A campaign was conducted to assess and compare the personal exposure in L3 of Tianjin subway, focusing on PM2.5 levels, chemical compositions, morphology analysis, as well as the health risk of heavy metal in PM2.5. The results indicated that the average concentration of the PM2.5 was 151.43 μg/m3 inside the train of the subway during rush hours. PM2.5 concentrations inside car under the ground are higher than those on the ground, and PM2.5 concentrations on the platform are higher than those inside car. Regarding metal concentrations, the highest element in PM2.5 samples was Fe; the level of which is 17.55 μg/m3. OC is a major component of PM2.5 in Tianjin subway. Secondary organic carbon is the formation of gaseous organic pollutants in subway. SEM–EDX and TEM–EDX exhibit the presence of individual particle with a large metal content in the subway samples. For small Fe metal particles, iron oxide can be formed easily. With regard to their sources, Fe-containing particles are generated mainly from mechanical wear and friction processes at the rail–wheel–brake interfaces. The non-carcinogenic risk to metals Cr, Ni, Cu, Zn and Pb, and carcinogenic hazard of Cr and Ni were all below the acceptable level in L3 of Tianjin subway.
Nitrogen evolution was studied during the co-combustion of hydrothermally treated municipal solid wastes (HT MSW) and coal in a bubbling fluidized bed (BFB). HT MSW blending ratios as 10%, 20% and 30% (wt.%) were selected and tested at 700, 800, 900 °C. Emissions of NO and N2O from blends were measured and compared with the results of mono-combustion trials. Moreover, concentrations of precursors like NH3 and HCN were also quantified. The results are summarized as follows: NO emissions were predominant in all the cases, which rose with increasing temperature. The blending of HT MSW contributed to the NO reduction. N2O emissions decreased with temperature rising and the blending of HT MSW also presented positive effects. At 30% HT MSW addition, both NO and N2O emissions showed the lowest values (391.85 ppm and 55.33 ppm, respectively at 900 °C). For the precursors, more HCN was detected than NH3 and both played important roles on the gas side nitrogen evolution. 相似文献
Fresh leachate, generated in municipal solid waste incineration (MSWI) plants, contains various pollutants with extremely high strength organics, which usually requires expensive and complex treatment processes. This study investigated the feasibility of blending treatment of MSWI leachate with municipal wastewater. Fresh MSWI leachate was pretreated by coagulation–flocculation with FeCl3 2 g/L and CaO 25 g/L, plate-and-frame filter press, followed by ammonia stripping at pH above 12. After that, blending treatment was carried out in a full-scale municipal wastewater treatment plant (WWTP) for approximately 3 months. Different operational modes consisting of different pretreated leachate and methanol addition levels were tested, and their performances were evaluated. Results showed that throughout the experimental period, monitored parameters in the WWTP effluent, including COD (<60 mg/L), BOD5 (<20 mg/L), ammonium (<8 mg/L), phosphorus (<1.5 mg/L) and heavy metals, generally complied with the Chinese sewage discharged standard. Under the experimental conditions, a certain amount of methanol was needed to fulfill TN removal. An estimation of the operation cost revealed that the expenditure of blending treatment was much lower than the total costs of respective treatment of MSWI leachate and municipal wastewater. The outcomes indicated that blending treatment could not only improve the treatability of the MSWI leachate, but also reduce the treatment cost of the two different wastewaters. 相似文献
Journal of Material Cycles and Waste Management - Bio-drying has been proved to be a promising method for treatment of MSW (municipal solid waste) and sewage sludge due to its high energy... 相似文献
Scientific interpretation of the relationships between urban landscape patterns and water quality is important for sustainable urban planning and watershed environmental protection. This study applied the ordinary least squares regression model and the geographically weighted regression model to examine the spatially varying relationships between 12 explanatory variables (including three topographical factors, four land use parameters, and five landscape metrics) and 15 water quality indicators in watersheds of Yundang Lake, Maluan Bay, and Xinglin Bay with varying levels of urbanization in Xiamen City, China. A local and global investigation was carried out at the watershed-level, with 50 and 200 m riparian buffer scales. This study found that topographical features and landscape metrics are the dominant factors of water quality, while land uses are too weak to be considered as a strong influential factor on water quality. Such statistical results may be related with the characteristics of land use compositions in our study area. Water quality variations in the 50 m buffer were dominated by topographical variables. The impact of landscape metrics on water quality gradually strengthen with expanding buffer zones. The strongest relationships are obtained in entire watersheds, rather than in 50 and 200 m buffer zones. Spatially varying relationships and effective buffer zones were verified in this study. Spatially varying relationships between explanatory variables and water quality parameters are more diversified and complex in less urbanized areas than in highly urbanized areas. This study hypothesizes that all these varying relationships may be attributed to the heterogeneity of landscape patterns in different urban regions. Adjustment of landscape patterns in an entire watershed should be the key measure to successfully improving urban lake water quality. 相似文献
Conflicts between local people's livelihoods and conservation have led to many unsuccessful conservation efforts and have stimulated debates on policies that might simultaneously promote sustainable management of protected areas and improve the living conditions of local people. Many government‐sponsored payments‐for‐ecosystem‐services (PES) schemes have been implemented around the world. However, few empirical assessments of their effectiveness have been conducted, and even fewer assessments have directly measured their effects on ecosystem services. We conducted an empirical and spatially explicit assessment of the conservation effectiveness of one of the world's largest PES programs through the use of a long‐term empirical data set, a satellite‐based habitat model, and spatial autoregressive analyses on direct measures of change in an ecosystem service (i.e., the provision of wildlife species habitat). Giant panda (Ailuropoda melanoleuca) habitat improved in Wolong Nature Reserve of China after the implementation of the Natural Forest Conservation Program. The improvement was more pronounced in areas monitored by local residents than those monitored by the local government, but only when a higher payment was provided. Our results suggest that the effectiveness of a PES program depends on who receives the payment and on whether the payment provides sufficient incentives. As engagement of local residents has not been incorporated in many conservation strategies elsewhere in China or around the world, our results also suggest that using an incentive‐based strategy as a complement to command‐and‐control, community‐ and norm‐based strategies may help achieve greater conservation effectiveness and provide a potential solution for the park versus people conflict. 相似文献
Global climate change will influence environmental conditions including temperature, surface radiation, soil moisture, and sea level, and it will also significantly impact regional-scale hydrologic processes such as evapotranspiration (ET), precipitation, runoff, and snowmelt. The quantity and quality of water available for drinking and other domestic usage is also likely to be affected by changes in these processes. Consequently, it is necessary to assess and reflect upon the challenges ahead for water infrastructure and the general public in metropolitan regions. One approach to the problem is to use index-based assessment, forecasting and planning. The drought indices previously developed were not developed for domestic water supplies, and thus are insufficient for the purpose of such an assessment. This paper aims to propose and develop a “Metropolitan Water Availability Index (MWAI)” to assess the status of both the quantity and quality of available potable water sources diverted from the hydrologic cycle in a metropolitan region. In this approach, the accessible water may be expressed as volume per month or week (i.e., m3/month or m3/week) relative to a prescribed historical record, and such a trend analysis may result in final MWAI values ranging from ?1 to +1 for regional water management decision making. The MWAI computation uses data and information from both historical point measurements and spatial remote-sensing based monitoring. Variables such as precipitation, river discharge, and water quality changes at drinking water plant intakes at specific locations are past “point” measurements in MWAI calculations. On the other hand, remote sensing provides information on both spatial and temporal distributions of key variables. Examples of remote-sensing images and sensor network technologies are in-situ sensor networks, ground-based radar, air-borne aircraft, and even space-borne satellites. A case study in Tampa Bay, Florida is described to demonstrate the short-term assessment of the MWAI concept at a practical level. It is anticipated that such a forecasting methodology may be extended for middle-term and long-term water supply assessment. 相似文献
Pollutant emissions from co-firing of refuse derived fuel (RDF) and coal were investigated in a vortexing fluidized bed combustor (VFBC). RDF-5 was made of common municipal solid waste (MSW). CaCO3 was injected in the combustor to absorb HCl at 850 °C. The results show that NOx and HCl emissions increase with RDF-5 co-firing ratio. The NOx concentration in flue gas at the bottom of the combustor is higher than that at the top. However, the trend of HCl released is reverse compared with NOx emissions. It was found that the HCl concentration decreases with increasing the molar ratio of Ca/Cl. However, the effect of CaCO3 addition on HCl retention is not significant when the molar ratio of Ca/Cl is higher than 5. The chlorine content in fly ash increases obviously with the molar ratio of Ca/Cl. PCDD/Fs emissions decrease slightly with an addition of CaCO3. In this study incomplete combustion is regarded as the main cause for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) formation. 相似文献
Abstract A computational fluid dynamics technique was used to evaluate the effect of traffic pollution on indoor air quality of a naturally ventilated building for various ventilation control strategies. The transport of street-level nonreactive pollutants emitted from motor vehicles through the indoor environment was simulated using the large eddy simulation (LES) of the turbulent flows and the pollutant transport equations. The numerical model developed herein was verified by available wind-tunnel measurements. Good agreement with the measured velocity and concentration data was found. Twelve sets of numerical scenario simulations for various roof- and side-vent openness and outdoor wind speeds were carried out. The effects of the air change rate, the indoor airflow pattern, and the external pollutant dispersion on indoor air quality were investigated. The control strategies of ventilation rates and paths for reducing incoming vehicle pollutants and maintaining a desirable air change rate are proposed to reduce the impact of outdoor traffic pollution during traffic rush hours. It was concluded that the windward side vent is a significant factor contributing to air change rate and indoor air quality. Air intakes on the leeward side of the building can effectively reduce the peak and average indoor concentration of traffic pollutants, but the corresponding air change rate is relatively low. Using the leeward cross-flow ventilation with the windward roof vent can effectively lower incoming vehicle pollutants and maintain a desirable air change rate during traffic rush hours. 相似文献