首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   97篇
  免费   2篇
安全科学   3篇
废物处理   8篇
环保管理   9篇
综合类   10篇
基础理论   13篇
环境理论   1篇
污染及防治   37篇
评价与监测   9篇
社会与环境   9篇
  2023年   1篇
  2022年   3篇
  2021年   6篇
  2019年   2篇
  2018年   2篇
  2017年   4篇
  2016年   3篇
  2014年   5篇
  2013年   10篇
  2012年   12篇
  2011年   3篇
  2010年   5篇
  2008年   6篇
  2007年   7篇
  2006年   7篇
  2005年   4篇
  2004年   6篇
  2003年   6篇
  2002年   4篇
  1997年   1篇
  1994年   1篇
  1964年   1篇
排序方式: 共有99条查询结果,搜索用时 109 毫秒
91.
Katsoyiannis A  Samara C 《Chemosphere》2007,67(7):1375-1382
Semipermeable membrane devices (SPMDs) and conventional active sampling methods were used for the sampling of wastewater from the wastewater treatment plant of Thessaloniki, northern Greece. The occurrence of 22 POPs was shown by both sampling methods. The most abundant compounds were heptachlor-exo-epoxide and PCBs-52; -101 and -180. Concentrations of POPs detected by active sampling and those estimated by the SPMDs matched very well in some cases, but significant mismatches were also observed. Regression analysis of the results detected by both methods showed moderate correlations. The highest uptake rate of hydrophobic compounds by SPMDs was observed for analytes with log K(OW) between 5.5 and 6.0. Our data suggest that active and passive sampling are complimentary, and that at least for the outflow of a WWTP, SPMDs could be used for the routine monitoring of compounds that are listed at the Water Framework Directive of the European Commissions.  相似文献   
92.
The purpose of this research was to study the fate and toxicity of triclosan (TCS) in activated sludge systems and to investigate the role of biodegradation and sorption on its removal. Two continuous-flow activated sludge systems were used; one system was used as a control, while the other received TCS concentrations equal to 0.5 and 2mgl(-1). At the end of the experiment, 1mgl(-1) TCS was added in the control system to investigate TCS behaviour and effects on non-acclimatized biomass. For all concentrations tested, more than 90% of the added TCS was removed during the activated sludge process. Determination of TCS in the dissolved and particulate phase and calculation of its mass flux revealed that TCS was mainly biodegraded. Activated sludge ability to biodegrade TCS depended on biomass acclimatization and resulted in a mean biodegradation of 97%. Experiments with batch and continuous-flow systems revealed that TCS is rapidly sorbed on the suspended solids and afterwards, direct biodegradation of sorbed TCS is performed. Regarding TCS effects on activated sludge process, addition of 0.5mgl(-1) TCS on non-acclimatized biomass initially deteriorated ammonia removal and nitrification capacity. After acclimatization of biomass, nitrification was fully recovered and further increase of TCS to 2mgl(-1) did not affect the performance of activated sludge system. The effect of TCS on organic substrate removal was minor for concentrations up to 2mgl(-1), indicating that heterotrophic microorganisms are less sensitive to TCS than nitrifiers.  相似文献   
93.
The aim of this study was to compare two alternative toxicity assessment methods to determine wastewater toxicity and predict treatment plant process upsets. The toxicity of two synthetic organic compounds (triclosan and 4-n-nonylphenol), which are commonly detected in municipal wastewater, and municipal and industrial wastewaters with different heavy metals content were evaluated by the nitrification inhibition assay and bioluminescence toxicity test. Comparison between both assays confirmed that Vibrio fischeri is generally more sensitive than autotrophic bacteria, and, if not calibrated, the bioluminescence method tends to overestimate toxic effects on activated sludge biomass. The nitrification inhibition assay appears to predict plant process upsets more accurately. Both methods showed a significant toxicity decrease through treatment that could be partially attributed to the significant heavy metals removal obtained by primary and secondary treatment. A good correlation for the two assays was obtained, as indicated by a high correlation coefficient (r2 = 0.80).  相似文献   
94.
The objective of this work was to determine the composition and production rate of medical waste from the health care facility of social insurance institute, a small waste producer in Xanthi, Greece. Specifically, produced medical waste from the clinical pathology (medical microbiology) laboratory, the X-ray laboratory and the surgery and injection therapy departments of the health facility was monitored for six working weeks. A total of 240 kg medical solid waste was manually separated and weighed and 330 L of liquid medical waste was measured and classified. The hazardous waste fraction (%w/w) of the medical solid waste was 91.6% for the clinical pathology laboratory, 12.9% for the X-ray laboratory, 24.2% for the surgery departments and 17.6% for the injection therapy department. The infectious waste fraction (%w/w) of the hazardous medical solid waste was 75.6% for the clinical pathology laboratory, 0% for the X-ray laboratory, 100% for the surgery departments and 75.6% for the injection therapy department. The total hazardous medical solid waste production rate was 64 ± 15 g/patient/d for the clinical pathology laboratory, 7.2 ± 1.6 g/patient/d for the X-ray laboratory, 8.3 ± 5.1 g/patient/d for the surgery departments and 24 ± 9 g/patient/d for the injection therapy department. Liquid waste was produced by the clinical pathology laboratory (infectious-and-toxic) and the X-ray laboratory (toxic). The production rate for the clinical pathology laboratory was 0.03 ± 0.003 L/patient/d and for the X-ray laboratory was 0.06 ± 0.006 L/patient/d. Due to the small amount produced, it was suggested that the most suitable management scheme would be to transport the hazardous medical waste, after source-separation, to the Prefectural Hospital of Xanthi to be treated with the hospital waste. Assuming this data is representative of other small medical facilities, medical waste production can be estimated for such facilities distributed around Greece.  相似文献   
95.
96.
Environmental Science and Pollution Research - Over the past three decades, environmental concerns about the water pollution have been raised on societal and industrial levels. The presence of...  相似文献   
97.
Total suspended particle (TSP) concentrations were determined in the Eordea basin (western Macedonia, Greece), an area with intensive lignite burning for power generation. The study was conducted over a one-year period (November 2000–November 2001) at 10 sites located at variable distances from the power plants. Ambient TSP samples were analyzed for 27 major, minor and trace elements. Annual means of TSP concentrations ranged between 47 ± 33 μg m−3 and 110 ± 50 μg m−3 at 9 out of the 10 sites. Only the site closest to the power stations and the lignite conveyor belts exhibited annual TSP levels (210 ± 97 μg m−3) exceeding the European standard (150 μg m−3, 80/779/EEC). Concentrations of TSP and almost all elemental components exhibited significant spatial variations; however, the elemental profiles of TSP were quite similar among all sites suggesting that they are affected by similar source types. At all sites, statistical analysis indicated insignificant (P < 0.05) seasonal variation for TSP concentrations. Some elements (Cl, As, Pb, Br, Se, S, Cd) exhibited significantly higher concentrations at certain sites during the cold period suggesting more intense emissions from traffic, domestic heating and other combustion sources. On the contrary, concentrations significantly higher in the warm period were found at other sites mainly for crustal elements (Ti, Mn, K, P, Cr, etc.) suggesting stronger influence from soil resuspension and/or fly ash in the warm months. The most enriched elements against local soil or road dust were S, Cl, Cu, As, Se, Br, Cd and Pb, whereas negligible enrichment was found for Ti, Mn, Mg, Al, Si, P, Cr. At most sites, highest concentrations of TSP and elemental components were associated with low- to moderate-speed winds favoring accumulation of emissions from local sources. Influences from the power generation were likely at those sites located closest to the power plants and mining activities.  相似文献   
98.
Occurrence and fate of heavy metals in the wastewater treatment process   总被引:19,自引:0,他引:19  
The occurrence and the fate of heavy metals (Cd, Pb, Mn, Cu, Zn, Fe and Ni) during the wastewater treatment process were investigated in the wastewater treatment plant (WTP) of the city of Thessaloniki, northern Greece, operating in the activated sludge mode. For this purpose, wastewater and sludge samples were collected from six different points of the plant, namely, the influent (raw wastewater, RW), the effluent of the primary sedimentation tank (primary sedimentation effluent, PSE), the effluent of the secondary sedimentation tank (secondary sedimentation effluent, SSE), sludge from the primary sedimentation tank (primary sludge, PS), activated sludge from the recirculation stream (activated sludge, AS), and the digested/dewatered sludge (final sludge, FS).

The distribution of metals between the aqueous and the solid phase of wastewater was investigated. Good exponential correlation was found between the metal partition coefficient, logKp, and the suspended solids concentration. The mass balance of heavy metals in the primary, secondary and the whole treatment process showed good closures for all metal species. The relative distribution of individual heavy metals in the treated effluent and the sludge streams indicated that Mn and Cu are primarily (>70%) accumulated in the sludge, while 47–63% of Cd, Cr, Pb, Fe, Ni and Zn remain in the treated effluent.  相似文献   

99.
Environmental Chemistry Letters - Biocides are applied as chemical additives in hydraulic fracturing fluids to control subsurface microbial activity. When biocides are released into the subsurface,...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号