This paper provides an overview and the main results of a study aiming to evaluate current and alternative inspection and maintenance (I/M) programs to control emissions from in-use cars in Europe. For this purpose, a large number of passenger cars from five countries (France, Germany, Greece, the Netherlands, and the United Kingdom) were tested according to a common test protocol that included a variety of driving cycles and short tests, both legislative and specifically developed for this exercise. Evaluation of all test results was conducted with the objective of defining effective I/M test procedures and examining the potential of periodic I/M programs to reduce pollutant emissions and improve fuel economy of in-use cars. The results indicate that the current idle test used for catalyst-equipped cars in Europe is probably ineffective, while short transient loaded testing was found to offer higher potential in environmental terms. Regarding conventional gasoline cars, it is concluded that the idle test is sufficient, provided that the CO cut point is reduced and an HC test is added at high idle. Finally, the effectiveness of the free acceleration smoke test for diesels is questioned, while a transient cycle with continuous opacity measurement was found to be very promising. A companion paper further uses these results to analyze the likely cost-effectiveness on a per-country basis and discusses the possible effect of maintenance on emissions. 相似文献
Regional Environmental Change - The risks, pressures and threats on Small Island Developing States (SIDS) of the Pacific from climate change are often perceived by outsiders as overwhelming, both... 相似文献
Maps of pollutants concentration are usually generated by means of interpolation and extrapolation methods. The quality of the results depends mainly of the number of permanent or temporary measuring stations. This paper deals with a method for the virtual densification of the network of stations. The method creates "virtual measuring stations". It aims at improving the quality of interpolation by increasing the number of data on pollutant concentration. The virtual stations are determined by the means of a classification method applied to each pixel of the area under concern. Discriminating elements are pollutants emission classes, land cover types, urban morphological indicators created to this purpose and distance to major roads. A first implementation was made for particulate matter (PM) for the city of Strasbourg (France) using thin-plates spline interpolation method in Arcview 9 GIS. The relative Root Mean Square Error decreases from 49% for five input stations down to 15% for the virtual stations. 相似文献
In the de-novo synthesis and formation of PCDD/PCDF, the transfer of inorganic chlorine to the carbonaceous material of fly ash plays an important role. Here, copper acts as a catalyst in the chlorination reaction. In experiments in the range of 250-350 degrees C under helium, we determined the stoichiometry of the chlorination reaction with model systems. Therefore, it was necessary to develop a method to quantify the copper(II) and copper(I) ions. In a combination of solid electron paramagnetic (spin) resonance spectroscopy (EPR) for Cu(I), and X-ray fluorescence spectroscopy (XRFA) analysis for Cu (total), we found a way for the quantification of copper(I) and (II). With these experiments, we can show that the chlorination reaction is relatively fast and comes to a stop under helium, after the copper(II) is reduced. The ratio between the organic chlorine formed and copper(II) reduced is, at the end of the reaction, 0.5, which is in agreement with the following reaction: 2CuCl2 + R-H-->2CuCl + R-Cl + HCl. 相似文献
The formation rates of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from polycyclic aromatic hydrocarbons (PAHs), activated carbon, and phenol were compared. The heat treatment at 300°C of all tested PAH on silica in the presence of CUCl2 Preferred PCDDs over PCDDs. Perylene reproducibly gave a higher yield of PCDDs than activated carbon gave under the same conditions. The formation rate of PCDDs from perylene could be higher than the values in this study because the residence time of perylene in the reactor is shorter than that of activated carbon. PCDDs were mainly formed from phenol. 相似文献
OCDD and OCDF spiked silica/graphite based model fly ash containing various copper compounds and metal oxides were thermally treated under oxygen deficient conditions. All copper compounds tested showed a considerable dechlorination/hydrogenation reaction at 260 °C. After 30 min at 340 °C, less than 1% of the spiked OCDD and OCDF was recovered as T4CDD/F to OCDD/F. Other compounds tested demonstrated a lower rate of dechlorination compared to the copper compounds. However, all other metal oxides showed a small dechlorination effect at 260 °C, which was considerably increased at 340 °C.
The model fly ash containing the different copper compounds or metal oxides showed comparable PCDD and PCDF isomer patterns after thermal treatment. However, small differences were observed among the different tested compounds. The PCDD and PCDF isomer patterns on the model fly ashes were similar to patterns found during dechlorination experiments on fly ashes from waste incineration processes.
Model fly ash containing Ca(OH)2 exhibited the highest destruction potential, but a low dechlorination potential. In contrast, model fly ash containing any of the remaining compounds tested, was found to predominantly dechlorinate the spiked OCDD and OCDF. 相似文献