test. The mechanism of neutralization by the pH-dependent charge can explain the same neutralization capacities of the soils. Although further investigation on the neutralization capacity of the soils for alkaline substances other than NaOH is required, daily cover soil could serve as a buffer zone for alkaline leachates containing Ca(OH)2 or other alkaline substances.  相似文献   
27.
The mass and element balance in municipal solid waste composting facilities that handle food waste was studied. Material samples from the facilities were analyzed for moisture, ash, carbon, nitrogen, and the oxygen consumption of compost and bulking material was determined.Three different processes were used in the food waste composting facilities: standard in-vessel composting, drying, and stand-alone composting machine. Satisfactory results were obtained for the input/output ash balance despite several assumptions made concerning the quantities involved. The carbon/nitrogen ratio and oxygen consumption values for compost derived only from food waste were estimated by excluding the contribution of the bulking material remaining in the compost product. These estimates seemed to be suitable indices for the biological stability of compost because there was a good correlation between them, and because the values seemed logical given the operating conditions at the facilities.  相似文献   
28.
A statistical study on the behavior of ground-level O3 concentration in different regions of a large urban area was carried out, with emphasis on pollutant gas concentrations and meteorological variables. The study was based on data generated by a network of measuring stations distributed throughout the S?o Paulo Metropolitan Area, in regions with different characteristics of traffic and economic activities. The combined application of principal component analysis and clustering techniques to data collected from 1997 until 2000 has led to the identification of implicit relationships between variables that have been associated with dominant processes related to O3 formation in different locations. Similarities between different regions of the city have also been detected and associated with local characteristics. The results indicate that the application of such statistical techniques to data collected in large urban areas enables the grouping of different regions according to their behavior in terms of O3 levels, as well as the identification of dominant processes in each group. These techniques are thus important in the planning of air pollution policies, especially in the case of O3, a pollutant that is not directly related to pollution levels alone.  相似文献   
29.
We report here the latest levels of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/Fs) and coplanar polychlorinated biphenyls (Co-PCBs) in leafy vegetables in Japan as well as the effect of cooking processes on the reduction of these contaminants. Three kinds of leafy vegetables (“komatsuna”, lettuce and spinach) from seven districts in Japan in 1998 were analyzed for the 2,3,7,8-chlorine substituted PCDD/Fs and three non-ortho-PCBs (#77, 126 and 169). The mean total TEQ levels (using the WHO-TEFs) in the komatsuna, lettuce and spinach were 0.094, 0.025 and 0.196 pg/g fresh weight, respectively. The TEQ levels are dominated by 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF and 3,3,4,4,5-PeCB in many of the samples. For one of these isomers, the 2,3,4,7,8-PeCDF TEQ levels showed good correlation with the total TEQ levels in the samples (r=0.957). This suggests that 2,3,4,7,8-PeCDF may be an indicator for dioxin contamination in the analysis of the leafy vegetables. Also, the effects of two cooking processes (washing and washing followed by boiling) on the dioxin levels in two types of spinach samples were investigated. On average, in both samples, the total concentrations of the PCDDs, PCDFs and Co-PCB were reduced to about 38%, 73% and 88% of the initial concentrations by washing, and to 21%, 35% and 61% of the initial concentrations by washing followed by boiling. The total TEQ levels were reduced to about 30% of the initial TEQ levels by washing followed by boiling. Significant reductions in the TEQ levels were observed in the cooked samples. Thus, the cooking processes may reduce the risk of dioxin intake from the leafy vegetables.  相似文献   
30.
This article focuses on the historical development of landfill technology since the beginning of the nineteenth century in Japan. The regulations and guidelines that form a framework for the technology are reviewed, and the historical background and the current state of Japanese municipal solid waste (MSW) management are described. Through the analysis of data collected from facility leaflets, changes in the leachate treatment system are surveyed. Finally, the concept of the “sustainable bioreactor landfill with low organics” is proposed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号