首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   144篇
  免费   2篇
  国内免费   5篇
安全科学   4篇
废物处理   23篇
环保管理   17篇
综合类   8篇
基础理论   26篇
污染及防治   61篇
评价与监测   10篇
社会与环境   2篇
  2022年   3篇
  2021年   1篇
  2020年   1篇
  2019年   2篇
  2018年   4篇
  2017年   6篇
  2016年   6篇
  2015年   2篇
  2014年   6篇
  2013年   9篇
  2012年   6篇
  2011年   15篇
  2010年   13篇
  2009年   8篇
  2008年   12篇
  2007年   15篇
  2006年   8篇
  2005年   2篇
  2004年   11篇
  2003年   6篇
  2002年   4篇
  2001年   3篇
  2000年   2篇
  1998年   1篇
  1997年   1篇
  1992年   1篇
  1989年   2篇
  1984年   1篇
排序方式: 共有151条查询结果,搜索用时 15 毫秒
41.
This study assessed bacterial concentrations in indoor air at 25 underground railway stations in Seoul, Korea, and investigated various related factors including the presence of platform screen doors (PSD), depth of the station, year of construction, temperature, relative humidity, and number of passengers. A total of 72 aerosol samples were collected from all the stations. Concentrations of total airborne bacteria (TAB) ranged from not detected (ND) to 4997 CFU m?3, with an overall geometric mean (GM) of 191 CFU m?3. Airborne bacteria were detected at 23 stations (92%) and Gram-negative bacteria (GNB) were detected at two stations (8%). TAB concentrations of four stations (16%) exceeded 800 CFU m?3, the Korea indoor bio-aerosol guideline. The results of the study showed that TAB concentrations at the stations without PSD showed higher TAB concentrations than those with PSD, though not at statistically significant levels. TAB concentrations of deeper stations revealed significantly higher levels than those of shallower stations. Based on this study, it is recommended that mitigation measures be applied to improve the indoor air quality (IAQ) of underground railway stations in Seoul, with focused attention on deeper stations.  相似文献   
42.
Journal of Material Cycles and Waste Management - The ilmenite-chloride process has used for the production of TiCl4 from the ilmenite (FeTiO3) ore, which produces cyclone dust containing mostly...  相似文献   
43.
Lee C  Lee Y  Yoon J 《Chemosphere》2006,65(7):1163-1170
This study systematically investigates the characteristic degradation behaviors of dimethylsulfoxide (DMSO) by the streamer corona discharge process (SCDP) in water. The analysis of the oxidized intermediates of DMSO shows that hydroxyl radical (*OH) is the main oxidant responsible for the degradation of DMSO in the SCDP. The various experiments on the degradation and mineralization of DMSO, and the effect of the *OH scavenger suggest that the SCDP produces locally concentrated *OHs in and around the plasma channel. This explanation was also supported by the formation of H(2)O(2) and the effect of the *OH scavenger on the H(2)O(2) production rate in the SCDP. Based on the kinetic data for the degradation of DMSO and the production of H(2)O(2) in the SCDP, the volume of the active region in which the *OHs are concentrated, and the effective concentration of *OH in that region were estimated to be 0.21 microl and 5.0 x 10(-3)M, respectively. This level of *OH concentration in the SCDP is approximately 10(7)-10(9) times higher than that generated in ordinary advanced oxidation processes using *OH. The ramifications of the results obtained in this study on successful water treatment using the SCDP are also discussed.  相似文献   
44.
Kim KS  Hong KH  Ko YH  Yoon KD  Kim MG 《Chemosphere》2003,53(6):601-607
Emission characteristics of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in diesel engine were studied with variable load rate of the diesel engine with the emission test cycles, US D-13 mode. The load rate is changed from 25% to 50% and 75% at constant speed of 2400 rpm. PCDD/Fs concentration and phase distribution of PCDD/Fs with the isokinetic sampling of exhaust gas is obtained in this study. The average PCDD/Fs concentrations per unit of exhaust gas with 25%, 50% and 75% load rate are 14.5, 6.9 and 6.4 pg-TEQ/N m3, respectively. In all diesel engine runs, PCDFs are more prevalent than PCDDs. As a load rate is increased, the ratio of PCDDs is gradually decreased. The amount of high-chlorinated PCDDs emitted in diesel engine is larger than that of low-chlorinated PCDDs. The significant emission form of PCDD/Fs produced from diesel engines exhaust is a gas phase.  相似文献   
45.
ABSTRACT: Proper selection of curve number values will improve the capability of the SCS-Curve Number procedure in predicting runoff. Both CREAMS and GLEAMS models use the Smith and Williams (1980) approach of converting CNII (curve number value for average antecedent moisture conditions) into CNI (curve number value for dry antecedent moisture conditions) in calculating the soil retention parameter (S). CREAMS and GLEAMS have been found to under predict runoff because of the internal conversion of CNII to CNI. This study shows modifications of the GLEAMS model using CMI without converting it to CM and it also shows the seasonal curve number approaches with and without converting CNII to CNI. Results indicate that using CNII without internal conversion to CNI provides better runoff and erosion predictions than the original version of GLEAMS and versions with seasonal curve numbers when tested with four years of field data in the Coastal Plain physiographic region of Maryland.  相似文献   
46.
An understanding of the long-term changes in the nitrate contamination pattern of unconfined groundwater is critical to conservation of drinking water in rural areas supporting mixed land-use activities such as cropping, livestock farming, and residence. To examine the effect of different land-use activities on nitrate contamination, groundwater samples were collected monthly for 3 years (1997–1999) from 12 wells in rural areas with different land-use activities and analyzed for the concentrations and N isotopic ratios (δ15N) of nitrate. The characteristics of nitrate contamination clearly differed with land-use activities. The percentages of samples that had a nitrate concentration exceeding the national standard for drinking water (10 mg N L−1) were 0, 23, 43, and 67% for the uncontaminated natural area, cropping area, cropping-livestock farming complex area, and residential area, respectively. The range of δ15N values was between +1.4 and +4.5‰ for groundwater nitrate from the uncontaminated natural area. In the cropping area, the δ15N values were slightly different with the type of fertilizer applied to fields in the vicinity of the well, and the values ranged between +8.7 and +14.4‰ for the compost-applied area and between +4.5 and +8.5‰ for the area where urea was applied with compost. The δ15N values of the cropping-livestock farming complex area ranged from +1.0 to +17.7‰, probably resulting from mixed contamination sources (inorganic fertilizer and livestock manure). The well located closest to the livestock feedlot had relatively higher δ15N values, with a range between +8.7 and +17.6‰. In the residential area, a higher δ15N (most frequently above +10‰) of nitrate suggested that the major source of contamination was effluent from leaky septic tanks. Our data showed that unconfined groundwater is susceptible to land-use activities above the aquifers, and the impacts of the activities could be more precisely inferred from long-term data on the concentration and δ15N of nitrate. By determining the impacts, more effective (specific to contamination sources) measures for preventing groundwater quality could be implemented.  相似文献   
47.
48.
Airborne in-situ measurements were analyzed to investigate the effects of biomass burning and regional background aerosols on cloud condensation nuclei (CCN) activity in the Pacific Dust Experiment (PACDEX) during April and May 2007. Airmass trajectories with both horizontal and vertical motions were provided to identify the aerosol sources. In the biomass burning cases, the elevated aerosol layers were clearly observed at dry conditions because of the convection of airmass in the source region. The relative aging of aerosols was supported by the ratios of BC to particles with size ranging from 0.1 to 1.0 μm (N0.1–1.0) and BC to carbon monoxide. Compared to aerosols in the precedent plume of biomass burning, aged particles in the latter plume were more activated to CCN at 0.4% (CCN0.4%) than 0.1% supersaturation (CCN0.1%) due to aerosols chemical modification during the aging process. On the other hand, significant difference of CCN0.4% and CCN0.1% at regional background aerosols over the Pacific Ocean was due to the activated particles below 1 μm in diameter. Although higher concentrations of aged particles were observed over the eastern Pacific Ocean, activated aerosols to cloud droplet was comparatively similar in the western Pacific Ocean because of the similar concentrations of N0.1–1.0 in both cases.  相似文献   
49.
The characteristics of bubble properties and the chaotic flow behavior of gas were investigated in an annular fluidized bed (0.102 m in inner diameter and 2 m in height) because the behavior of gas flow in such a reactor is one of the important factors governing reactor operation, reactor performance, and the reaction itself. Pressure fluctuations as a state variable for the analysis of gas flow behavior were measured and analyzed. Bubble properties were determined by adopting the cross-correlation function of pressure fluctuations. The resultant chaotic flow behavior of gas was interpreted by means of chaotic parameters such as the Kolmogorov entropy. It was found that the Kolmogorov entropy could be utilized effectively to explain the nonlinear dynamic behavior of gas-solid flow in the annular fluidized bed. The pierced length and rising velocity of bubbles increased with increasing gas velocity, bed temperature, and particle size of the bed material. The bubble frequency increased with increasing gas velocity and bed temperature, while it decreased with increasing particle size of the bed material. Correlations to predict the bubble properties in annular fluidized-bed reactors were suggested.  相似文献   
50.
The aim of this research is to find the optimum smoke extraction rate through the ventilation shaft in case of a fire in a long road tunnel. Furthermore, it is also investigated whether the current emergency ventilation design practice using a vertical shaft can limit the smoke propagation from a fully loaded gasoline tank lorry fire. For this research, scaled model experiments were carried out using a 20 m- long model tunnel with a vertical shaft. A CFD modeling tool was also extensively utilized to investigate the extremely dangerous situation in which a fully loaded gasoline tank lorry is burning inside a long road tunnel.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号