全文获取类型
收费全文 | 168篇 |
免费 | 1篇 |
国内免费 | 8篇 |
专业分类
安全科学 | 12篇 |
废物处理 | 22篇 |
环保管理 | 8篇 |
综合类 | 18篇 |
基础理论 | 23篇 |
污染及防治 | 72篇 |
评价与监测 | 20篇 |
社会与环境 | 2篇 |
出版年
2022年 | 5篇 |
2021年 | 6篇 |
2019年 | 5篇 |
2018年 | 7篇 |
2017年 | 10篇 |
2016年 | 6篇 |
2015年 | 2篇 |
2014年 | 10篇 |
2013年 | 18篇 |
2012年 | 14篇 |
2011年 | 16篇 |
2010年 | 10篇 |
2009年 | 10篇 |
2008年 | 9篇 |
2007年 | 10篇 |
2006年 | 6篇 |
2005年 | 3篇 |
2004年 | 7篇 |
2003年 | 5篇 |
2002年 | 6篇 |
2001年 | 7篇 |
1999年 | 1篇 |
1998年 | 1篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1991年 | 1篇 |
排序方式: 共有177条查询结果,搜索用时 0 毫秒
31.
I-Risk: development of an integrated technical and management risk methodology for chemical installations 总被引:1,自引:0,他引:1
I. A. Papazoglou L. J. Bellamy A. R. Hale O. N. Aneziris B. J. M. Ale J. G. Post J. I. H. Oh 《Journal of Loss Prevention in the Process Industries》2003,16(6):575-591
This paper presents an integrated quantitative risk assessment method for hazardous installations, taking into account management as well as technical design and producing risk level measures. The key components of the I-Risk methodology are the technical model, the management model and their interface. The technical model consists of developing a master logic diagram (MLD) delineating the major immediate causes of loss of containment (LOC) and associated quantitative models for assessing their frequency. The management model consists of the tasks, which must be carried out systematically in the primary business functions (such as operations, emergency operations, maintenance and modifications). A management audit quantifies the quality of these management tasks. The management–technical interface modifies certain parameters of the technical model on the basis of the quality of the safety management system of the specific installation. The methodology is exemplified through its application to the risk assessment of an ammonia storage facility. A detailed technical model simulating the response of the system to various initiating events is developed along with a detailed management model simulating the influence of the plant-specific management and organisational practices. The overall effect is quantified through the frequency of release of ammonia as a result of a loss of containment in a storage tank and in a pipeline. 相似文献
32.
Sung-woon Lee Soon-young Oh Tae-gu Kim 《Journal of Loss Prevention in the Process Industries》2013,26(5):904-907
Many chemicals are being developed with the growth of science technology. Such chemicals bring many advantages to humans but also cause many social problems because of the hazards of the materials. Therefore, it is necessary to have a system which identifies the hazards of chemicals. Some acts or regulations about information on warning labels or MSDS (Material Safety Data Sheet) information for chemicals are similar in each country but there are differences in definitions of degree of hazard, standard classification of harmful level, and indication methods. GHS is the indication method of worldwide integrated classification standard in order to prevent damage caused by disease or risks of accidents resulting from confusion by the users. In keeping pace with the world trend, Korea has conducted translation of the GHS manual from UN and selected it as the official GHS manual of the Korean government. The official Korean GHS translated version was published in July 2005. After that, the Korea Ministry of Employment and Korea Labor and the Ministry of Environment have implemented GHS MSDS for chemical substances since July 1, 2010 so that manufacturers and importers are required to apply it. The full implementation for compound materials will start on July 1, 2013. In Korea, database information for chemicals is provided by four organizations including The Korea Occupational Safety and Health Agency. However, domestic information on chemicals provided by domestic information providers has problems including differences in basic content and incorrect recording because of trade secrets. Efforts for improvement including reinforcing training for manufacturers and importers on recording consistent information for different organizations are urgently needed. 相似文献
33.
Yeo-Myeong Yun Hang-Sik Shin Chang-Kyu Lee You-Kwan Oh Hyun-Woo Kim 《Environmental science and pollution research international》2016,23(8):7138-7145
Converting lipid-extracted microalgal wastes to methane (CH4) via anaerobic digestion (AD) has the potential to make microalgae-based biodiesel platform more sustainable. However, it is apparent that remaining n-hexane (C6H14) from lipid extraction could inhibit metabolic pathway of methanogens. To test an inhibitory influence of residual n-hexane, this study conducted a series of batch AD by mixing lipid-extracted Chlorella vulgaris with a wide range of n-hexane concentration (~10 g chemical oxygen demand (COD)/L). Experimental results show that the inhibition of n-hexane on CH4 yield was negligible up to 2 g COD/L and inhibition to methanogenesis became significant when it was higher than 4 g COD/L based on quantitative mass balance. Inhibition threshold was about 4 g COD/L of n-hexane. Analytical result of microbial community profile revealed that dominance of alkane-degrading sulfate-reducing bacteria (SRB) and syntrophic bacteria increased, while that of methanogens sharply dropped as n-hexane concentration increased. These findings offer a useful guideline of threshold n-hexane concentration and microbial community shift for the AD of lipid-extracted microalgal wastes. 相似文献
34.
Jung Hwan Oh Eui-Jong Lee Jeong Ik Oh Jong-Oh Kim Am Jang 《Environmental science and pollution research international》2016,23(8):7074-7080
As cities are becoming increasingly aware of problems related to conventional mobile collection systems, automated pipeline-based vacuum collection (AVAC) systems have been introduced in some densely populated urban areas. The reasons are that in addition to cost savings, AVAC systems can be efficient, hygienic, and environmentally friendly. Despite difficulties in making direct comparisons of municipal waste between a conventional mobile collection system and an AVAC system, it is meaningful to measure the quantities in each of these collection methods either in total or on a per capita generation of waste (PCGW, g/(day*capita)) basis. Thus, the aim of this study was to assess the difference in per capita generation of household waste according to the different waste collection methods in Korea. Observations on household waste show that there were considerable differences according to waste collection methods. The value of per capita generation of food waste (PCGF) indicates that a person in a city using AVAC produces 60 % of PCGF (109.58 g/(day*capita)), on average, compared with that of a truck system (173.10 g/(day*capita)) as well as 23 %p less moisture component than that with trucks. The value of per capita generation of general waste (PCGG) in a city with an AVAC system showed 147.73 g/(day*capita), which is 20 % less than that with trucks delivered (185 g/(day*capita)). However, general waste sampled from AVAC showed a 35 %p increased moisture content versus truck delivery. 相似文献
35.
TaeSeok Oh MinJeong Kim JungJin Lim OnYu Kang K. Vidya Shetty B. SankaraRao 《Journal of the Air & Waste Management Association (1995)》2013,63(5):517-526
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover, the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.
Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. 相似文献
36.
Park JS Oh S Shin MY Kim MK Yi SM Zoh KD 《Environmental pollution (Barking, Essex : 1987)》2008,154(1):12-20
Dissolved gaseous mercury (DGM) and total mercury (TM) concentrations were measured in Juam Reservoir, Korea. DGM concentrations were higher in spring (64+/-13pgL(-1)) and summer (109+/-15pgL(-1)), and lower in fall (20+/-2pgL(-1)) and winter (23+/-6pgL(-1)). In contrast, TM concentrations were higher in fall (3.2+/-0.1ngL(-1)) and winter (3.3+/-0.1ngL(-1)) than in spring (2.3+/-0.1ngL(-1)) and summer (2.2+/-0.4ngL(-1)). DGM concentrations were correlated with water temperature (p<0.0001), ORP (p<0.0001), UV intensity (UV-A: p=0.008; UV-B: p=0.003), and DOC concentration (p=0.0107). DGM concentrations varied diurnally with UV intensity. The average summer DGM (109+/-15pgL(-1)) and TM (2.2+/-0.4ngL(-1)) concentrations in Juam Reservoir were higher than the averages for North American lakes (DGM=38+/-16pgL(-1); TM=1.0+/-1.2ngL(-1)), but lower than levels reported for Baihua Reservoir in China. 相似文献
37.
Seasonal and particle size-dependent variations in gas/particle partitioning of PCDD/Fs 总被引:1,自引:0,他引:1
Lee SJ Ale D Chang YS Oh JE Shin SK 《Environmental pollution (Barking, Essex : 1987)》2008,153(1):215-222
This study monitored particle size-dependent variations in atmospheric polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Two gas/particle partitioning models, the subcooled liquid vapor pressure (P(L)(0)) and the octanol-air partition coefficient (K(OA)) model, were applied to each particle sizes. The regression coefficients of each fraction against the gas/particle partition coefficient (K(P)) were similar for separated particles within the same sample set but differed for particles collected during different periods. Gas/particle partitioning calculated from the integral of fractions was similar to that of size-segregated particles and previously measured bulk values. Despite the different behaviors and production mechanisms of atmospheric particles of different sizes, PCDD/F partitioning of each size range was controlled by meteorological conditions such as atmospheric temperature, O(3) and UV, which reflects no source related with certain particle size ranges but mixed urban sources within this city. Our observations emphasize that when assessing environmental and health effects, the movement of PCDD/Fs in air should be considered in conjunction with particle size in addition to the bulk aerosol. 相似文献
38.
Effect of amorphous silica and silica sand on removal of chromium(VI) by zero-valent iron 总被引:1,自引:0,他引:1
The effect of two surfaces (amorphous silica and silica sand) on the reduction of chromium(VI) by zero-valent iron (Fe(0)) was investigated using batch reactors. The amendment of both surfaces significantly increased the rate and extent of Cr(VI) removal. The rate enhancement by amended surfaces is presumed to result from scavenging of Fe(0)-Cr(VI) reaction products by the provided surfaces, which minimized surface deactivation of Fe(0). The rate enhancing effect was greater for silica compared to sand, and the difference is attributed to silica's higher surface area, greater affinity for reaction products and pH buffering effect. For a given mass of Fe(0), the reactivity and longevity of Fe(0) to treat Cr(VI) increased with increasing dose of silica. Elemental analyses of the reacted iron and silica revealed that chromium removed from the solution was associated with both surfaces, with its mass distribution being approximately 1:1 per mass of iron and silica. The overall result suggests reductive precipitation was a predominant Cr(VI) removal pathway, which involves initial reduction of Cr(VI) to Cr(III), followed by formation of Cr(III)/Fe(III) hydroxides precipitates. 相似文献
39.
Marine protected areas increasingly are challenged to maintain or increase tourism benefits while adequately protecting resources. Although carrying capacity strategies can be used to cope with use-related impacts, there is little understanding of divers themselves, their management preferences, and how preferences relate to conservation goals. By using a stated preference choice modeling approach, we investigated the choices divers make in selecting diving trips to marine protected areas as defined by use level, access, level of supervision, fees, conservation education, and diving expectations. Logit models showed that divers preferred a more restrictive management scenario over the status quo. Divers favored reductions in the level of site use and increased levels of conservation education. Divers did not favor fees to access protected areas, having less access to the resource, or extensive supervision. Finally, divers were much more willing to accept increasingly restrictive management scenarios when they could expect to see increased marine life. 相似文献
40.
Hwang MK Kim YK Oh IB Lee HW Kim CH 《Journal of the Air & Waste Management Association (1995)》2007,57(12):1480-1488
To aid the studies of long-term impact assessment of cumulative ozone (O3) exposures, the representative 8-hr O3 pollution patterns have been identified over the Greater Seoul Area (GSA) in Korea. Principal component analysis and two-stage clustering techniques were used to identify the representative O3 patterns, and numerical and observational analyses were also used to interpret the identified horizontal distribution patterns. The results yielded three major O3 distribution patterns, and each of the three patterns was found to have strong correlations with local and synoptic meteorological conditions over the GSA. For example, pattern 1, accounting for 46% of O3 concentration distributions, mostly occurred under relatively weak westerly synoptic winds. The predominant features of this pattern were infrequent high O3 levels but a distinct gradient of O3 concentration from the western coastal area to the eastern inland area that was mainly induced by the local sea breeze. Pattern 2, accounting for 31% of O3 concentration distributions, was found with higher O3 levels in the western coastal area but lower in the eastern inland area. This is due to the modified sea breeze under the relatively stronger easterly opposing synoptic wind, affecting the high O3 occurrence in the western coastal area only. However, pattern 3, accounting for 21% of O3 concentration distributions, showed significantly higher O3 concentrations over the whole GSA mainly due to the retarded and slow-moving sea-breeze front under the weak opposing synoptic flow. Modeling study also indicated that local and synoptic meteorological processes play a major role in determining the high O3 concentration distribution patterns over the GSA. 相似文献